• 제목/요약/키워드: Recanalization

Search Result 100, Processing Time 0.027 seconds

Inadvertent Self-Detachment of Solitaire AB Stent during the Mechanical Thrombectomy for Recanalization of Acute Ischemic Stroke : Lessons Learned from the Removal of Stent via Surgical Embolectomy

  • Kang, Dong-Hun;Park, Jaechan;Hwang, Yang-Ha;Kim, Yong-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.360-363
    • /
    • 2013
  • We recently experienced self-detachment of the Solitaire stent during mechanical thrombectomy of acute ischemic stroke. Then, we tried to remove the detached stent and to recanalize the occlusion, but failed with endovascular means. The following diffusion weighted image MRI revealed no significant increase in infarction size, therefore, we performed surgical removal of the stent to rescue the patient and to elucidate the reason why the self-detachment occurred. Based upon the operative findings, the stent grabbed the main thrombi but inadvertently detached at a severely tortuous, acutely angled, and circumferentially calcified segment of the internal carotid artery. Postoperative angiography demonstrated complete recanalization of the internal carotid artery. The patient's neurological deficits gradually improved, and the modified Rankin scale score was 2 at three months after surgery. In the retrospective case review, bone window images of the baseline computed tomography (CT) scan corresponded to the operative findings. According to this finding, we hypothesized that bone window images of a baseline CT scan can play a role in terms of anticipating difficult stent retrieval before the procedure.

A Clinical Study on the Incidental Pregnancies following Tubal Sterilization Surgery (난관불임술후 발생된 임신에 관한 임상적 고찰)

  • Suh, Byung-Hee;Lee, Jae-Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.10 no.2
    • /
    • pp.13-23
    • /
    • 1983
  • In recent days, family planning is not only a problem limitted to our country but an important problem for the while world to solve. Up to present, various methods of sterilization have been developed for population control. When a patient with a previous tubal sterilization by operative method develops any symptoms and signs of pregnancy, we strongly consider it ectopic pregnancy and intrauterine pregnancy. As the cause of sterilization failure, we think that the tubal loop sloughs away and tubal ends either unite and recanalization results or heal and failure of union results in fistula. This present study considered of the 34 cases of ectopic pregnancies and 2 cases of intrauterine pregnancies after tubal sterilization by laparoscopy and Pomeroy's method, at the Dept. of Gynecol. in Kyung Hee University Hospital, during 6 years from Jan. 1977 to Dec. 1982. Authors take result in this study retrospectively. 1. Mean age was 33.7 years for the laparoscopic tubal sterilization group, 31.5 years for the Pomeroy tubal sterilization group. 2. The number of mean gravida and parity at the sterilization was 4.9, 2.8 for the laparoscopic tubal sterilization group, 4.2, 2.2 for the Pomeroy tubal sterilization group, :respectively. 3. The number of mean artificial abortion at the sterilization was all 2.2 for the laparoscopic and Pomeroy tubal sterilization groups. 4. Mean intervals from the tubal surgery to the incidental pregnancy was 3.2 years for the laparoscopic tubal sterilization group, and 3.8 years for the Pomeroy tubal sterilization group. 5. 63.3% of the laparoscopic tubal sterilization group had problem of inadequate tubal ligation, in comparison to having no inadequate problem in the Pomeroy tubal sterilization group. 6. The previous tubal sterilized scar was found to be 6 cases (17.6%) of inner portion, 15 cases (44.4%) of midportion, 13 cases (38.2%) of outer portion at the time of operation. The tubal site of ectopic pregnancy was found to be 23 cases (67.6%) of ampullary portion,S cases ( 4.7%) of isthmic and fimbrial portion, respectively. 7. The causes of table sterilization failure were, in order of frequency, technical error (19 cases), fistula formation (6 cases) and recanalization (5 cases) for the laparoscopic tubal sterilization group and fistula formation (2 cases), technical error (l case), recanalization (l case) fo the Pomeroy tubal sterilization group. 8. As the new applicated contraceptive method in incidental pregnant patient, Authors used 2 gravigard insertion for the two intrauterine pregnancy and 34 Pomeroys' tubal ligation, 2 total abdominal hysterectomy (due to associated pelvic inflammatory disease) for the 36 tubal pregnancy.

