• Title/Summary/Keyword: Real time simulator

Search Result 771, Processing Time 0.029 seconds

The Development of HILS and Test Equipment for Millimeter-Wave (Ka-Band) Seeker's Test and Evaluation (밀리미터파 탐색기 시험 평가를 위한 HILS 및 시험 장비 개발)

  • Song, Sung-Chan;Na, Young-Jin;Yoon, Tae-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • This paper describes the developed HILS and test equipment in order to test the performances of MMW(Millimeter-Wave) seeker which can detect and track a high speed of short-range ballistic missile and aircraft. This system is used to 141 horn antenna array, array switching, and gain and phase control algorithm to simulate various kind of targets and trajectory of high speed and maneuver moving target. In addition, it simulates not only velocity and range for these targets but also clutter and jamming environments. System configuration and implementation and the measurement results of major subsystems such as target motion simulator, simulation signal generator, high speed data aquisition unit, and central control unit are presented. These systems could verify the detection and tracking performance of MMW seeker through dynamic real-time test based on simulation flight scenario.

Field Implementation of Voltage Management System (VMS) into Jeju Power System in Korea

  • Shin, Jeonghoon;Nam, Suchul;Song, Jiyoung;Lee, Jaegul;Han, Sangwook;Ko, Baekkyung;An, Yongho;Kim, Taekyun;Lee, Byungjun;Baek, Seungmook
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.719-728
    • /
    • 2015
  • This paper presents the results of field tests on Voltage Management System (VMS) using hybrid voltage control, which utilizes coordinated controls of various reactive power resources such as generators, FACTS and switched shunt devices to regulate the pilot bus voltage in a voltage control area. It also includes the results of performance test on RTDS-based test bed in order to validate the VMS before installing it in Jeju power system. The main purpose of the system is adequately to regulate the reactive power reserve of key generators in a normal condition with coordination of discrete shunt devices such as condensers and reactors so that the reserves can avoid voltage collapse in emergency state in Jeju system. Field tests in the automatic mode of VMS operation are included in steady-states and transient states. Finally, by the successful operation of VMS in Jeju power system, the VMS is proved to effectively control system voltage profiles in steady-state condition, increase system MVAR reserves and improve system reliability for pre- and post-contingency.

A Verification of Intruder Trace-back Algorithm using Network Simulator (NS-2) (네트워크 시뮬레이터 도구를 이용한 침입자 역추적 알고리즘 검증)

  • Seo Dong-il;Kim Hwan-kuk;Lee Sang-ho
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.1
    • /
    • pp.1-11
    • /
    • 2005
  • Internet has become an essential part of our daily lives. Many of the day to day activities can already be carried out over Internet, and its convenience has greatly increased the number of Internet users. Hut as Internet gains its popularity, the illicit incidents over Internet has also proliferated. The intruder trace-back technology is the one that enables real time tracking the position of the hacker who attempts to invade the system through the various bypass routes. In this paper, the RTS algorithm which is the TCP connection trace-back system using the watermarking technology on Internet is proposed. Furthermore, the trace-bark elements are modeled by analyzing the Proposed trace-back algorithm, and the results of the simulation under the virtual topology network using ns-2, the network simulation tool are presented.

An Experimental Study on Detection of Gas Leakage Position by Monitoring Pressure Values at City Gas Pipeline (압력값 모니터링을 통한 배관 내 가스누출감지에 대한 실험적 연구)

  • Jin, Kyoung-Min;Choi, Gyu-Hong;Lee, Song-Kyu;Chung, Tae-Yong;Shin, Dong-Hoon;Hwang, Seung-Sik;Oh, Jeong-Seok
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.292-297
    • /
    • 2011
  • Gas pipeline safety management and risk prediction are recognized as a very important issue. And the effort to prevent accidents is essential. So, in this study, it was studied through correlation of pressure changes for leak point detection in real-time. It experimented by installing the five leakage valves in the pipe of 378 m and compared the actual leak points with simulation results. The results showed that experimental leak points and the actual leak points have differences within the 6 m. And this technology has to be commercialized by the demonstration in dangerous zone.

Power System Education System using 3-Dimensional Graphic Animation (3차원 그래픽 애니메이션을 이용한 전력계통 교육시스템)

  • Park, In-Kwon;Won, Jong-Ryul;Lee, Jin;Yoon, Yong-Beum
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.593-601
    • /
    • 2001
  • This paper presents an efficient system for power system education using 3-D computer graphics animation in the PC environment. Several power system phenomena are simulated using Real-Time Digital Simulator. Results are transmitted through on-line communication line to PC for graphic animation, and simulated in the 3-D graphics animation. It can immediately reflect user control input and re-simulated this result. The proposed method was tested on both the sub-synchronous resonance phenomena and multi-bus system. It is expected that the proposed method would be helpful for the operator training as well as power system education.

  • PDF

의료용재료의 최근 개발현황

  • 김영하
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 1989
  • The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan`s method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements.

