• 제목/요약/키워드: Reactor operating parameter

검색결과 49건 처리시간 0.027초

원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구 (Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant)

  • 박종혁;최광희;이상국;박종은
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

Neutronic analysis of control rod effect on safety parameters in Tehran Research Reactor

  • Torabi, Mina;Lashkari, A.;Masoudi, Seyed Farhad;Bagheri, Somayeh
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1017-1023
    • /
    • 2018
  • The measurement and calculation of neutronic parameters in nuclear research reactors has an important influence on control and safety of the nuclear reactor. The power peaking factors, reactivity coefficients and kinetic parameters are the most important neutronic parameter for determining the state of the reactor. The position of the control shim safety rods in the core configuration affects these parameters. The main purpose of this work is to use the MTR_PC package to evaluate the effect of the partially insertion of the control rod on the neutronic parameters at the operating core of the Tehran Research Reactor. The simulation results show that by increasing the insertion of control rods (bank) in the core, the absolute values of power peaking factor, reactivity coefficients and effective delayed neutron fraction increased and only prompt neutron life time decreased. In addition, the results show that the changes of moderator temperature coefficients value versus the control rods positions are very significant. The average value of moderator temperature coefficients increase about 98% in the range of 0-70% insertion of control rods.

Identification of the Relationship between Operating Conditions and Polymer Qualities in a Continuous Polymerization Reactor

  • Jeong, Boong-Goon;Yoo, Kee-Youn;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.501-506
    • /
    • 1998
  • A mathematical model is developed to describe the relationship between the manipulated variables (e.g. jacket inlet temperature and feed flow rate) and the important qualities (e.g conversion and weight average molecular weight (Mw)) in a continuous polymerization reactor. The subspace-based identification method for Wiener model is used to retrieve from the discrete sample data the accurate information about both the structure and initial parameter estimates for iterative parameter optimization methods. The comparison of the output of the identified Wiener model with the outputs of a non-linear plant model shows a fairly satisfactory degree of accordance.

  • PDF

원자력발전소 비상디젤발전기 상태감시 기술 적용 연구 (Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant)

  • 최광희;박종혁;박종은;이상국
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

리액터 기동 유도발전기의 동작 특성 해석 (Operating Characteristic Analysis of the Induction Generator by the Reactor Starting)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.138-142
    • /
    • 2014
  • In general, the voltage stability of induction generator is lower than synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used little by little in small hydroelectric power station rather than 1000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the penetration of the induction generator, it is necessary to present a method of reducing inrush current. In this study, we suggested that it is possible to present a reactor startup method, by applying the parameter to reduce the voltage drop.

무수마레인산 생산을 위한 고정층 촉매 반응기 설계 (Design of the Fixed-Bed Catalytic Reactor for the Maleic Anhydride Production)

  • 윤영삼;구은화;박판욱
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.467-476
    • /
    • 1999
  • 공기에 의한 n-butane의 산화로부터 무수마레인산을 합성하는 고정층 촉매 반응기의 거동을 조사하였다. 대류-확산-반응기구로 묘사되는 고정층 촉매반응기의 거동은 Langmuir-Hinshelwood형의 반응속도식 및 비정상상태 이차원 유사균일상 모델을 적용 조사하였다. 예측모델은 Sharma의 pilot-plant 실험 결과인 단일층 반응기의 축방향 온도 및 수율 분포에 대한 최적적합을 통한 최적매개변수 추정에 의해 구성하였다. 또한 예측모델은 단일층 반응기와 통일한 수율 및 전화율을 생성시킬 수 있도록 모사된 불균열활성의 이중층 반응기가 열점에서 $8.96^{\circ}C$ 낮은 온도 상승을 일으켰다. 단일과 이중층 반응기의 가능한 조업조건 (냉매온도, 반응물의 농도, 온도 및 유량)변화에 대한 매개변수 감응도를 조사한 결과 동일한 조업 조건하에서 이중층 반응기가 단일층 반응기에 비해 더 넓은 조업범위는 물론 전화율 및 수율이 다소 높게 나타났다.

  • PDF

간헐폭기법에 의한 돈사 폐수 처리에 관한 연구 (A Study on the Treatment of Swine Wastewater by Using Intermittently Aerated Activated Sludge Process)

  • 양태두;이미경;정윤진
    • 상하수도학회지
    • /
    • 제12권4호
    • /
    • pp.86-96
    • /
    • 1998
  • In this study, an intermittently aerated activated sludge process, modified process from conventional activated sludge process, was developed to treat high strength swine wastewater, which has been blamed as major pollutant for stream pollution. Therefore, the optimum cycle for oxic and anoxic period, SRT, and OLR were studied as design parameters. The effects of different time interval for oxic and anoxic period on nitrification and denitrification were examined by operating two reactors with 60/60min and 60/90min as oxic/anoxic period. Although the reactor with 60/60min showed complete denitrification of $NO_x-N$ generated during oxic period, the reactor with 60/90min showed incomplete nitrification due to the inactivity of nitrifier by accumulated $NH_3-N$ toxicity during anoxic period. Therefore, it is recommended to operate same interval for oxic and anoxic period. In order to determine the optimum cycle for oxic/anoxic period, four different reactors with 30/30, 60/60, 90/90 and 120/120min were examined. The reactor operation with 90/90min was optimum to get the most stable results in this study. However, the optimum cycle for oxic and anoxic period should be changed with characteristics of influent wastewater and operating conditions. According to lie operation results of three reactors with SRT of 15, 20 and 30days. The reactor with 2Odays SRT showed best removal efficiency of T-N. The optimum OLR would be $2.5Kg\;COD/m^3/day$ which showed the most stable nitrification and denitrification. Since characteristics of influent wastewater in the real system has a severe fluctuation, so it is very difficult to determine each interval for oxic and anoxic period. Therefore, ORP curves, describing the change of oxidation/reduction potential in reactor, can be used as a control parameter for automatic control of oxic and anoxic period. In other words, bending point (Nitrate Knee) of ORP curve during anoxic period could be used as a starting point of oxic period.

