• 제목/요약/키워드: Real time discharge

검색결과 234건 처리시간 0.026초

Real-time Gap Control for Micro-EDM: Application in a Microfactory

  • Jung, Jae-Won;Ko, Seok-Hoon;Jeong, Young-Hun;Min, Byung-Kwon;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권1호
    • /
    • pp.3-6
    • /
    • 2008
  • Electrical discharge machining (EDM) is one of the most widespread nonconventional machining processes. Recently, a low-power micro-EDM process was introduced using a cylindrical electrode. Since its development, micro-EDM has been applied effectively to micromachining, and because the device setup for this process is simple, it is suitable for a microfactory that minimizes machines to fabricate small products economically in one system. In the EDM process, however, the electrode is also removed along with the workpiece. Therefore, the electrode shape and length vary as machining progresses. In this paper, a control method using a high speed realtime voltage measurement is proposed to regulate the rate and amount of material removed. The proposed method is based on the assumption that the volume of the workpiece removed in a single discharge pulses is nearly constant. The discharge pulses are monitored and controlled to regulate the amount of material removed. For this purpose, we developed an algorithm and apparatus for counting the number of discharge pulses. Electrode wear compensation using pulse number information was applied to EDM milling in a microfactory, in which a slight tilt of the workpiece may occur. The proposed control method improves the machining quality and efficiency by eliminating the inaccuracies caused by electrode wear and workpiece tilt.

가스절연모선(GIB)에서 전자파 방전신호의 모드별 군속도 차이를 이용한 방전위치 산정기법 (Partial Discharge Location Method using Group Velocity Difference of Modes in a Electromagnetic Partial Discharge Signal in Gas Insulated Bus)

  • 구선근;주형준;박기준;한기선;윤진열
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2184-2188
    • /
    • 2007
  • We developed a novel method of partial discharge(PD) location based on the fact that the waveform of PD signal propagate along the GIB (Gas Insulated Bus) is composed of several modes of electromagnetic wave with different group velocities and cut-off frequencies. From the PD waveform, measured at a broadband PD sensor attached on the GIB, we could derive arrival time and frequency components of different modes using the short term Fourier transform or etc. After the group velocities of different modes are calculated, the location of the PD source could be estimated. To show the effectiveness of this new locating method in a real on site application, we used this method to locate the position of a PD source at a 76 m long 345 kV GIB substation. The estimated location of the PD source using the method proposed above was in good agreement with the actual location found from the inspection result of internal component in the GIB with 2.4% of the estimation error.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

Design and Development of Agriculture Drone battery usage Monitoring System using Wireless sensor network

  • Lee, Sang-Hyun;Yang, Seung-Hak;You, Yong-Min
    • International journal of advanced smart convergence
    • /
    • 제6권3호
    • /
    • pp.38-44
    • /
    • 2017
  • Currently, wired gables have been installed or portable storage devices have been installed for data acquisition of flying drone. In this paper, we propose a technology to transmit data wirelessly by sensing information such as battery discharge value, acceleration, and temperature by attaching RF sensor to a drone. The purpose of this paper is to design and develop the monitoring technology of agriculture drone battery usage in real time using RF sensor. In this paper, we propose a monitoring system that can check real time data of battery changed value, temperature, and acceleration during pesticide control activity of agricultural drone.

해상용 항로표지 충·방전조절기의 근거리 모니터링 (Short-range Monitoring of Marine AtoN Charge and Discharge Controller)

  • 예성현;한순희
    • 한국정보통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.933-939
    • /
    • 2015
  • 일반전원이 공급되지 않은 광파표지는 태양광을 이용한 전력공급시스템을 사용하고 있다. 이러한 전력공급시스템에서는 충 방전조절기의 역할이 매우 중요하다. 항로표지의 효과적인 관리를 위해 도입된 IT기술(AIS통신 등)은 광파표지에 전력을 사용하는 장치를 추가하게 됨으로써 충 방전조절기의 중요성이 증가하고 있다. 현재 운용되는 충 방전조절기는 항로표지 내부에 부착되어 해상환경에 따라 점검 및 확인하는데 어려움이 있다. 이를 해결하기 위해서 본 논문에서는 충 방전조절기에 블루투스 모듈을 구성하여 근거리 점검이 가능한 모니터링 시스템을 제안하였다. 제안한 시스템은 도입 비용이 적고, 구성이 간편하여 다양한 항로표지에 응용가능한 장점이 있다. 또한 근거리에서 충 방전조절기의 실시간 상태정보를 확인할 수 있어서 점검 비용을 절감하고, 점검 시 발생 가능한 위험요소를 줄일 수 있다.

