• 제목/요약/키워드: Reactive power compensator

검색결과 171건 처리시간 0.033초

거리를 고려한 Virtual D-STATCOM (Virtual D-STATCOM Considering Distance)

  • 김태훈;오정식;박장현;박태식
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.151-158
    • /
    • 2019
  • 본 논문에서는 태양광 및 풍력 발전소 등에 설치되어 있는 다수의 계통 연계형 인버터를 사용하여 Virtual D-STATCOM을 구성하고, 배전계통의 부하의 무효전력과 배전선로의 거리에 따른 케이블의 무효전력을 보상하여 기존의 단일 대용량 D-STATCOM을 설치하지 않고 변전소 인근의 PCC단의 무효전력을 보상하는 방법을 제시한다. 제안된 방식은 Matlab Simulink 시뮬레이션을 통해 동작원리와 무효전력 보상 성능을 검증하였다.

전력계통의 전압안정도 향상을 위한 변전소의 무효전력 제어 연구 (A Study of Reactive power control for voltage stability enhancement in power system)

  • 이현철;박지호;정태영;정기석;이상덕;유형선;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.191-192
    • /
    • 2011
  • The transmission capacity has been highlighted as a problem in the power company according to operated heavy loaded of transmission facility. The total transfer capability in the KEPCO power system is determined mainly by the voltage stability limit and many approaches for enhancement of the total transfer capability has been consistently performed. This paper proposes a study on determination of the adequate var sizing of power compensator regarding the transfer capability enhancement in power system. This method was controlled power compensator in substation becasue of the voltage stability. It was simulated power system using EMS peak data.

  • PDF

Three-Phase Current Balancing Strategy with Distributed Static Series Compensators

  • Yoon, Hanjong;Yoon, Dongkwan;Choi, Dongmin;Cho, Younghoon
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.803-814
    • /
    • 2019
  • This paper proposes a three-phase current balancing strategy in a power transmission system employing distributed static series compensators (DSSCs). With the proposed variable quadrature voltage injection method, the DSSC emulates either an inductive or a capacitive impedance into the transmission line, and the magnitudes of the phase currents are balanced. Hence, the phase imbalances in the power transmission system are significantly reduced. As a result, the power transfer capability of the transmission lines can be improved. The operational principle of the DSSCs, the hardware structure and the control algorithm are described in detail. Finally, the theoretical analyses and the proposed strategy are experimentally verified through a scaled down transmission system with DSSC prototypes.

DSTATCOM의 순시 유효전력 보상을 이용한 선로의 전류 개선 (Improvement of line Current using Instantaneous Real Power Compensation of DSTATCOM)

  • 정수영;김태현;문승일;권욱현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.327-332
    • /
    • 2002
  • In this paper, conventional reactive power compensation is defined and instantaneous real control concept for shunt converters is proposed. This equipment incorporates the compensation function of harmonics at the distribution line by nonlinear load. These methodologies are applied to IEEE 13 distribution system with the modeling of nonlinear load using EMTEDC/PSCAD package. Simulation with EMTDC results presented to confirm that the new approach has better performance than those obtained by controllers based on traditional concepts of reactive power compensation.

A Magnetic Energy Recovery Switch Based Terminal Voltage Regulator for the Three-Phase Self-Excited Induction Generators in Renewable Energy Systems

  • Wei, Yewen;Kang, Longyun;Huang, Zhizhen;Li, Zhen;Cheng, Miao miao
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1305-1317
    • /
    • 2015
  • Distributed generation systems (DGSs) have been getting more and more attention in terms of renewable energy use and new generation technologies in the past decades. The self-excited induction generator (SEIG) occupies an important role in the area of energy conversion due to its low cost, robustness and simple control. Unlike synchronous generators, the SEIG has to absorb capacitive reactive power from the outer device aiming to stabilize the terminal voltage at load changes. This paper presents a novel static VAR compensator (SVC) called a magnetic energy recovery switch (MERS) to serve as a voltage controller in SEIG powered DGSs. In addition, many small scale SEIGs, instead of a single large one, are applied and devoted to promote the generation efficiency. To begin with, an expandable mathematic model based on a d-q equivalent circuit is created for parallel SEIGs. The control method of the MERS is further improved with the objective of broadening its operating range and restraining current harmonics by parameter optimization. A hybrid control strategy is developed by taking both of the stand-alone and grid-connected modes into consideration. Then simulation and experiments are carried out in the case of single and double SEIG(s) generation. Finally, the measurement results verify that the proposed DGS with SVC-MERS achieves a better stability and higher feasibility. The major advantages of the mentioned variable reactive power supplier, when compared to the STATCOM, include the adoption of a small DC capacitor, line frequency switching, simple control and less loss.

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

KSTAR 전력계통 안정화를 위한 무효전력보상 및 고조파 필터 시스템 설계 (Reactive power compensator and harmonic filter systems design for KSTAR electric power systems stabilization)

  • 홍성록;공종대;황인성;엄대영;김양수;박병주;유항규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.101_102
    • /
    • 2009
  • KSTAR(Korea Superconducting Tokamak Advanced Reseach)장치는 차세대핵융합연구장치로써 30개의 초전도자석으로 구성된다. 이 초전도자석에 전원을 공급하게 되는 PF (Poloidal Field) MPS(Magnet Power Supply)는 12상 Pulse 운전을 하게 되는데 이때 $h=kp{\pm}1$의 특성고조파와 90%에 가까운 무효전력이 발생되어 KSTAR 전력계통과 인근 부하장치에 치명적인 영향을 줄 수 있어 고조파와 무효전력을 동시에 보상할 수 있는 최적의 무효전력보상장치의 도입은 필연적이다. 본 논문에서는 KSTAR 1st Plasma 실험시의 무효전력과 고조파를 저감하기 위해 설치했던 즉, 1단계 기계식 스위칭에 의한 RPC(Reactive power compensator)의 보상특성의 평가결과를 기반으로 KSTAR 2009년 Plasma 실험에 대비하여 이의 운전특성과 설치 공간에 따르는 제약 등을 고려하여 최적의 RPC 설계를 도출하기 위해 실시한 TSC(Thyristor Switch Capacitor)기반의 RPC[1] 모의해석 결과와 기술적 사항을 소개하고자 한다.

  • PDF

DVR을 이용한 전력품질 개선 (Power Quality Improvement using DVR)

  • 김성환
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.462-466
    • /
    • 2021
  • DVR은 배전선로의 전압 변동을 보상하는 장치로 일반적으로 계통의 무효전력 보상, 역률개선 문제를 해결하는 장치와 결합하여 사용된다. 이러한 결합보상기기는 상대적으로 제어가 어렵고 부피가 커지는 단점을 갖는다. 본 논문에서는 DVR의 전력위상제어(Power Angle Contorl)방법을 적용하여 부가적인 보상기기의 결합이 없이 DVR 단독으로 배전선로의 무효전력과 전압변동을 동시에 보상하기 위해 보상 전압의 최대 크기와, 위상, 보상 가능한 무효전력 및 유효전력에 대한 수학적 해석을 수행하였다. 유효전력을 배터리에 충전하고 전압 변동시 저장된 에너지를 공급하기 위한 제어알고리즘을 개발하고 Matlab 시뮬레이션을 통해 결과를 확인하였다.

고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘 (Novel control algorithm for smart PCS with harmonics and reactive power compensation)

  • 서효룡;장성재;박상수;김상용;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF