• 제목/요약/키워드: Reactor stability

Search Result 345, Processing Time 0.026 seconds

Preparation, Characterization, and Catalytic Applications of Graphene-palladium Nanocomposites

  • Hong, Yeong-Guk;Yu, Se-Hui;Park, Jun-Beom
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.262-262
    • /
    • 2012
  • Modifications of graphenes have been studied for catalytic applications due to their advantages such as high surface area, conductivity and thermal stability. In this research, individual graphene oxide (GO) sheets were exfoliated from graphite using Hummers and Offeman method. Pd nano-particles were deposited on the GO surface using Pd2+ ion exchange where hydroxyl groups on the GO act as nucleation sites of Pd nanoparticles and their dispersions. The thermal treatments of the Pd-GO in H2 flow produced Pd-Graphene nanocomposites. Their catalytic performances in Sonogashira reaction were investigated. Morphological and chemical structures of the GO, Pd-GO, and Pd-Graphene were investigated using FT-IR, XRD, TEM, STEM, and XPS. The catalytic performances have been investigated using microwave reactor.

  • PDF

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations (자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발)

  • 이종일
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.339-344
    • /
    • 2002
  • Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the immobilized XYO increased with the temperature ($19.0 - 29.0^{circ}C$) and sample injection volume ($75-250\muL$) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

Fabrication of Metallic Tantalum Powder by Magnesium-gas Reduction of Tantalum Oxide (탄탈륨 산화물의 마그네슘 가스환원에 의한 탄탈륨 금속분말 제조)

  • Lee, Dong-Won
    • Journal of Powder Materials
    • /
    • v.25 no.5
    • /
    • pp.390-394
    • /
    • 2018
  • Metallic tantalum powder is manufactured by reducing tantalum oxide ($Ta_2O_5$) with magnesium gas at 1,073-1,223 K in a reactor under argon gas. The high thermodynamic stability of magnesium oxide makes the reduction reaction from tantalum oxide into tantalum powder possible. The microstructure after the reduction reaction has the form of a mixture of tantalum and magnesium oxide, and the latter could be entirely eliminated by dissolving in weak hydrochloric acid. The powder size in SEM microstructure for the tantalum powder increases after acid leaching in the range of 50-300 nm, and its internal crystallite sizes are observed to be 11.5 to 24.7 nm with increasing reduction temperatures. Moreover, the optimized reduction temperature is found to be 1,173 K as the minimum oxygen concentration is approximately 1.3 wt.%.

Plasma Technology of Coal Gasification

  • Karpenko, E.I.;Messerle, V.E.;Lockwood, F.;Ustimenko, A.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.3
    • /
    • pp.7-11
    • /
    • 2001
  • Utility boiler operators seeking to gain the greatest economic advantage from their units are faced with three challenges, namely the obligatory light-up fuel costs, the additional expense of supplementary fuel firing should they wish to use a cheaper fuel that may be beyond the original burner manufacturer’s stability and combustion performance assurances and the immediate environmental impact of both. The novel use of plasma arc technology can provide a solution to these challenges. This paper introduces the work being undertaken through a joint collaboration between the EU, Kazahkstan and Russia in order to develop a tried and tested engineering methodology and a mathematical based application and sensitivity analysis approach for the design and optimisation stage of these plasma devices that, as a consequence, their assist in their universal introduction.

  • PDF

Deposition of DLC film by using an FCVA system with a magnetic mirror and characterization of its material properties (거울형 자계 구조를 갖는 진공 여과 아크 증착법을 이용한 다이아몬드상 탄소 박막의 증착 및 물성 분석)

  • PARK, Chang-Kyun;UHM, Hyun-Seok;SEO, Soo-Hyung;PARK, Jin-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1717-1719
    • /
    • 2000
  • DLC films are deposited by using an FCVA deposition system with a mirror-type magnetic field configuration. Permanent magnets and: magnetic yokes around the cathode have been observed to enhance the mobility of arc spots on the cathode and the stability of arc plasma, Effects of reactor pressures and substrate biases on structural properties of DLC films deposited are investigated. The results show that the highest $sp^{3}/sp^{2}$ fraction is obtained when the films are deposited at a pressure of $3{\times}10^4$ Torr and a bias voltage of - 50 V. The variation of the structural properties due to thermal stress up to 500$^{\circ}C$ is also examined.