미세 방전 가공에서의 방전 펄스 카운팅을 이용한 간극 제어 (Gap Control Using Discharge Pulse Counting in Micro-EDM)

  • 정재원;고석훈;정영훈;민병권;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.499-500
    • /
    • 2006
  • The electrode wear in micro-EDM significantly deteriorates the machining accuracy. In this regard, electrode wear needs to be compensated in-process to improve the product quality. Therefore, there are substantial amount of research about electrode wear. In this study a control method for micro-EDM using discharge pulse counting is proposed. The method is based on the assumption that the removed workpiece volume is proportional to the number of discharge pulses, which is verified from experimental results analyzing geometrically machined volume according to various number of discharges. Especially, the method has an advantage that electrode wear does not need to be concerned. The proposed method is implemented to an actual micro-EDM system using high speed data acquisition board, simple counting algorithm with 3 axis motion system. As a result, it is demonstrated that the volume of hole machined by EDM drilling can be accurately estimated using the number of discharge pulses. In EDM milling process a micro groove without depth variation caused by electrode wear could be machined using the developed control method. Consequently, it is shown that machining accuracy in drilling and milling processes can be improved by using process control based on the number of discharge pulses.

  • PDF

조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구 (Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction)

  • 정철기;장한;이경진
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

방전드릴링에서 홀 관통 평가 방법 (A Method of Hole Pass-Through Evaluation for EDM Drilling)

  • 이철수;최인휴;허은영;김종민
    • 대한산업공학회지
    • /
    • 제38권3호
    • /
    • pp.220-226
    • /
    • 2012
  • The Electric discharge machining (EDM) process is used to minimize the difference between designed feature and machined feature while the most workpiece is removed through the cutting processes. The tiny-deep hole machining and perpendicular wall machining in mold and die are good applications of EDM. Among EDM equipment, the super drill uses the hollowed electrode to eliminate the debris which causes the second discharge with the electrode and degrades the machining quality. Through the hollow, the high pressured discharge oil is supplied to remove the debris together with the spindle rotation. The thin-hollow electrode tends to easily wear out compared to the sold die-sinking electrode and its wear rate is might not allowed to monitor in real time during discharging. Up to now, the wear amount is measured by off line method, which leads machining time to increase because the hole pass-through moment can be check by visual (manually) with the extra tool path. Therefore, this study suggests the attractive method to evaluate the hole pass-through moment in which the gap voltage and z-axis encoder pulse are monitored to predict the moment. The commercial super drill is used to validate the proposed method and the experiment is carried out.

전기적 방법을 이용한 전력용 콘덴서 열화특성 연구 (A Study on the Aging Characteristics of Power Capacitors using Electrical Methods)

  • 김은식;김영욱;김종서;윤철섭;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1998
  • Power capacitors are highly reliable equipment due to their completely enclosed configuration. Aging diagnosis system using partial discharge(PD) and acoustic emission(AE) is being highlighted as a research area for degradation of power capacitors. Their dielectric strength can be however reduced due to some stresses such as over-voltage or thermal degradation of the insulation material during their long period of operation. In this paper, it has been developed to express the AE of the EVENT(average amplitude) and HIT(pulse count) according to the source location. And real time measurement of PD signals for aging diagnosis of power capacitors.

  • PDF

A Study on the Correlation Between the PD Pattern and the Type of Electrical Trees Propagation in the XLPE Insulation for the Underground Power Transmission

  • Lee, Jeon-Seon;Kim, Jeong-Tae;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제11C권2호
    • /
    • pp.12-17
    • /
    • 2001
  • In this work, the correlation between the PD Patterns and the electrical tree propagation has been investigated by use of the specimen removed from the insulation of the real 154 kV XLPE underground power cables. As a result, it could be deduced that the PD pattern regarding electrical trees depends on their type which could be classified into three different distinct groups such as branch-bush mixed. Considering the results of our investigation, if the partial discharge magnitude is only considered for the diagnosis of the cable system, it is possible to draw a wrong decision. Therefore, it is possible to propose that the time characteristics of PD pattern should be taken into account for the diagnosis of the cable system in addition to the conventional $\Phi$-q-n characteristics.