  • PDF

Comparative Analysis of Endovascular Stroke Therapy Using Urokinase, Penumbra System and Retrievable (Solitare) Stent

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.5
    • /
    • pp.342-349
    • /
    • 2015
  • Background : Higher reperfusion rates have been established with endovascular treatment for acute ischemic stroke patients. There are limited data on the comparative performance of mechanical thrombectomy devices. This study aimed to analyse the efficacy and safety of the stent retriever device (Solitaire stent) by comparing procedure time, angiographic outcome, complication rate and long term clinical outcome with previous chemical thrombolysis and mechanical thrombectomy using penumbra system. Method : A retrospective single-center analysis was undertaken of all consecutive patients who underwent chemical thrombolysis and mechanical thrombectomy using Penumbra or Solitaire stent retriever from March 2009 to March 2014. Baseline characteristics, rate of successful recanalization (modified Thrombolysis in Cerebral Infarction score 2b-3), symptomatic intracerebral hemorrhage, procedure time, mortality and independent functional outcomes ($mRS{\leq}2$) at 3 month were compared across the three method. Results : Our cohort included 164 patients, mechanical thrombectomy using stent retriever device had a significant impact on recanalization rate and functional independence at 3 months. In unadjusted analysis mechanical thrombectomy using Solitaire stent retriever showed higher recanalization rate than Penumbra system and chemical thrombolysis (75% vs. 64.2% vs. 49.4%, p=0.03) and higher rate of functional independence at 3 month (53.1% vs. 37.7% vs. 35.4%, p=0.213). In view of the interrelationships between all predictors of variables associated with a good clinical outcome, when the chemical thrombolysis was used as a reference, in multiple logistic regression analysis, the use of Solitaire stent retriever showed higher odds of independent functional outcome [odds ratio (OR) 2.62, 95% confidence interval (CI) 0.96-7.17; p=0.061] in comparison with penumbra system (OR 1.57, 95% CI 0.63-3.90; p=0.331). Conclusion : Our initial data suggest that mechanical thrombectomy using stent retriever is superior to the mechanical thrombectomy using penumbra system and conventional chemical thrombolysis in achieving higher rates of reperfusion and better outcomes. Randomized clinical trials are needed to establish the actual benefit to specific patient populations.

Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein (정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료)

  • Kim, Kun-Il;Jo, Tae-Jun;Lee, Jae-Woong;Hong, Ki-Woo;Lee, Won-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.97-102
    • /
    • 2007
  • Background: Endovenous laser treatment has recently been introduced as a less invasive technique, with many good results reported, A 980-nm diode laser was used on the great saphenous vein (GSV) occlusions in patients with varicose veins, due to GSV reflux, and the therapeutic effects analyzed. Material and Method: Between September 2003 and February 2006, 238 patients (332 cases) with GSV reflux underwent endovenous laser treatment with a 980-nm diode laser. Operative procedures were simultaneous endovenous laser treatment and ambulatory phlebectomy. The preoperative clinical findings, postoperative complications and postoperative duplex US follow up results at 1 and 3 months were reviewed. Result: Postoperative complications were ecchymosis in almost cases, paresthesia 68 cases (20.5%) and skin burn in 3 cases (0.9%). Follow up duplex US revealed 26 and 10 cases at 1 and 3 months of GSV reflux or partial recanalization, with therapeutic success rates of 91.3 and 87.9%, respectively. Conclusion: The treatment of GSV occlusion with an endovenous laser is less invasive than traditional GSV stripping, but relatively high recanalization was experienced, possibly due to inadequate laser power, laser fiber pullback speed or an extremely dilated GSV. However, continuous attempts will be required to reduce the recanalization after the procedure, with accurate follow up using duplex US.

Effects of an Infection Control Protocol for Coronavirus Disease in Emergency Mechanical Thrombectomy

  • Eun, Jin;Lee, Min-Hyung;Im, Sang-Hyuk;Joo, Won-Il;Ahn, Jae-Geun;Yoo, Do-Sung;Park, Hae-Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.224-235
    • /
    • 2022
  • Objective : Since the outbreak of the coronavirus disease 2019 (COVID-19) pandemic, neurointerventionists have been increasingly concerned regarding the prevention of infection and time delay in performing emergency thrombectomy procedures in patients with acute stroke. This study aimed to analyze the effects of changes in mechanical thrombectomy protocol before and after the COVID-19 pandemic on procedure time and patient outcomes and to identify factors that significantly impact procedure time. Methods : The last-normal-to-door, first-abnormal-to-door, door-to-imaging, door-to-puncture, and puncture-to-recanalization times of 88 patients (45 treated with conventional pre-COVID-19 protocol and 43 with COVID-19 protection protocol) were retrospectively analyzed. The recanalization time, success rate of mechanical thrombectomy, and modified Rankin score of patients at discharge were assessed. A multivariate analysis was conducted to identify variables that significantly influenced the time delay in the door-to-puncture time and total procedure time. Results : The door-to-imaging time significantly increased under the COVID-19 protection protocol (p=0.0257) compared to that with the conventional pre-COVID-19 protocol. This increase was even more pronounced in patients who were suspected to be COVID-19-positive than in those who were negative. The door-to-puncture time showed no statistical difference between the conventional and COVID-19 protocol groups (p=0.5042). However, in the multivariate analysis, the last-normal-to-door time and door-to-imaging time were shown to affect the door-to-puncture time (p=0.0068 and 0.0097). The total procedure time was affected by the occlusion site, last-normal-to-door time, door-to-imaging time, and type of anesthesia (p=0.0001, 0.0231, 0.0103, and 0.0207, respectively). Conclusion : The COVID-19 protection protocol significantly impacted the door-to-imaging time. Shortening the door-to-imaging time and performing the procedure under local anesthesia, if possible, may be required to reduce the door-to-puncture and door-to-recanalization times. The effect of various aspects of the protection protocol on emergency thrombectomy should be further studied.

