• Title/Summary/Keyword: Rebars

Search Result 300, Processing Time 0.024 seconds

Bond Performance of Ductile Hybrid FRP Rebar After Chemical Environmental Exposures (고연성 하이브리드 FRP 리바의 화학적 환경 노출 후 부착 성능)

  • Won Jong-Pil;Park Chan-Gi;Seo Jung-Min;Kong Tae-Woong;Sung Sang-Kyoung;Choi Seok-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.333-336
    • /
    • 2004
  • In this study focuses on bond properties of hybrid FRP rebar after chemical environmental exposure. Hybrid FRP rebar bond specimens were subjected to four type of exposure conditions. Bond properties were investigated by direct bond test. Bond test results, hybrid FRP rebars were found to have better bond strength with concrete than currently using GFRP rebar. Also, hybrid FRP rebar had more than about $80\%$ in bond strength of steel rebar.

  • PDF

Studies on the influence of zinc oxide as an inhibitor for the corrosion of mild steel in simulated concrete environments (콘크리트 환경에서 ZnO의 철근 부식 억제에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1873-1875
    • /
    • 2005
  • The effect of zinc oxide as an inhibitor for the corrosion of steel in concrete environment was studied by weight loss measurements, potential-time behaviour and anodic polarization technique. The salient features of the investigation were: in 100% OPC extracts, the passivity of steel was readily destroyed, however extracts containing various concentration of zinc oxide, the passivity of steel was maintained even in the presence of 30,000 ppm of chloride. Alkalinity of concrete was maintained by the addition of zinc oxide. The efficiency of the inhibitor was found to increase with increasing inhibitor concentration. Addition of zinc oxide in the range 3 to 4% by weight of cement was sufficient to protect the rebars.

  • PDF

Experimental Study on the Structural Capacity of the U-flanged Truss Hybrid Beam with Hollow Rebars (중공철근으로 보강한 U-플랜지 트러스 복합보의 구조 내력에 관한 실험연구)

  • Lee, Seong Min;Oh, Myoung Ho;Kim, Young Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.65-72
    • /
    • 2022
  • A typical low and medium-sized neighborhood living facility in reinforced concrete building secures a high floor and pursues an efficient module plan(long span). Accordingly, research on the development of new hybrid beams that can innovatively reduce labor costs such as on-site installation and assembly while securing strength and rigidity is ongoing. In order to verify the structural performance of the U-flanged truss composite beam with newly developed shape, Experiments with various variables are required. Based on the results, this study is to evaluate the strength of U-flanged truss hybrid beam through the flexural strength of the Korea Design Code and experimental values. It was evaluated that nominal flexural strength was 110% to 135% higher than the experimental value.

A Study on the Factors for Revision of the Reinforced Concrete Construction Cost Estimation Standard (철근콘크리트 공사비산정기준 개정요인에 관한 연구)

  • Song, Tae-seok;Ahn, Bang-yul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.198-199
    • /
    • 2022
  • Reinforced concrete is the most widely used construction method for constructing structures. There is a lot of process for constructing Reinforced concrete structures such as installing rebars, molds and support, mixing and placing concrete, and curing. So the reinforced concrete work accounts for a large part of the total construction cost for constructing structure. For this reason a reasonable standard for estimating the cost of reinforced concrete construction has to be established and it will be possible to secure appropriate costs for construction work. In this study, we analyze the revision factors of the standard for estimating the cost of reinforced concrete construction and present them to secure reasonable construction costs.

  • PDF

Investigation of the steel rebar corrosion using embeddable solid state reference electrode in marine environments (해양 환경에서 매립형 고체 기준 전극을 사용한 철근 부식 조사)

  • Subbiah, Karthick;Park, TaeJoon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.57-58
    • /
    • 2022
  • Reinforced concrete (RC) structures play a significant role in the construction industries. An embeddable solid-state reference electrode (ESSRE) was used to evaluate the corrosion status of steel rebar in the concrete of various cover thicknesses that exposed to the maritime environment (3.5 % NaCl) in this study. From the open circuit potential measurement (OCP), the passive state, the corrosion uncertainty, and the 90% probability of corrosion state of the steel rebars in the concrete were monitored by ESSRE. From the electrochemical impedance spectroscopy (EIS) method, severe corrosion was observed at the exposure period of 1510, 1847, 2350, and 3020 h for C10, C15, C20, and C30 concrete, respectively. The results confirm that the ESSRE can be useful to identify the corrosion occurrence and severe corrosion of steel rebar embedded in different cover depth concrete structures.

