• Title/Summary/Keyword: Real samples

Search Result 1,170, Processing Time 0.031 seconds

Fast Coordinate Conversion Method for Real-time Weather Radar Data Processing

  • Jang, Bong-Joo;Lim, Sanghun;Kim, Won
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • The coordinate system conversion of weather radar data is a basic and important process because it can be a factor to measure the accuracy of radar precipitation rate by comparison with the ground rain gauge. We proposed a real-time coordinate system conversion method that combines the advantages of the interpolation masks of SPRINT and REORDER to use tables of predetermined radar samples for each interpolated object coordinate and also distance weights for each precomputed sample. Experimental results show that the proposed method improves the computation speed more than 20~30 times compared with the conventional method and shows that the deterioration of image quality is hardly ignored.

Real-time Spectroscopic Methods for Analysis of Organic Compounds in Water

  • Kim, Chihoon;Ji, Taeksoo
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.336-341
    • /
    • 2019
  • This paper proposes an optical system where the organic compound content in water is determined by using an ultraviolet (UV) LED (280 nm) and photodetector. The results obtained by the proposed prototype LED spectroscopy system, which includes a single photodetector and two parallel sample holders, are calculated by applying partial least square regression; the values are highly correlated with the actual concentrations of potassium hydrogen phthalate solutions, with an adjusted coefficient of determination about 0.996. Moreover, the total organic carbon values derived from the UV-Vis spectrometer of real samples (lake, river and sea water) differed little from those obtained by the LED spectroscopy. We confirm that the fast, sensitive, and compact LED sensor system can be readily configured for real-time monitoring of organic compounds in water.

Real-time Sign Language Recognition Using an Armband with EMG and IMU Sensors (근전도와 관성센서가 내장된 암밴드를 이용한 실시간 수화 인식)

  • Kim, Seongjung;Lee, Hansoo;Kim, Jongman;Ahn, Soonjae;Kim, Youngho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.329-336
    • /
    • 2016
  • Deaf people using sign language are experiencing social inequalities and financial losses due to communication restrictions. In this paper, real-time pattern recognition algorithm was applied to distinguish American Sign Language using an armband sensor(8-channel EMG sensors and one IMU) to enable communication between the deaf and the hearing people. The validation test was carried out with 11 people. Learning pattern classifier was established by gradually increasing the number of training database. Results showed that the recognition accuracy was over 97% with 20 training samples and over 99% with 30 training samples. The present study shows that sign language recognition using armband sensor is more convenient and well-performed.

Application of the melanocortin 1 receptor (MC1R) gene for discrimination of Hanwoo from Holstein beef using real-time polymerase chain reaction (PCR)

  • Ra, Do-Kyung;Lee, Sung-Mo;Park, Eun-Jeong;Lee, Jung-Goo
    • Korean Journal of Veterinary Service
    • /
    • v.30 no.4
    • /
    • pp.557-562
    • /
    • 2007
  • This study was carried out to discriminate Hanwoo from the milking and hybrid cattle by detection of MC1R gene related to bovine hair color. One hundred sixty six samples were collected from the abattoir (n = 106) and local market (n = 60). The beef from abattoir were originated from Hanwoo (n=27), Holstein (n=29), Hybrid (n=45) and imported cattle (n=5), respectively. The beef from market consisted of Hanwoo (n=36), Holstein (n=7) and imported ones (n=17). Commercialized screening kit (Kogenebiotec, Korea) was used for MC1R gene analysis. As a result, Hanwoo was discriminated from Holstein. However, 9 of 45 hybrid and 11 of 22 imported beef samples were indistinguishable from Hanwoo. It could be explained by second generation of crossing of Hanwoo with Holstein or the cattle with silver or yellow hair. This results suggest that additional tests as well as MC1R gene detection be needed to confirm Hanwoo beef among cattle beef.

