• 제목/요약/키워드: Reactive power sensitivity

검색결과 71건 처리시간 0.028초

전압안정도 개선을 위한 무효전력 제어

  • 김건중;김원겸;정태호;이상중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.422-425
    • /
    • 1991
  • This paper presents the effect of the voltage proximity index for the voltage collpase in power systems. The reactive generation limits are considered for the determination of the voltage proximity index. This paper also shows how the VAR investment ranking order works by the sensitivity index(proximity index). Simulation has carried out with the IEEE 14 bus system and has shown the voltage proximity index working well.

  • PDF

수도권 순동 무효전력 확보를 위한 FACTS 협조제어 시스템 온라인 설치 (Installation of MFC(Multiple FACTS Coordinated control) On-line System for the Spinning Reserve of a Reactive Power in Metropolitan Area)

  • 장병훈;문승필;하용구;전웅재
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2131-2134
    • /
    • 2010
  • In this paper, the on-line system schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control system of FACTS devices, MFC on-line system calculates the optimal set point(Vref, Qrev) of FACTS devices using the coordinated control algorithm with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. As the test, MFC(Multiple FACTS Coordinated control) on-line system will be installed in Korea power system.

대규모 전려계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구 (FACTS Site Selections in Large Power Systems using Subtransmission System Reduction)

  • 장병훈;추진부;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1429-1433
    • /
    • 1999
  • This paper proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive power has been used to determine the location of shunt type FACTS device, but there is a difficulty to finding a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

Rib 도파로 기반 집적 마흐젠더 간섭계 센서 (An Integrated Mach-Zehnder Interferometric Sensor based on Rib Waveguides)

  • 추성중;박정호;신현준
    • 대한전자공학회논문지SD
    • /
    • 제47권4호
    • /
    • pp.20-25
    • /
    • 2010
  • 평판형 rib 도파로의 설계 및 공정기술을 바탕으로 632.8 nm에서 동작하는 집적 마흐젠더 간섭계 센서(Mach-Zehnder interferometric sensor)를 제작하였다. 단일모드와 높은 감도의 두 가지 조건을 고려하여 실리카 계열($SiO_2-SiO_xN_y-SiO_2$) rib 도파로를 설계하였고 박막증착, 사진제판, RIE (Reactive Ion Etching)와 같은 반도체 공정들을 이용해 그 기하학적 구조를 구현하였다. 제작된 rib 도파로의 광출력을 cut-back방법으로 분석한 결과, 약 4.82 dB/cm의 전파손실을 측정하였다. 동시에 크롬 식각방지 층 공정을 도입하여 마흐젠더 간섭계 칩 위에 감지영역(sensing zone)을 형상화할 때 발생하는 코어 층 손상을 방지하였다. 제작된 마흐젠더 간섭계 센서를 이용한 증류수/에탄올 혼합물 굴절률 측정실험을 통해 약 $\pi$/($4.04{\times}10^{-3}$)의 소자 감도(sensitivity)를 최종 확인하였다.

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.

RF magnetron sputtering법으로 제조한 $MoO_3$ 박막의 가스 감지 특성 및 첨가물의 영향 (Gas Sensing Characteristics and Doping Effect of $MoO_3$ Thin Films prepared by RF magnetron sputtering)

  • 황종택;장건익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.460-463
    • /
    • 2002
  • $MoO_3$ thin films were deposited on electrode and heater screen-printed alumina substrates in $O_2$ atmosphere by RF reactive sputtering using Molybdenum metal target. The deposition was performed at $300^{\circ}C$ with 350W of a forward power in an $Ar-O_2$ atmosphere. The working pressure was maintained at $3{\times}10^{-2}mtorr$ and all deposited films were annealed at $500^{\circ}C$ for 5hours. To investigate gas sensing characteristics of the addition doped $MoO_3$ thin film, Co, Ni and Pt were used as adding dopants. The sensing properties were investigated in tenn of gas concentration under exposure of reducing gases such as $H_2$, $NH_3$ and CO at optimum working temperature. Co-doped $MoO_3$ thin film shows the maximum 46.8% of sensitivity in $NH_3$ and Ni-doped $MoO_3$ thin film exhibits 49.7% of sensitivity in $H_2$.

