• Title/Summary/Keyword: Real time discharge

Search Result 234, Processing Time 0.041 seconds

Color Removal of Real Textile Wastewater by Sequential Anaerobic and Aerobic Reactors

  • Oh You-Kwan;Kim Yu-Jin;Ahn Yeonghee;Song Seung-Koo;Park Sunghoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.419-422
    • /
    • 2004
  • Textile wastewater from the Pusan Dyeing Industrial Complex (PDIC) was treated utilizing a two-stage continuous system, composed of an upflow anaerobic sludge blanket reactor and an activated Sludge reactor. The effects of color and organic leading rates were studied by varying the hydraulic retention time and influent glucose concentration. The maximum color load to Satisfy the legal discharge limit of color intensity in Korea (400 ADMI, unit of the American Dye Manufacturers Institute) was estimated to be 2,700 $ADMI{\cdot}L^{-1}\;day^{-1}$. This study Indicates that the two-stage anaerobic/aerobic reaction system is potentially useful in the treatment of textile wastewater.

Hydraulic Efficiency measurement of small turbine and example of it's analysis (소수력수차의 효율측정과 분석사례)

  • Kim, Eung-Tae;Jung, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.748-756
    • /
    • 2005
  • The Purpose of this writing is a presentation of small turbine efficiency measuring method, applicable new technology, and several analysis result for real turbine. Measurement methods of hydraulic efficiency written in here are extracted from small turbine applicable international code(IEC, ASME). It includes brief synopsis of 'Current meter method' and 4 other methods and ASFM as a new small turbine applicable technology. And several analysis of test result are for recently performed domestic small turbine result in korea. Through this presentation of extracted code, I hope that it make other small turbine concerner be familiar to perform an efficiency test. for small turbine. And, some analysis of that, make other to feel the importance of efficiency test.

  • PDF

Plasma Uniformity Analysis of Inductively Coupled Plasma Assisted Magnetron Sputtering by a 2D Voltage Probe Array

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.161-168
    • /
    • 2014
  • A real-time monitoring of immersed antenna type inductively coupled plasma (ICP) was done with a homemade 2 dimensional voltage probe array to check the uniformity of the plasma. Measured voltage values with a high impedance voltmeter are close to the floating potential of the plasma. As the substrate carrier was moving into a magnetron sputtering plasma diffusive from a $125mm{\times}625mm$ size cathode, measured results showed reliably separation of plasma into the upper and lower empty space over the carrier. Infra red thermal imaging camera was used to observe the cross corner effect in situ without eroding a target to the end of the usage. 3 dimensional particle trace model was used to analyze the magnetron discharge's behavior.

Thermal characteristics variation of PDP in compliance with dielectric loss

  • Lee, Tae-Ho;Jung, Jae-Chul;Lee, Sang-Kuk;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.265-268
    • /
    • 2009
  • The discharge condition of Plasma display panel(PDP) changes as the display time increases. Imaginary part of permittivity of dielectric material which is related to dielectric loss has been often neglected because of relatively small value compare to that of the real part. The thermal characteristics of PDPs with two different dielectrics has been studied and compared.

  • PDF

Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill (전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정)

  • 김형균;정기봉;고석만;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

A study on the computer diagnosis that apply Neural-Fuzzy algorithm accumulation detection of Partial Discharge signal (광섬유 내의 유도 브릴루앙 산란광을 이용한 초고압전력케이블 열화진단에 관한 연구)

  • Hwang, Kyoung-Jun;Yeoum, Keoung-Tae;Kim, Yong-Kab;Kim, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1558-1559
    • /
    • 2007
  • This study is an application field by using optical fiber. The system to measure sBs from optical fiber is designed, So it can be used as a temperature sensor. by using frequency shift, resulting from temperature changes. the frequency shift is checked by changing temperature from $25^{\circ}C$ to $69^{\circ}C$ with chamber in the laboratory and using 40Km optical fiber. It's also measured by varying the length of optical fiber The program to do the real-time monitoring and analyze the measured data is created to find accurate frequency. It can be used as an optical fiber sensor, which is capable of measuring temperature and distance by using sBs.

