• 제목/요약/키워드: Rebar corrosion

검색결과 242건 처리시간 0.023초

Earthquake response of reinforced concrete frame structures subjected to rebar corrosion

  • Yuksel, Isa;Coskan, Seda
    • Earthquakes and Structures
    • /
    • 제5권3호
    • /
    • pp.321-341
    • /
    • 2013
  • This paper investigates earthquake response of reinforced concrete regular frames subjected to rebar corrosion. A typical four-story reinforced concrete frame is designed according to Turkish Earthquake Code in order to examine earthquake response. Then different levels of rebar corrosion scenarios are applied to this frame structure. The deteriorated conditions as a result of these scenarios are included loss in cross sectional area of rebar, loss of mechanical properties of rebar, loss in bond strength and variations in damage limits of concrete sections. The frame is evaluated using a nonlinear static analysis in its sound as well as deteriorated conditions. The rebar corrosion effect on the structural response is investigated by comparing the response of the frame in each scenario with respect to the sound condition of the frame. The results shows that the progressive deterioration of the frame over time cause serious reductions on the base shear and top displacement capacity and also structural ductility of the corroded frames. The propagation time, intensity, and extensity of rebar corrosion on the frame are important parameters governing the effect of rebar corrosion on earthquake response of the frame.

Effect of Rebar Corrosion on Mechanical Behaviour of RC Structures

  • Yokota, Hiroshi
    • Corrosion Science and Technology
    • /
    • 제4권3호
    • /
    • pp.81-88
    • /
    • 2005
  • The effects of rebar corrosion on the structural behaviour of reinforced concrete structures were discussed based on recent experimental investigation. The load carrying capacity of the deteriorated beams was quantitatively estimated by evaluating the degree of rebar corrosion in terms of the average cross-sectional loss of longitudinal reinforcing bars and bond deterioration between corroded reinforcing bars and concrete.

PSC I형 교량 바닥판의 철근노출 및 부식에 대한 구조적 안전성 분석 (Analysis of Structural Safety for Rebar Exposure and Corrosion in PSC I-Girder Bridge Slab)

  • 한만석;박주현;이종한;민지영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권1호
    • /
    • pp.67-74
    • /
    • 2021
  • 본 논문에서는 노후화된 PSC I형 교량을 대상으로 철근부식에 대한 구조적 안전성을 평가하였다. 대상 PSC I형 교량은 실제 구조물을 참고하여 철근을 배근하고 해석 시 콘크리트의 파괴와 철근의 항복을 고려하였다. 한국시설안전공단 정밀안전진단의 교량 평가 기준을 참고하여 철근노출면적률과 철근부식률로 구분하여 총 32가지의 철근부식 시나리오를 구성하였다. 철근노출은 교량의 바닥판 하부 인장철근이 콘크리트 피복 탈락에 의해 노출된 것으로 가정하였다. 각 시나리오별 해석 결과, PSC I형 교량의 안전율과 내하율은 철근노출면적률과 철근부식률이 증가함에 따라 감소하였다. 철근부식률이 50% 이상일 경우는 모든 철근노출면적률에 대해서 안전성등급을 세밀하게 분석할 필요가 있었으며, 철근부식률 57%이상인 경우는 철근노출면적률에 관계없이 모두 E등급으로 산정되었다. 철근노출면적률 2%에 대해서 상관도 분석을 실시한 결과,철근부식률이 약 55.8% 까지는 A등급, 56.9% 까지는 C등급, 58.5% 까지는 D등급, 58.5% 이상인 경우 E등급으로 평가되었다. 본 연구를 통해 노후화된 교량에 대한 철근부식의 정량적인 구조적 안전성 평가가 필요할 것으로 판단된다.

서울시내 140개 철근콘크리트 교량의 내구성 현황 분석 (Current Status on Durability of 140 RC Bridges in Seoul Metropolitan Area)

  • 이창수;설진성;윤인석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.161-168
    • /
    • 2000
  • A series of in-situ inspection and measurements have been conducted to estimate rebar corrosion incidence of concrete bridges in Seoul metropolitan area. The objectives of this study were to obtain the fundamental data to analysis the causes of rebar corrosion and to establish the repair strategies of deteriorated concrete bridges due to corrosion. The results of this study had been analysed to identify the extent of chloride content and incidence of rebar corrosion by construction ages and by members. After measuring chloride content in concrete, it was concluded that about 76% of all tests on samples from concrete exceed the maximum acceptable limit to risk of chloride-induced corrosion. On the whole, slabs had the most highly chloride content. About 16% of the concrete bridges had a value lower than -350mV (vs. CSE), so it could concluded that the excessive chloride content and carbonation were a major causes of rebar corrosion. Concrete member which carbonation depth penetrates toward rebar was 39% among all tests on samples. The major causes of rebar corrosion were highly chloride content 50%, concrete carbonation 38%, poorly visual condition 6% and etc, 6%.

  • PDF

혼화재 혼입 콘크리트에 매립된 철근의 부식 임계염화물 산정에 관한 실험적 연구 (An Experimental Study on Corrosion Critical Chloride Contents of Rebar Embedded in Concrete with Admixture)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.40-41
    • /
    • 2018
  • The purpose of this study is to compare the amount of critical chloride of rebar embedded in concrete according to the substitution rate of admixture. In order to determine the starting point of corrosion of rebar, electrodes were embedded in concrete, chloride was supplied, and OCP of rebar was observed in real time. The amount of the contaminants in the concrete surrounding the rebar was judged to be the critical corrosion chloride contents of the rebar at the start of the corrosion. As a result of the comparative evaluation, it was confirmed that the critical chloride contents of the rebar decreased with increasing the substitution ratio of the admixture.