The $Outback^{(R)}$ $LTD^{TM}$ Catheter: The Novel Re-Entry Technique in Recanalization of Chronic Inflow Occlusion of the Superficial Femoral Arteries in 3 Cases ($Outback^{(R)}$ $LTD^{TM}$ Catheter를 이용한 표재성 대퇴동맥의 만성동맥폐색증의 성공적인 재개통술: 3예 보고)

  • Kong, Joon-Hyuk;Hur, Jin;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.785-789
    • /
    • 2010
  • The acute technical failure of endovascular treatment of chronic total occlusions is most often due to the inability to re-enter the true lumen after occlusion is crossed in a subintimal plane. True lumen re-entry catheters are very effective at gaining wire passage back to the true lumen and facilitating successful endovascular treatment of chronic total occlusions that would otherwise require open bypass. These case reports describe our initial experiences with a new catheter system (the $Outback^{(R)}$ $LTD^{TM}$ catheter) that is designed to allow fluoroscopically controlled re-entry of the true arterial lumen after subintimal guidewire passage during recanalization procedures of arterial occlusions.

Endovascular Treatment of Ruptured Pericallosal Artery Aneurysms

  • Ko, Jun Kyeung;Kim, Hwan Soo;Choi, Hyuk Jin;Lee, Tae Hong;Yun, Eun Young;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.197-204
    • /
    • 2015
  • Objective : Aneurysms arising from the pericallosal artery (PA) are uncommon and challenging to treat. The aim of this study was to report our experiences of the endovascular treatment of ruptured PA aneurysms. Methods : From September 2003 to December 2013, 30 ruptured PA aneurysms in 30 patients were treated at our institution via an endovascular approach. Procedural data, clinical and angiographic results were retrospectively reviewed. Results : Regarding immediate angiographic control, complete occlusion was achieved in 21 (70.0%) patients and near-complete occlusion in 9 (30.0%). Eight procedure-related complications occurred, including intraprocedural rupture and early rebleeding in three each, and thromboembolic event in two. At last follow-up, 18 patients were independent with a modified Rankin Scale (mRS) score of 0-2, and the other 12 were either dependent or had expired (mRS score, 3-6). Adjacent hematoma was found to be associated with an increased risk of poor clinical outcome. Seventeen of 23 surviving patients underwent follow-up conventional angiography (mean, 16.5 months). Results showed stable occlusion in 14 (82.4%), minor recanalization in two (11.8%), and major recanalization, which required recoiling, in one (5.9%). Conclusion : Our experiences demonstrate that endovascular treatment for a ruptured PA aneurysms is both feasible and effective. However, periprocedural rebleedings were found to occur far more often (20.0%) than is generally suspected and to be associated with preoperative contrast retention. Analysis showed existing adjacent hematoma is predictive of a poor clinical outcome.

Treatment Outcomes with Selective Coil Embolization for Large or Giant Aneurysms : Prognostic Implications of Incomplete Occlusion