  • PDF

Application of a Distribution Rainfall-Runoff Model on the Nakdong River Basin

  • Kim, Gwang-Seob;Sun, Mingdong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.976-976
    • /
    • 2012
  • The applicability of a distributed rainfall-runoff model for large river basin flood forecasts is analyzed by applying the model to the Nakdong River basin. The spatially explicit hydrologic model was constructed and calibrated by the several storm events. The assimilation of the large scale Nakdong River basin were conducted by calibrating the sub-basin channel outflow, dam discharge in the basin rainfall-runoff model. The applicability of automatic and semi-automatic calibration methods was analyzed for real time calibrations. Further an ensemble distributed rainfall runoff model has been developed to measure the runoff hydrograph generated for any temporally-spatially varied rainfall events, also the runoff of basin can be forecast at any location as well. The results of distributed rainfall-runoff model are very useful for flood managements on the large scale basins. That offer facile, realistic management method for the avoiding the potential flooding impacts and provide a reference for the construct and developing of flood control facilities.

  • PDF

A Diagnostic Study of Pulsed Plasma Process for Reactive Deposition (반응성 증착용 펄스 플라즈마 공정의 진단)

  • Joo, Jung-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.168-173
    • /
    • 2012
  • A real-time monitoring of an immersed antenna type inductively coupled plasma (ICP) was done with optical emission spectroscopy (OES) to check the reports that sputtered atom density is decreasing as the ICP power is increased. At 10 mTorr pressure of Ar, Mg was sputtered by a bipolar pulsed power supply into 2 MHz ICP which has an insulator covered 2.5 turn antenna. Emitted light was collected in two different positions: above the target and inside the ICP region. With 100 W of Mg sputtering power, the intensities of Mg I (285.06 nm), Mg II (279.48 nm), Ar I (420.1 nm) were increased constantly with ICP power from 100 W to 600 W. At 500 W, the intensity of $Mg^+$ exceeded that of Mg under PID controlled discharge voltage of 180 V. The ratio of Mg II/Mg I was increased from 0.45 to 2.71 approximately 6 times.

Successful Management of Eosinophilic Bronchopneumopathy in a Dog

  • Kim, Sol;Seo, Kyoungwon;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.38 no.6
    • /
    • pp.269-273
    • /
    • 2021
  • A dog was presented with a cough, dyspnea, nasal discharge, gagging, and exercise intolerance. The dog showed leukocytosis, peripheral eosinophilia, and an increase C-reactive protein. The radiographic findings noted bronchointerstitial infiltration, intrathoracic lymphadenopathy, and soft tissue opacity mass. Computed tomography findings showed thickening of the bronchus and bronchiole. Also, peri-bronchial consolidation and generalized intrathoracic lymphadenopathy was present. On blind bronchoalveolar lavage and pulmonary cytology, there were significantly increased eosinophils. Canine pulmonary respiratory pathogens from a real-time polymerase chain reaction analysis was negative. Consequently, the dog was diagnosed with eosinophilic bronchopneumopathy. Clinical signs improved significantly within a few days after treatment with an oral corticosteroid.

Development of Looped Rating Curve at Hwawon Station (화원 수위관측소 지점의 고리모양 수위-유량 관계곡선 작성)

  • Kang Shin-Uk;Lee Sang-Ho;Hwang Man-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.487-494
    • /
    • 2006
  • The flood discharge on the rising limb of a hydrograph at Hwawon station greatly differs from the flood discharge on the falling limb for the same stage. When there is such a big hysteresis, there can be a significant amount of errors in the rated discharge obtained from a simple rating curve. To reduce errors in rated discharges, a looped rating curve was established for Hwawon station in the Nakdong River. In order to compute the deviation between real discharges and simply rated discharges, a simple rating curve was established using the stage and discharge data from the results of a hydraulic channel routing. The relationship between the discharge deviation ${\Delta}Q$ and a product of B and ${\Delta}h/{\Delta}t$ was analysed, where B is the channel topwidth; ${\Delta}h$ is the stage increment; At is the time increment. Strong relation between ${\Delta}Q$ and $B{\Delta}h/{\Delta}t$ was found. The discharges calculated from the relationship show differences by 10 % or less for the 7 observations out of 11 observations in 1997 whose stages exceeds 7 m. The observed discharges for the stages over 9 m in 1998 also show small difference with the discharges estimated from the loop rating curve. Looped rating curve is recommended, instead of the simple rating curve to reduce the errors of rated discharges for gauging stations like Hwawon, which has relatively large loop width.