  • PDF

Corrosion Inhibition of Steel Rebar in Concrete with the Coated MCI 2022

  • Bezad Bavarian;Lisa Reiner;Kim, Chong Y.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.63-67
    • /
    • 2002
  • The induced chemical and salt solution in water or admixture are originated to the corrosion process of the steeo rebar. These liquids penetrate into concrete as the accompanied by the chemical reaction and cause to attack the steel rebar in concrete. Concrete surfaces which it exposed to deicing, water and sea water is allowed to enter the chlorides in the structures. To prevent from the source of corrosion and deterioration Is subjected to put an end to corrode or reduce to contaminate on the steel rebar. As this reason the MCI 2022 products are applied to the surface of concrete and steel rebar. The concrete samples were made of to the kind of four, i.e. RF, MR, MS, and MM. Corrosion inhibitor is applied to coat on the surface of concrete after it had been cured for 28days. Specimen were immersed in a 3.5% sodium chloride solution. Concrete specimen were tested to determine the changes of the resistance polarization, Rp, over a 22 weeks period. MCI 2022 is significantly shown the corrosion inhibition of steel rebar in 3.5% NaCl solution. In the each different concrete sample, MS and MM is seemed to be better than others. The results are proofed that MCI 2022 is promised to maintain the inhibition of corrosion with high resistance polarization of the steel rebar in concrete.

  • PDF

부식된 철근을 사용한 모르타르의 환경에 따른 부식전위의 거동 (The behavior of corrosion potential in the mortar-embedded)

  • 이상호;한정섭;권순석
    • 한국해양공학회지
    • /
    • 제10권4호
    • /
    • pp.103-108
    • /
    • 1996
  • To syudy the change of prtential in the mortar-embedded precorroded rebar, a half cell method was adapted. The rebar was corroded by the salt spray and then the rebar embedded in the mortar. A saturated copper sulfate feference electrode was used. The corrosion potential of the rebar in the mortar specimen cured in air was increased, whereas that of the rebar cured in water was decreased with aging. The corrosion potential of the rebar in the mortar was decreased with corroded time by the salt spray. As the mortar thickness covered the rebar was increased, the corrosion potential of the rebar in the mortar was increased.

  • PDF

Numerical simulation approach for structural capacity of corroded reinforced concrete bridge

  • Zhou, Xuhong;Tu, Xi;Chen, Airong;Wang, Yuqian
    • Advances in concrete construction
    • /
    • 제7권1호
    • /
    • pp.11-22
    • /
    • 2019
  • A comprehensive assessing approach for durability of reinforced concrete structures dealing with the corrosion process of rebar subjected to the attack of aggressive agent from environment was proposed in this paper. Corrosion of rebar was suggested in the form of combination of global corrosion and pitting. Firstly, for the purposed of considering the influence of rebar's radius, a type of Plane Corrosion Model (PCM) based on uniform corrosion of rebar was introduced. By means of FE simulation approach, global corrosion process of rebar regarding PCM and LCM (Linear Corrosion Model) was regressed and compared according to the data from Laboratoire $Mat{\acute{e}}riaux$ et $Durabilit{\acute{e}}$ des Constructions (LMDC). Secondly, pitting factor model of rebar in general descend law with corrosion degree was introduced in terms of existing experimental data. Finally, with the comprehensive numerical simulation, the durability of an existing arch bridge was studied in depth in deterministic way, including diffusion process and sectional strength of typical cross section of arch, crossbeam and deck slab. Evolution of structural capacity considering life-cycle rehabilitation strategy indicated the degradation law of durability of reinforced arch bridges.

EIS를 이용한 염화물 및 방청제가 첨가된 콘크리트에 매립된 철근의 방식성능 평가에 관한 실험적 연구 (A Experimental Study on the Evaluation of Anti-corrosion Performance of rebar in concrete added chloride and inhibitor using EIS method)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.134-135
    • /
    • 2016
  • To evaluate anti-corrosion performance of rebar in concrete according to the amount of chloride and inhibitor, electrochemical impedance spectroscopy(EIS) method was conducted in this study. For the anti-corrosion performance evaluation according to time, Impedance of rebar in concrete was measured before and after 5 cycle of corrosion acceleration. As a results, The impedance of rebar in concrete added chloride decreased than before corrosion acceleration. However impedance of other specimens was maintained or increased than before corrosion acceleration.

  • PDF

철근콘크리트에 매립된 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Monitoring of Corrosion of Rebar Embedded in Reinforced Concrete)

  • 박장현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.262-263
    • /
    • 2019
  • In this study, a sensor for detecting corrosion of rebar embedded in reinforced concrete structures was fabricated and its performance was verified. In order to monitor the open circuit potential(OCP) of the rebar embedded in reinforced concrete, a concrete embedded solid electrode was constructed as a sensor using MnO2. The OCP of the rebar could be observed using a sensor and a data logger. The decrease of the OCP to -510mV (vs.MnO2) or less was judged to be corrosion of the rebar. Since it is a solid-mediated sensor, it is more stable and durable than an electrode using an aqueous solution, and it is considered that the corrosion state of the rebar can be monitored for a long period of time.

  • PDF