  • PDF

현장수준의 축산폐수처리에 있어서 계절별 농도 및 온도변화에 따른 분해반응계수 및 온도보정계수의 산정 (Assessment of Degradation Rate Coefficient and Temperature Correction Factor by Seasonal Variation of Concentration and Temperature in Livestock Wastewater Treatment in Field Scale)

  • 박석환
    • 한국환경보건학회지
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 1996
  • This study was performed to calculate the degration rate coefficient, operating parameters to meet the effluent standards, and the temperature adjustment coefficients to each parameter of pollution by seasonal variation of concentration and temperature of influent in livestock wastewater treatment by sequencing batch reactor process in field scale. The followings are the conclusions that were derived from this study. 1. In the field, temperature of livestock wastewater in reactor was 20.3$\circ$C in summer and 6.0$\circ$C in winter. The ratio of BOD:TKN: T-P in influent was 100:80:7. BOD loadings in winter and spring were 0.26 and 0.43 kg $BOD/m^3$ day, respectively. Those in summer and fall were 0.25 and 0.13 kg $BOD/m^3$ day, respectively. 2. The degradation rate coefficient for TKN was larger in summer and fall in which temperature was high than that in which temperature was high than that in winter and spring in which concentration was high. On the contrary, the phosphorus uptake rate was larger in winter and spring than that in summer and fall. 3. The hydraulic retention time in winter and spring was longer than that in summer and fall. Especially, in order to meet the standard for TKN of 120 mg/l in winter in which temperature of wastewater was 6.0$\circ$C, as the MLSS concentration was increased from 4, 000 to 7, 000 mg/l, the hydraulic retention time was increased from 212 to 121 hours. But, in order to shorten that less than 121 hours for the economical wastewater treatment, countermeasure to increase temperature of wastewater in the reactor should be considered. 4. the temperature adjustment coefficients for BOD, $COD_{Mn}$, TKN and T-P were 1.0241, 1.0225, 1.0541 and 1.0495, respectively. Namely, the treatment of TKN was most sensitively affected by temperature. For the purpose of the effective removal of nitrogen and phosphorus which are sensitive to temperature, it is necessary to keep the temperature of livestock wastewater more than 20$\circ$C which is the temperature of it in summer.

  • PDF

울진1,2호기 출력최적화 및 증기발생기 교체가 주급수 제어계통 안정도에 미치는 영향연구 (Research on a Stability of Feedwater Control System after Stretched Power Uprate and Replacement Steam Generator for Ulchin Units 1&2)

  • 윤덕주;김인환;이재용
    • 한국압력기기공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.14-20
    • /
    • 2012
  • Full load rejection capability of nuclear power plant depends primarily on steam dump capacity (SDCAP) and steam generator level control capability. Recently, Ulchin Units 1&2 have performed stretched power uprate (SPU) and replacement steam generator (RSG) projects, which increase the power by 4.5 percent. They change major design or operating parameters and especially reduces steam dump capacity at full power due to increase of the steam flow. The reduction of SDC after SPU results in degradation of heat removal capability in full load rejection transients. Therefore, we should perform evaluation to determine whether reactor trips occur in large load rejection transients. Uchin Units 1&2 have experienced full load rejection (FLR) three times from 2004 to 2010. Operating data from the plant occurrence of FLR at Ulchin Units 1&2 showed that steam generator (SG) level transients were limiting in point of reactor trip. However the plant had never reached reactor trip in the FLR and successfully continued in house load operation. The parameters and setpoints for the SG will be changed if the SG is replaced. Therefore, we evaluated the appropriateness of steam dump, main feedwater and steam generator water level control system preventing the plant from reactor trip in case of FLR by the parameter sensitivity study whether SG water level operated smoothly after SPU and RSG projects.

연속식 MMA/MA 공중합 반응기의 정상상태 및 동특성 해석 (Analysis of steady-states and dynamic characteristics of a continuous MMA/MA copolymerization reactor)

  • 박명준;안성모;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.309-312
    • /
    • 1997
  • The dynamic characteristics of a continuous MMA/MA free-radical solution copolymerization reactor were studied. A mathematical model was developed and kinetic parameters which had been estimated in the previous work were used. With this model, bifurcation diagrams were constructed with various parameters as the bifurcation parameter to predict the region of stable operating conditions and to enhance the controller performance. It was shown that the steady-state multiplicity existed over wide ranges of residence time and jacket inlet temperature. Periodic solution branches were found to emanated from Hopf bifurcation points. Under certain conditions isola was also observed, which would result in poor performance of feedback controllers.

  • PDF