  • Jo, Kyung Il;Yang, Na-Rae;Jeon, Pyoung;Kim, Keon Ha;Hong, Seung-Chyul;Kim, Jong Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • Objective : The objectives of this study were to evaluate the immediate and long-term efficacy and safety of coil embolization for large or giant aneurysms. Methods : One hundred and fifty large or giant aneurysm cases treated with endovascular coil embolization between January 2005 and February 2014 at a single institute were included in this study. Medical records and imaging findings were reviewed. Statistical analysis was performed to evaluate prognostic factors associated with major recurrence (major recanalization or rupture) and delayed thromboembolism after selective coil embolization. Results : Procedure-related symptomatic complications occurred in five (3.3%) patients. The mean clinical and radiological follow-up periods were 38 months (range, 2-110) and 26 months (range, 6-108), respectively. During the follow-up period, the estimated recurrence rate was 4.6% per year. Multivariate analysis using Cox regression showed the degree of occlusion to be the only factor associated with recurrence (p=0.008, hazard ratio 3.15, 95% confidence interval 1.34-7.41). The patient's history of rupture in addition to the size and location of the aneurysm were not associated with recurrence in this study. Delayed infarction occurred in eight cases, and all were incompletely occluded. Conclusion : Although immediate postprocedural safety profiles were reasonable, longterm results showed recanalization and thromboembolic events to occur continuously, especially in patients with incomplete occlusion. In addition, incomplete occlusion was associated with delayed thromboembolic complications. Patients with incomplete occlusions should be followed carefully for delayed recurrence or delayed thromboembolic events.

Spinal Dural Arteriovenous Fistulas : Clinical Experience with Endovascular Treatment as a Primary Therapeutic Modality

  • Park, Sung-Bae;Han, Moon-Hee;Jahng, Tae-Ahn;Kwon, Bae-Ju;Chung, Chun-Kee
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.6
    • /
    • pp.364-369
    • /
    • 2008
  • Objective : The aim of this study was to evaluate the efficacy of endovascular therapy as a primary treatment for spinal dural arteriovenous fistula (DAVF). Methods : The authors reviewed 18 patients with spinal DAVFs for whom endovascular therapy was considered as an initial treatment at a single institute between 1993 and 2006. NBCA embolization was considered the primary treatment of choice, with surgery reserved for patients in whom endovascular treatment failed. Results : Surgery was performed as the primary treatment in one patient because the anterior spinal artery originated from the same arterial pedicle as the artery feeding the fistula. Embolization was used as the primary treatment modality in 17 patients. with an initial success rate of 82.4%. Two patients with incomplete embolization had to undergo surgery. One patient underwent multiple embolizations, which failed to completely occlude the fistula but relieved the patient's symptoms. Spinal DAVF recurred in two patients (one collateral development and one recanalization) during the follow-up period. The collateral development was obliterated by repeated embolization, but the patient with recanalization refused further treatment. The overall clinical status improved in 15 patients (83.3%) during the follow-up period. Conclusion : Endovascular therapy can be successfully used as a primary treatment for the majority of patients with spinal DAVFs. Although it is difficult to perform in some patients, endovascular embolization should be the primary treatment of choice for spinal DAVF.

Endovascular Treatment of Wide-Necked Intracranial Aneurysms Using Balloon-Assisted Technique with HyperForm Balloon

  • Youn, Sang-O;Lee, Jae-Il;Ko, Jun-Kyung;Lee, Tae-Hong;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.207-212
    • /
    • 2010
  • Objective : To assess the feasibility, safety, and effectiveness of the balloon-assisted technique with HyperForm balloon in the endovascular treatment of wide-necked intracranial aneurysms. Methods : A total of 34 patients with 34 wide-necked intracranial aneurysms were treated with endovascular coil embolization using balloon-assisted technique with Hyperform balloon. Twenty-nine aneurysms (85.3%) were located in the anterior circulation. The group of patients was comprised of 16 men and 18 women, aged 33 to 72 years (mean : 60.6 years). The size of aneurysms was in the range of 2.0 to 22.0 mm (mean 5.5 mm) and one of neck was 2.0 to 11.9 mm (mean 3.8 mm). The dome to neck ratio was ranged from 0.83 to 1.43 (1.15). Sixteen patients were treated for unruptured aneurysms and the remaining 18 presented with a subarachnoid hemorrhage. Results : In the 34 aneurysms treated by the remodeling technique with HyperForm balloon, immediate angiographic results consisted of total occlusion in 31 cases (91.2%) and partial occlusion in three cases (8.8%). There were five procedure-related complications (14.7%), including two coil protrusions and three thromboembolisms; Except one patient, all were successfully resolved without permanent neurologic deficit. No new bleeding occurred during the follow-up. Twenty patients (59%) underwent angiographic follow-up from 2 to 33 months (mean 9.2 months) after treatment. Focal recanalization with coil compaction of the neck portion was observed in 5 cases (25%). Only one case showed major recanalization and underwent stent-assisted coil embolization. Conclusion : The balloon-assisted technique with Hyperform balloon is a feasible, safe, and effective endovascular treatment of wide-necked cerebral aneurysms.