  • PDF

Carbon Contained Ammonium Diuranate Gel Particles Preparation in Mid-process of High-temperature Gas-cooled Reactor Fuel Fabrication

  • Jeong, Kyung Chai;Cho, Moon Sung
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.175-181
    • /
    • 2016
  • This study investigates the dispersibility of carbon in carbon contained ammonium diuranate (C-ADU) gel particles and the characteristics of C-ADU gel liquid droplets produced by the vibrating nozzle and integrated aging-washing-drying equipment. It was noted that the excellent stability of carbon dispersion was only observed in the C-ADU gel particle that contained carbon black named CB 10. ADU gel liquid droplets containing carbon particles with the excellent sphericity of approximately 1,950 mm were then obtained using an 80-100-Hz vibrating nozzle system. Dried C-ADU gel particles obtained by the aging-washing-drying equipment were thermal decomposed until $500^{\circ}C$ at a rate of $1^{\circ}C/min$ in an air or in 4% $H_2$ gas atmosphere. The thermally decomposed C-ADU gel particles showed 24% weight loss and a more complicated profile than that of ADU gel particles.

APPLICATION OF STABLE EMULSIONS TO LIPASE IMMOBILISED MEMBRANE REACTORS FOR KINETIC RESOLUTION OF RACEMIC ESTERS

  • Giorno, Lidietta;Na, Li;Drioli, Enrico
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.65-68
    • /
    • 2003
  • The paper discusses the use of stable emulsion, prepared by membrane emulsification technology, to improve the enantiocatalytic performance of immobilised lipase in multiphasic membrane reactors. The production of optical pure (S)-naproxen from racemic naproxen methyl ester has been used as model reaction system. The enzyme was immobilised in the sponge layer (shell side) of capillary polyamide membrane with 50 kDa cut-off, The O/W emulsion, containing the substrate in the organic dispersed phase, was fed to the enzyme membrane reactor from shell-to-lumen. The results evidenced that lipase maintained stable activity during all the operation time (more than 250 hours), showing an enantiomeric excess (96 $\pm$2%) comparable to the free enzyme (98 $\pm$ 1%) and much higher compared to similar lipase-loaded membrane reactors used in two-separate phase systems (90%). The study showed that immobilised enzymes can achieve high stability as well as high catalytic activity and enantioselectivity.

  • PDF

A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field (고방사선장내 작업 로봇용 이중 방사선 감지 시스템)

  • Lee Nam-Ho;Cho Jai-Wan;Kim Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.

A Study on the Load Flow Program for 765[㎸] Substation Simulator (765[㎸] 변전소 시뮬레이터를 위한 조류계산 프로그램에 관한 연구)

  • 여상민;김철환;이종포
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.201-206
    • /
    • 2003
  • Power system is analyzed by three methods of load flow, fault calculation, and voltage stability. Among there, load flow is calculated to flow of power in power in system at steady state. But, load flow is difficult to analyze to flow of power in substation, because power flow frequently alter by various equipments such as circuit bleaker, disconnect switch and shunt reactor. Particular, in 765[㎸] system, because of form of 1.5GB for stable operation, structure of substation has been very complex. In this paper, we describe technique for application of load flow algorithm in simulator for 765[㎸] substation. For this technique, we built each database for various equipments and considered form of 1.5GB Data as form of bus and line, for application of load flow, are acquired from built database, and then calculate load flow in substation. And. results of load flow are outputted in screen of operator console program.

Application of Self Tuning Fuzzy Controller for System Stability Improvement (시스템 안정도 개선을 위한 자기조정 퍼지제어기 적용)

  • Hur, Dong-Ryol;Joo, Seok-Min;Kim, Hai-Jai
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.60-63
    • /
    • 2002
  • This paper presents a control approach for designing a self tuning fuzzy controller for SVC system, A SVC constructed by a Fixed Capacitor and a Thyristor Controlled Reactor is designed and implemented to improve the damping of a synchronous generator, as well as controlling the system voltage, The proposed parameter self tuning algorithm of fuzzy controller is based on the steepest decent method using two direction vectors which make error between inference values of fuzzy controller and output values of the specially selected PSS reduce steepestly, The related simulation results show that the proposed fuzzy controller is more powerful than the conventional ones.

  • PDF