Chip Implementation of 830-Mb/s/pin Transceiver for LPDDR2 Memory Controller (LPDDR2 메모리 컨트롤러를 위한 830-Mb/s/pin 송수신기 칩 구현)

  • Jong-Hyeok, Lee;Chang-Min, Song;Young-Chan, Jang
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.659-670
    • /
    • 2022
  • An 830-Mb/s/pin transceiver for a controller supporting ×32 LPDDR2 memory is designed. The transmitter consists of eight unit circuits has an impedance in the range of 34Ω ∽ 240Ω, and its impedance is controlled by an impedance correction circuit. The transmitted DQS signal has a phase shifted by 90° compared to the DQ signals. In the receive operation, the read time calibration is performed by per-pin skew calibration and clock-domain crossing within a byte. The implemented transceiver for the LPDDR2 memory controller is designed by using a 55-nm process using a 1.2V supply voltage and has a maximum signal transmission rate of 830 Mb/s/pin. The area and power consumption of each lane are 0.664 mm2 and 22.3 mW, respectively.

Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager

  • Yang, Jeong-Gyu;Park, Hee-Duk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.11
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, we proposed real-time relative radiometric calibration processing method for SWIR(Short Wavelength Infra-Red) sensor using 'Hyper-Spectral Imager'. Until now domestic research for Hyper-Spectral Imager has been performing with foreign sensor device. So we have been studying hyper spectral sensor device to meet domestic requirement, especially military purpose. To improve detection & identify capability in 'Hyper-Spectral Imager', it is necessary to expend sensing wavelength from visual and NIR(Near Infra-Red) to SWIR. We aimed to design real-time processor for SWIR sensor which can control the sensor ROIC(Read-Out IC) and process calibrate the image. To build Hyper-Spectral sensor device, we will review the SWIR sensor and its signal processing board. And we will analyze relative radiometric calibration processing method and result. We will explain several SWIR sensors, our target sensor and its control method, steps for acquisition of reference images and processing result.

Study on Automatic Mixing of Nutrient Solution Using ion Electrodes for Closed-Loop Hydroponics (이온전극을 이용한 순환식 양액 자동 조제에 관한 연구)

  • 김민규;류관희;장유섭;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.425-432
    • /
    • 2002
  • This study was carried out to develop an automatic mixing system of nutrient solution for closed-loop hydroponics using ion electrodes. The results of the study are summarized as follows: 1. It appeared that ion-electrodes had not to be soaked into nutrient solution for a long time since it was much less durable than EC or PH sensors. Once ion-electrodes were soaked into real nutrient solution for a long time, they became unstable. 2. ion measurement modules, which were able to sample recirculated nutrient solution and easily wash and dry ion-electrodes, were developed in order to use ion-electrodes continuously. 3. The results of calibration tests on three kinds of ion electrodes presented that the time required to read measurement data was over 30 seconds. Using the calibration data the regression equations for the ion electrodes were developed. 4. An automatic nutrient-solution mixing system using the three kinds of ion electrodes was developed and then its accuracy was examined. The control errors of the mixing system using ion electrodes were in the range of 9.8 to 12%.

A Remote Measurement of Water Level Using Narrow-band Image Transmission (협대역 영상전송을 이용한 원격 수위 계측시스템)

  • Kim, Ki-Joong;Lee, Nam-Ki;Han, Young-Joon;Hahn, Hern-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.54-63
    • /
    • 2007
  • To measure water levels from remote cites using a narrowband channel, this paper developed a difference image based JPEG communication scheme and a water level measurement scheme using the sparsely sampled images in time domain. In the slave system located in the field, the images are compressed using JPEG after changed to difference images, among which in a period of data collection those showing larger changes are sampled and transmitted. To measure the water level from the images received in the master system which may contain noises caused by various sources, the averaging scheme and Gaussian filter are used to reduce the noise effects and the Y axis profile of an edge image is used to read the water level. Considering the wild condition of the field, a simplified camera calibration scheme is also introduced. The implemented slave system was installed at a river and its performance has been tested with the data collected for a month.

New In-Orbit Pixel Correction Method

  • Kim Youngsun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Chang Young-Jun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.604-607
    • /
    • 2005
  • All CCD pixels do not react uniformly even if the light of same radiance enters into the camera. This comes from the different camera optical characteristics, the read-out characteristics, the pixel own characteristics and so on. Usually, the image data of satellite camera can be corrected by the various image-processing methods in the ground. However, sometimes, the in-orbit correction is needed to get the higher quality image. Especially high frequency pixel correction in the middle of in-orbit mission is needed because the in-orbit data compression with the high frequency loss is essential to transmit many data in real time due to the limited RF bandwidth. In this case, this high frequency correction can prevent have to have any unnecessary high frequency loss. This in-orbit correction can be done by the specific correction table, which consists of the gain and the offset correction value for each pixel. So, it is very important to get more accurate correction table for good correction results. This paper shows the new algorithm to get accurate pixel correction table. This algorithm shall be verified theoretically and also verified with the various simulation and the test results.

  • PDF

A Biosensor for the Rapid Detection of the Fungicide Iprovalicarb Residuess (살균제 Iprovalicarb 잔류물의 신속한 검출을 위한 바이오센서)

  • Cho, Han-Keun;Kim, Woon-Ho;Kyung, Kee-Sung;Lee, Eun-Young
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.440-447
    • /
    • 2007
  • In this study, a biosensor was developed using an enzyme-linked immunosorbent assay (ELISA) to rapidly measure the fungicide iprovalicarb residues in agricultural products. The biosensor was designed to include micro-pumps and solenoid valves for fluid transport, a spectrophotometer cuvet as a reaction chamber, a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. The rate of change in optical density of the cuvet was read as final signal output. Micro-pumps were evaluated to investigate their delivery capability, the highest values of the error and the coefficient of variation were 4.3% and 4.6% respectively. As the incubation period was reduced from 15 minutes to 11 minutes to shorten the total processing time, the sensor sensitivity was decreased as the antibody dilution ratio was reduced to a half. The maximum usable period of the coated cuvet was found to be two days with 1% error limit. To predict the concentration of the iprovalicarb residue in agricultural products, a linear calibration model was obtained with r-square values of 0.992 for potato and 0.985 for onion. In validation test for the samples of potatoes and onions against the high performance liquid chromatography, very high correlation values were obtained as 0.996 and 0.993 respectively. Using the cuvet immobilized with antigen, it took 21-minutes for the biosensor to complete the measuring process of the iprovalicarb residues.