• 제목/요약/키워드: Reagent strip

검색결과 24건 처리시간 0.019초

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • 제16권3호
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권1호
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성 (Usability of Urinary Reagent Strips in Diagnosis of Meningitis)

  • 정진영;박상규
    • Pediatric Infection and Vaccine
    • /
    • 제4권2호
    • /
    • pp.265-270
    • /
    • 1997
  • 목 적 : 뇌수막염은 소아기에 비교적 자주보는 감염병중의 하나이며 조속한 진단과 치료가 중요하다. 진단에는 뇌척수액의 화학적, 생물학적 검사가 필요하다. 그러나 그 결과를 알기까지 시간이 소요되며 또 검사시설을 이용할 수 없는 지역도 있다. 저자들은 뇨검사 시험지로 뇌척수액의 백혈구수, 당량 및 단백량을 측정하고 결과를 분석하여 그 유용성을 알아보았다. 대 상 : 1997년 4월 1일부터 1997년 7월 31일까지 울산대학교병원 소아과에 뇌수막염을 의심하여 입원한 69명을 대상으로 하였다. 방 법 : 환아들의 뇌척수액을 채취하여 두부분으로 나누었다 일부는 즉시 뇨검사 시험지(Combur-10 Test M)로 척수액의 당량, 단백량과 백혈구수를 측정하였고, 다른 일부는 실험실에서 현미경을 이용한 세포수를 측정하고 당과 단백질에 대한 생화학적 검사를 하여 두 결과를 비교하였다. 결 과 : 무균성 뇌막염으로 진단된 69명의 환자에서, 1) 뇌척수액내 백혈구수의 뇨검사 시험지를 이용한 검사결과는 음성, 10~25, 75, 500개/${\mu}L$로 구분되었으며 각군들은 20명, 34명, 14명, 1명이었고, 이들군에 해당되는 현미경을 이용한 실제 뇌척수액내 백혈구수는 각각 $18.4{\pm}25.^{\circ}C$개/${\mu}L$, $50.5{\pm}68.5$개/${\mu}L$, $163.8{\pm}132.2$개/${\mu}L$, 240개/${\mu}L$이였다. 2) 단백질에 대한 뇨검사 시험지는 음성, 30, 100mg/dL로 구분되었으며 각군들은 각각 8명, 58명, 3명이었고, 이군들에 해당되는 환아들의 생화학적 검사방법에 의한 측정치는 각각 $14.0{\pm}5.5mg/dL$, $31.3{\pm}11.5mg/dL$, $66{\pm}27.2mg/dL$이었다. 3) 당에 대한 뇨검사 시험지는 정상, 50, 100, 300mg/dL로 구분되었으며 각군들은 각각 2명, 62명, 4명, 1명이었고 이들군에 해당되는 생화학적 검사 방법에 의한 측정치는 각각 $76.5{\pm}10mg/dL$, $58.2{\pm}8.8mg/dL$, $70.5{\pm}10.8mg/dL$, 70mg/dL이 었다. 결 론 : 뇨검사 시험지($Combur^{10}$ test strip)를 이용하여 뇌척수액의 단백질, 당 및 백혈구수를 간단하게 측정하여 조기에 뇌수막염을 진단할 수 있고, 무균성 뇌막염과 세균성 뇌막염을 감별하여 초기에 항생제를 쓸것인지 보류할 것인지를 판단하는데 도움을 줄 수 있으며, 시행하기가 간편하고 시간이 소요되지 않으며 특히 검사시설이 갖추어 있지 않은 곳에서 일하는 의료인들에게 유용하리라 생각된다.

  • PDF

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권4호
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

건습시약 스트립을 사용한 임상화학분석장치 개발[I] (Development of Clinical Chemistry Analyzer with the Dry Reagent Strip(I))

  • 유동주;정태화;민홍기;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권4호
    • /
    • pp.299-306
    • /
    • 1992
  • For quantitative measurement of reflected light from a clinical diagnostic scrip, a prototype of reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate re(leclance parameters. The strop was illuminated at $45^{\circ}C$ through optical fiber and the intensity of reflected light was determined at rectangulat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/dl about glucose, a saturation state of absorbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

가시 반사광을 이용한 임상화학 분석장치 개발의 기초연구 (A Study on Clinical Chemistry Analyzer Development by Using the Reflected Visible Light)

  • 유동주;정태화;민홍기;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.144-147
    • /
    • 1992
  • In this paper, we study about reflectance photometer for measuring teflectance changes on reagent strip material after applying of a liguid sample. To obtain more accurate reflectance parameter, the strip loader and cassette is designed. The system is designed to work with IBM personal computer. As the experimental results, reflectance level measured of korean standard color paper and shows a exponentially proportion to brightness of paper. A diagnostic strip for total protein is applied to our system and shows a good correlation in a physically protein concentration range.(up to 500 mg/dl).