  • PDF

Micro Computer Tomography Applied Monotonic Pullout Test for Deformed Rebar Bonding Model (이형 철근의 콘크리트 부착 모델 수립을 위한 Micro-CT 활용 단조가력 시험)

  • Jang, Indong;Cho, Junghyun;Yi, Chongku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.192-193
    • /
    • 2020
  • In reinforced concrete adhesion studies, the demolition of the specimen is inevitably involved, and the studies conducted are limited to the macro load-displacement analysis. In order to establish an elaborate model for concrete bonding reinforced rebars, it is necessary to observe the rebar bonding behavior in the in-situ state. In this study, specially manufactured reinforcing bars, micro-UTM and 𝝁-computer tomography (𝝁CT) are used to observe reinforcing bars in the in-situ state. As a result of the monotonic pullout test of the processed reinforcing bar, maximum bond stress were shown to be 16.7MPa, which is slightly higher than the existing 10 to 12 MPa, and then the empty space inside the specimen in which the pullout test was conducted using 𝝁CT was confirmed. Through additional research, the fracture phenomenon of concrete excluding voids will be studied.

  • PDF

Status and Problems of Buildings Neglected for Long Period after Discontinuance of Construction in Jeju (제주도내 공사중단 장기방치 건축물 현황과 문제점)

  • Kim, Doo-Seong;Han, In-Deok;Jang, Myunghoun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.153-154
    • /
    • 2023
  • Neglected buildings for long period can seriously reduce the durability of the building due to rust in rebars and deterioration in concrete quality due to exposure to outside air, and the seriousness of suspended buildings such as safety accidents and social crimes is emerging due to poor management. In this study, various problems such as the occurrence of safety accidents were analyzed through a fact-finding survey of buildings that have not been maintained due to long-term neglect in all areas of Jeju. In order to reuse a building that has been discontinued, the safety of the building structure itself must be checked. After securing safety through durability investigation, construction should be resumed or converted into a normal building through re-purposing, dismantling, remodeling, etc.

  • PDF

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.

Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices (굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동)

  • Chun, Sung-Chul;Lee, Jin-Gon;Ha, Tae-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.275-283
    • /
    • 2012
  • Steel Plate for Rebar Connection was recently developed to splice rebars in delayed slab-wall joints in high-rise building, slurry wall-slab joints, temporary openings, etc. It consists of several couplers and a thin steel plate with shear key. Cyclic loading tests on slab-wall joints were conducted to verify structural behavior of the joints having Steel Plate for Rebar Connection. For comparison, joints with Rebend Connection and without splices were also tested. The joints with Steel Plate for Rebar Connection showed typical flexural behavior in the sequence of tension re-bar yielding, sufficient flexural deformation, crushing of compression concrete, and compression rebar buckling. However, the joints with Rebend Connection had more bond cracks in slabs faces and spalling in side cover-concrete, even though elastic behavior of the joints was similar to that of the joints with Steel Plate for Re-bar Connection. Consequently, the joints with Rebend Connection had less strengths and deformation capacities than the joints with Steel Plate for Re-bar Connection. In addition, stiffness of the joints with Rebend Connection degraded more rapidly than the other joints as cyclic loads were applied. This may be caused by low elastic modulus of re-straightened rebars and restraightening of kinked bar. For two types of diameters (13mm and 16mm) and two types of grades (SD300 and SD400) of rebars, the joints with Steel Plate for Rebar Connection had higher strength than nominal strength calculated from actual material properties. On the contrary, strengths of the joints with Rebend Connection decreased as bar diameter increased and as grade becames higher. Therefore, Rebend Connection should be used with caution in design and construction.

A Study of the Material Properties of Steel Used to Repair the Stupa of State Preceptor Jigwang from Beopcheonsa Temple, Wonju in 1957 (1957년 원주 법천사지 지광국사탑 수리에 사용된 철물(鐵物)의 재료학적 특성 연구)

  • You, Harim;Lee, Jaesung;Lee, Taejong;Park, Heejeoung
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.4
    • /
    • pp.100-117
    • /
    • 2020
  • National Treasure no. 101, the stupa of State Preceptor Jigwang from the Beopcheonsa Temple Site in Wonju has been transferred from place to place and reassembled several times since it was built. In particular, overall dismantling and repair was carried out in 1957 to restore parts damaged by bombing during the Korean War. Documented information on the repair process and materials used at that time does not exist. However, various types of metal materials used for this stupa have been identified during conservation work. Besides clamps anchor bolts, 9mm-thick circular rebars were mainly used for joining the parts of this stupa, while circular rebars and wires of various thicknesses were used for joining the parts with mortar restoration materials. Although deformed bars are typically used for stone pagodas classified as architectural structures, smooth circular rebars were used in this case. In terms of restoration using mortar, material shapes were transformed, bound alternately, and twisted irregularly to improve bonding strength and coherence in order to insert restoration materials and to bolster structural weaknesses. In addition, metallographic analysis showed the material to be hypo-eutectoid steel with low carbon content. Many non-metallic inclusions in the shape of drops of different sizes were included, which do not affect the whole elemental composition due to the very small quantities involved. Qualitative and EPMA analysis of Mn and S, which were not identified by SEM-EDS area analysis, established an even distribution of MnS in crystal grains of the microstructure, regardless of the shape of the samples. It is presumed that secondary homogenization and softening might have been conducted after manufacturing to facilitate the working process. Furthermore, in consideration of properties indicating that the thinner the steel is, the less carbon content contained and the greater the elasticity and elongation, it is judged that restoration work was ordered.