Real-Time Detection of Residual Free Chlorine and pH in Water Using a Microchannel Device

  • Kim, Sam-Hwan;Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.368-374
    • /
    • 2011
  • A microfluidic device for real-time monitoring of residual free chlorine and pH in water based on optical absorption is proposed. The device consists of a serpentine micromixer for mixing samples with a reagent, and a photodiode and light emitting diode(LED) for the detection of light absorbance at specific wavelengths, determined for specific reagent combinations. Spectral analyses of the samples mixed with N, N'-diethyl-p-phenylenediamine(DPD) reagent for chlorine determination and bromothymol blue(BTB) for pH measurement are performed, and the wavelengths providing the most useful linear changes in absorbance with chlorine concentration and pH are determined and used to select the combination of LED and photodiode wavelengths for each analyte. In tests using standard solutions, the device is shown to give highly reproducible results, demonstrating the feasibility of the device for the inexpensive and continuous monitoring of water quality parameters with very low reagent consumption.

Spectrofluorimetric determination of EDTA with Cu(II)-tiron chelate (Cu(II)-tiron 킬레이트를 이용한 EDTA 분광형광법 정량)

  • Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.231-235
    • /
    • 2011
  • A spectrofluorimetric method for the determination of EDTA in real samples such as mayonnaise, powder detergent and cleansing cream with tiron (4,5-dihydroxy-1,3-benzenedisulfonic acid) as a fluorimetric reporter was developed. When tiron is chelated with Cu(II), the fluorescent intensity is decreased by a quenching effect. However, when Cu(II)-tiron chelate reacts with EDTA, fluorescent intensity is increased as tiron is released. Several experimental conditions such as pH of the sample solution, the amount of Cu(II), the amount of tiron, heating temperature and heating time were optimized. Fe(III) interfered more seriously than any other ions, interference of Fe(III) could be disregarded, because Fe(III) was scarcely contained in selected real samples. The linear range of EDTA was from $8.0{\times}106{-8}\;M$ to $2.0{\times}10^{-6}\;M$. With this proposed method, the detection limit of Fe(III) was $5.2{\times}10^{-8}\;M$. Recovery yields of 92.7~99.3% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of EDTA.

Real-time Assay of Toxic Lead in In Vivo Living Plant Tissue

  • Ly, SuwYoung;Kim, Nack Joo;Youn, Minsang;Kim, Yongwook;Sung, Yeolmin;Kim, Dohoon;Chung, Tackhyun
    • Toxicological Research
    • /
    • v.29 no.4
    • /
    • pp.293-298
    • /
    • 2013
  • A method of detecting lead was developed using square wave anodic stripping voltammetry (SWASV) with DNA-carbon nanotube paste electrode (CNTPE). The results indicated a sensitive oxidation peak current of lead on the DNA-CNTPE. The curves were obtained within a concentration range of 50 $ngL^{-1}-20mgL^{-1}$ with preconcentration time of 100, 200, and 400 sec at the concentration of $mgL^{-1}$, ${\mu}gL^{-1}$, and $ngL^{-1}$, respectively. The observed relative standard deviation was 0.101% (n = 12) in the lead concentration of 30.0 ${\mu}gL^{-1}$ under optimum conditions. The low detection limit (S/N) was pegged at 8 $ngL^{-1}$ ($2.6{\times}10^{-8}M$). Results showed that the developed method can be used in real-time assay in vivo without requiring any pretreatment and pharmaceutical samples, and food samples, as well as other materials requiring water source contamination analyses.

Development of non-destructive testing method to evaluate the bond quality of reinforced concrete beam

  • Saleem, Muhammad;Almakhayitah, Abdulmalik Mohammed
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.313-323
    • /
    • 2020
  • Non-destructive tests are commonly used in construction industry to access the quality and strength of concrete. However, till date there is no non-destructive testing method that can be adopted to evaluate the bond condition of reinforced concrete beams. In this regard, the presented research work details the use of ultra-sonic pulse velocity test method to evaluate the bond condition of reinforced concrete beam. A detailed experimental research was conducted by testing four identical reinforced concrete beam samples. The samples were loaded in equal increments till failure and ultra-sonic pulse velocity readings were recorded along the length of the beam element. It was observed from experimentation that as the cracks developed in the sample, the ultra-sonic wave velocity reduced for the same path length. This reduction in wave velocity was used to identify the initiation, development and propagation of internal micro-cracks along the length of reinforcement. Using the developed experimental methodology, researchers were able to identify weak spots in bond along the length of the specimen. The proposed method can be adopted by engineers to access the quality of bond for steel reinforcement in beam members. This allows engineers to carryout localized repairs thereby resulting in reduction of time, cost and labor needed for strengthening. Furthermore, the methodology to apply the proposed technique in real-world along with various challenges associated with its application have also been highlighted.