  • PDF

미세 다수공 타입의 네일파일 제조용 퍼퍼레이팅 금형 개발 (Development of Perforating Die for Manufacturing Fine Multi-perforated type Nail Files)

  • 김세환
    • 한국산학기술학회논문지
    • /
    • 제5권4호
    • /
    • pp.309-314
    • /
    • 2004
  • 네일 파일(nail file)을 제조할 때 재료는 강판(두께 0.5㎜)을 사용하고 가공방법은 외형형상을 만들고 Φ 0.8-Φ 1.0㎜의 구멍을 약 300여개 뚫어 완성한다. 이들의 가공방법은 에칭(etching)에 의존하여 제조원가의 33%를 에칭비가 차지하고 있으므로 제조원가의 상승원인이 되고 에칭시 부식제(etching reagent)의 잔류도 환경 친화적이 못되며 재료가 강판이기 때문에 제품에 녹(rust)이 생기므로 이들의 문제점을 해결하고자 다음과 같이 연구개발을 수행하였다. 제품의 녹 방지를 할수 있는 적합한 재질 선택 방법을 고찰하고, 에칭 가공방법을 사용하지 않고 금형을 이용한 프레스 가공으로 교체하기 위하여 프레스 스탬핑시의 스트립 레이아웃(strip layout)기법을 연구개발하고, 금형 부품 중에서 작업 중 절손이 빈번한 보통의 표준펀치를 퀼형의 펀치로 개발 하므로써 프로그레시브 퍼퍼레이팅 금형(progressive perforating die)을 개발하게 되었다.

  • PDF

스트립을 이용한 뇨분석 시스템의 퍼지 분류기 및 자동 튜닝 구현 (Implementation of Fuzzy Classifier and Automatic Turning for Urine Analyzer System using the Strip)

  • 김건우;이승진;김광년;최병철;예수영;전계록;조진욱;김재형;이권순
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.141-142
    • /
    • 1998
  • The urine analysis system implemented to measuring the primary color reaction of urinalysis strip. Fuzzy classifier based on fuzzy theory implemented so as to classify of 9 items in the urinalysis strip and proposed the automatic turning algorithm of mambership function in the fuzzy classifier to progress the reproduction of classify. To evaluation of clinical capability, the fuzzy classifier and automatic turning algorithm apples to standard strip and standard reagent.

  • PDF

Vanillin의 신미량검출법 (제1보)

  • 이상섭;김용덕
    • 약학회지
    • /
    • 제3권1호
    • /
    • pp.48-50
    • /
    • 1957
  • The micro-assay methods of vanillin have been shown quite few, though several methods have been introduced for determination. A new sensitive micro-determination of vanillin, applying the yellow color reaction of vanillin and anillin, is shown in this paper. The absorption maximum of the yellow coloring matter, 4-Oxy-3-methoxy-henzal aniline, was 435 mu. The one dimensional ascending paper chromatographic method is applyed for isolation of vanillin from the mixed sample. The microdetection of vanillin is studied only in this paper. Vanillin was detected by the yellow spot on paper trip by the coloring reagent of aniline after several hours paper strip chromatographic at the following condition; paper strip ................ 2.5 X 35cm Whatman Filter Paper No.2 developing Solvent ......... petroleum-benzene-methanol n-butanol-water coloring agent ............. aniline. The Rf-value on petroleum benzene and methanol was 0.63 and that on n-butanol and water was 0.90. The minimum detectable amount of vanillin by this method was 10 micrograms. It is recommendable, if interference substances as aromatic aldehydes present, that the application of this aniline reaction and Foline Denis reaction on the same paper chromatogram is appreciable.

  • PDF

과산화효소를 이용한 백혈구 측정용 뇨 검사지 제조에 관한 연구 (Development of Urine Strip for Detection of Leukocytes in Urine using Peroxidase)

  • 송은영;이홍수;김희정;김종완;최인성;변시명;정태화
    • 대한의생명과학회지
    • /
    • 제2권2호
    • /
    • pp.199-209
    • /
    • 1996
  • 백혈구에 존재하는 과산화 효소를 이용하여 뇨 중 백혈구의 수를 간접적으로 측정하는 새로운 방법의 뇨 검사지를 개발하였다. 과산화 수소원으로서 포도당 산화효소와 포도당을, 색 원체로서 tetramethylbenzidine을 처리하여 백혈구 측정용 뇨 검사지를 제조하였으며 검출한계는 10cells/${mu}l$ (5 cells/hpf)이었다. 개발된 백혈구 측정용 뇨 검사지로 뇨를 분석하였을 때 뇨 1${mu}l$당 10-25 cells의 백혈구가 존재할 경우에는 2분내에 연녹색을, 75-250 상에 cells/${mu}l$에서는 녹색을 보였고 500 cells/${mu}l$ 이상에서는 녹청색을 보였다. 172명의 환자뇨를 대상으로 뇨중 백혈구 수치를 현미경 측정 결과와 본 연구에서 개발한 백혈구 측정용 뇨 검사지와 현재 수입 시판 중인 미국의 A사 제품과 B사 제품으로 분석 비교한 결과 좋은 상관관계를 보였다. 이와 같은 평가분석을 통하여 볼 때 본 연구에서 개발한 백혈구 측정용 뇨 검사지는 에스터라아제를 이용한 백혈구 측정용 뇨 검사지와 함께 뇨중 백혈구를 스크리닝 하는데 효과적임을 알 수 있었다.

  • PDF