  • PDF

Performance Evaluation of a Differentiated Service Mechanism by Traffic Models and Weight Factor (트래픽 모델과 Weight Factor에 의한 차등 서비스 메커니즘의 성능평가)

  • 전용희;박수영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11C
    • /
    • pp.10-23
    • /
    • 2001
  • It is difficult to satisfy the QoS(Quality of Service) guarantee which is required by real-time application services only with the Best-Effort(BE) service adopted in the current Internet. Therefore, worldwide research is being made on the method of QoS provisioning. Among them, the QoS guarantee mechanism using the Diffserv(Differentiated Service) was discussed in this paper. First we analyzed how the DiffServ performance was affected by traffic models. For this, we performed the research for the random, bursts, and self-similar traffic modeling method. We then designed and implemented an OPNET simulator, and performed the simulation 7d performance evaluation for diverse input parameters. Based on the results of performance evaluation, it was confirmed that QoS guarantee is possible for the EF(Expedited Forwarding) class with the DiffServ function under every environments considered and the service separation between EF and BE(Best Effort) classes is also possible. We also analyzed the performance variation and dynamic behavior of DiffServ mechanism based on the resource allocation between E? and BE classes in WFQ(Weighted Fair Queueing).

  • PDF

A Study on the Development of Prediction Method of Ozone Formation for Ozone Forecast System (오존예보시스템을 위한 오존 발생량의 예측기법 개발에 관한 연구)

  • Oh, Sea Cheon;Yeo, Yeong-Koo
    • Clean Technology
    • /
    • v.8 no.1
    • /
    • pp.27-37
    • /
    • 2002
  • To verify the performance and effectiveness of bilinear model for the development of ozone prediction system, the simulation experiments of the model identification for ozone formation were performed by using bilinear and linear models. And the prediction results of the ozone formation by bilinear model were compared to those of linear model and the measured data of Seoul. ARMA(Autoregressive Moving Average) model was used in the model identification. A recursive parameter estimation algorithm based on an equation error method was used to estimate parameters of model. From the results of model identification experiment, the ozone formation by bilinear model showed good agreement with the ozone formation from the simulator. From the comparison of the prediction results and the measured data, it appears that the method proposed in this work is a reasonable means of developing real-time short-term prediction of ozone formation for an ozone forecast system.

  • PDF

A Study on Design of Vehicle Control System Based on ${\mu}C/OS-II$ (${\mu}C/OS-II$를 적용한 차량용 제어시스템의 설계에 관한 연구)

  • Song, Young-Ho;Lee, Tae-Yang;Park, Won-Yong;Moon, Chan-Woo;Ahn, Hyun-Sik;Jeong, Gu-Min
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.193-197
    • /
    • 2009
  • In this paper, we study on design of vehicle control system which is based on ${\mu}C/OS-II$, We component a electric motor drive system for simulator because the most of vehicle part use electric motor for actuator. We use the XC2287 microcontroller which is often used vehicle body controller because XC2287 guarantee high confidence and durability in vehicle industry. The electric motor control system derive PWM from general I/O port in XC2287 microcontroller. The signal is supplied at electric motor after amplifying that using driver circuit. The user control duty of PWM signal through controlling potentiometer which is connected to XC2287. through that, the user control speed of electric motor. we synchronize both input process via controlling potentiometer and PWM output process using semaphore. we verify porting of ${\mu}C/OS-II$ via experimentation.

  • PDF

Fault Detection Sensitivity of a Data-driven Empirical Model for the Nuclear Power Plant Instruments (데이터 기반 경험적 모델의 원전 계측기 고장검출 민감도 평가)

  • Hur, Seop;Kim, Jae-Hwan;Kim, Jung-Taek;Oh, In-Sock;Park, Jae-Chang;Kim, Chang-Hwoi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.836-842
    • /
    • 2016
  • When an accident occurs in the nuclear power plant, the faulted information might mislead to the high possibility of aggravating the accident. At the Fukushima accident, the operators misunderstood that there was no core exposure despite in the processing of core damage, because the instrument information of the reactor water level was provided to the operators optimistically other than the actual situation. Thus, this misunderstanding actually caused to much confusions on the rapid countermeasure on the accident, and then resulted in multiplying the accident propagation. It is necessary to be equipped with the function that informs operators the status of instrument integrity in real time. If plant operators verify that the instruments are working properly during accident conditions, they are able to make a decision more safely. In this study, we have performed various tests for the fault detection sensitivity of an data-driven empirical model to review the usability of the model in the accident conditions. The test was performed by using simulation data from the compact nuclear simulator that is numerically simulated to PWR type nuclear power plant. As a result of the test, the proposed model has shown good performance for detecting the specified instrument faults during normal plant conditions. Although the instrument fault detection sensitivity during plant accident conditions is lower than that during normal condition, the data-drive empirical model can be detected an instrument fault during early stage of plant accidents.