Spectrophotometric Determination of Cadmium and Copper with Ammonium Pyrrolodinedithiocarbamate in Nonionic Tween 80 Micellar Media

  • Lee, Seung Gwon;Choe, Hui Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.5
    • /
    • pp.463-466
    • /
    • 2001
  • The determination of Cd2+ and Cu2+ with ammonium pyrrolidinedithiocarbamate (APDC) in Tween 80 micellar media has been studied. The UV-visible spectrum of Cd(PDC)2 complex in Tween 80 media had more sensitivity tha n in chloroform. Although the UV-visible spectrum of the Cu(PDC)2 complex in Tween 80 media had somewhat less sensitivity than that in chloroform, absorbance data of Cu2+ were more reproducible in Tween 80 media. The Cd(PDC)2 and Cu(PDC)2 complexes were very stable at pH 7.0 for up to 100 minutes and could be quantitatively chelated if APDC were added to the sample solution more than 30 times the moles of Cd2+ and Cu2+ . The optimum concentration of Tween 80 was 0.1%. The calibration curves of Cd(PDC)2 and Cu(PDC)2 complexes with good linearity were obtained in 0.1% Tween 80 media. The detection limits of Cd2+ and Cu2+ were 0.0493 ㎍mL-1 and 0.0393 ㎍mL-1 , respectively. Recovery yields of Cd2+ and Cu2+ ions in the spiked real samples were almost 100%. Based on experimental results, this proposed method could be applied to the rapid and simple determination of Cd2+ and Cu2+ in real samples.

Investigation of Consumers' Knowledge and Preference towards Functional Cosmetics (기능성 화장품에 대한 소비자 인지도와 선호도 조사)

  • Choi, Sun-Hye;Hong, Ran-Hee
    • Journal of the Korean Society of Fashion and Beauty
    • /
    • v.3 no.2 s.2
    • /
    • pp.55-64
    • /
    • 2005
  • The purpose of this study is to investigate consumers' knowledge and preference towards functional cosmetics. Through the beauty advisors' surveys, their own selling styles and consumer behaviors recognized by beauty advisors were analyzed. It was intended to help extend and strengthen the functional cosmetic market which has continued to grow rapidly since the approved goods under cosmetic law in 2001. For this study, the data was collected through questionnaires the professional consumer counselors confirmed from Korean women over the age. of twenty old living in the Seoul and Kyoungki areas. After pre-research was implemented on 45 women, 328 samples were analyzed as final samples. In addition,46 samples, which were collected through the questionnaires from beauty advisors were analyzed. Samples were analyzed by frequency, percentage, T-test, ANOVA using the SPSS program. The results of study were as follows: First consumers recognized whether functional cosmetics or not. According to the beauty advisor's surveys, consumers regard the functional cosmetic boundary as being wider than real functional cosmetic boundary according to cosmetic law. So, there is a gap between consumers' opinions and real law. Second, regarding the purchasing channels, the largest channel is the cosmetic store. As far as consumers are concerned the most important factor when buying cosmetics, is the suitability of their own skin types. The second factor is product quality and the third factor is price. Functional cosmetics non-experienced group are more concerned with price compared to experienced group. Related to purchasing products, functional cosmetics experienced group buy set products compared to non-experienced group buy one product. Third, the ultraviolet filter cosmetics portion is the largest in the functional cosmetics market the second largest portion is bleaching cosmetics and the third largest portion is the anti-senility cosmetics. However, Most preferred by consumers is the anti-senility cosmetics. Moreover, preference for ultraviolet filter cosmetics is the least. Finally, the level of satisfaction for functional cosmetics is high and dissatisfaction is low. Consumers feel that beauty advisors are simply pushing high priced products without recognizing the consumers' real needs. In conclusion, to develop the functional cosmetic market continually in the future, it needs to extend various products and advertise them until consumers are more aware.

  • PDF