  • PDF

박막형 MoO3가스센서의 가스 감지 특성 및 첨가물의 영향 (Gas Sensing Characteristics and Doping Effect of MoO3Thin Films Sensor)

  • 황종택;장건익;윤대호
    • 한국전기전자재료학회논문지
    • /
    • 제16권8호
    • /
    • pp.705-710
    • /
    • 2003
  • MoO$_3$thin films were deposited on electrode of alumina substrates in $O_2$atmosphere by RF reactive sputtering using molybdenum metal target. The deposition was performed at 30$0^{\circ}C$ with 350 W of a forward power in an Ar-O$_2$atmosphere. The working pressure was maintained at 3$\times$10$^{-2}$ torr and all deposited films were annealed at 50$0^{\circ}C$ for 5 hours. The surface morphology of films was observed by using a SEM and crystalline phases were analyzed by using a XRD. To investigate gas sensing characteristics of the doped MoO$_3$thin film, Co, Ni and Pt were used as dopants. The sensing properties were investigated in term of gas concentration under exposure of reducing gases such as H$_2$, NH$_3$and CO at optimum working temperature. Co-doped MoO3 thin film shows the maximum 46.8 % of sensitivity in NH$_3$ and Ni-doped MoO$_3$thin film exhibits 49.7 % of sensitivity in H$_2$.

발전기 무효전력 출력에 대한 부하모선 전압 민감도 분석 (A sensitivity analysis of bus voltage magnitude to the generator reactive power)

  • 맹종호;박민수;전영환;변성현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.87_88
    • /
    • 2009
  • 계통의 전압 불안정 현상은 다양한 무효전력 공급 설비를 통해 회복될 수 있다. 발전기를 통한 무효전력 공급은 유효전력 출력의 저감으로 이어질 수 있으며, 여기서 기회비용의 발생 가능성이 존재한다. 또한 상정사고가 발생하면 계통의 전압을 안정한 상태로 유지하기 위해 발전기의 적정 무효전력 예비력을 확보하는 것이 필요하다. 하지만 현재 국내에서는 발전사업자가 적정한 무효전력 예비력을 확보하고, 계통의 전압이 떨어지는 경우에 무효전력을 공급하여 안정된 전압을 유지하는 무효전력 보조서비스 제도가 없는 실정이다. 본 연구는 무효전력 보조서비스 제도 도입 준비의 일환으로 발전기의 무효전력 공급에 대한 부하 모선의 민감도를 분석하였다.

  • PDF

대규모 전력계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구 (Subtransmission Reduction for FAGTS Site Selection in Large Power System)

  • 장병훈;추진부;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1302-1304
    • /
    • 1999
  • This Paper Proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive Power has been used to determine the location of shunt type FACTS device, but there is a difficulty to find a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

전압안정도 개선을 고려한 적정 부하차단 기법 (A study on the optimal load shedding scheme considering the voltage stability improvement)

  • 이상중;김건중;김원겸;김용배
    • 대한전기학회논문지
    • /
    • 제44권3호
    • /
    • pp.270-273
    • /
    • 1995
  • This paper proposes an optimal load shedding algorithm by which the system loss can be minimized when the load shedding is unavoidable in case of severe contingency such as the outage of key generators or lines. Shedding load .DELTA.S = .DELTA.P + J.DELTA.Q(MVA) is performed on the weakest bus (on the view of voltage stability), step by step, by the priority of the I.DELTA. = SQRT(.lambda.$\_$P/$\^$2/ + .lambda.$\_$Q/$\^$2/) index given for each load bus, where .lambda.$\_$P/ and .lambda.$\_$Q/ are the sensitivity indices representing the system loss variation versus active and reactive power change of the bus load bus. All loads are assumed to be constant power loads for convenience. A 5 bus sample system proves the effectiveness of the algorithm proposed.