• Title/Summary/Keyword: Reactive Power Variation

Search Result 122, Processing Time 0.032 seconds

Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory

  • Eskandarian, Nasser;Beromi, Yousef Alinejad;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1303-1313
    • /
    • 2014
  • Dynamic behavior of the harmonic detection part of an active power filter (APF) has an essential role in filter compensation performances during transient conditions. Instantaneous power (p-q) theory is extensively used to design harmonic detectors for active filters. Large overshoot of p-q theory method deteriorates filter response at a large and rapid load change. In this study the harmonic estimation of an APF during transient conditions for balanced three-phase nonlinear loads is conducted. A novel fuzzy instantaneous power (FIP) theory is proposed to improve conventional p-q theory dynamic performances during transient conditions to adapt automatically to any random and rapid nonlinear load change. Adding fuzzy rules in p-q theory improves the decomposition of the alternating current components of active and reactive power signals and develops correct reference during rapid and random current variation. Modifying p-q theory internal high-pass filter performance using fuzzy rules without any drawback is a prospect. In the simulated system using MATLAB/SIMULINK, the shunt active filter is connected to a rapidly time-varying nonlinear load. The harmonic detection parts of the shunt active filter are developed for FIP theory-based and p-q theory-based algorithms. The harmonic detector hardware is also developed using the TMS320F28335 digital signal processor and connected to a laboratory nonlinear load. The software is developed for FIP theory-based and p-q theory-based algorithms. The simulation and experimental tests results verify the ability of the new technique in harmonic detection of rapid changing nonlinear loads.

Static buckling analysis of bi-directional functionally graded sandwich (BFGSW) beams with two different boundary conditions

  • Berkia, Abdelhak;Benguediab, Soumia;Menasria, Abderrahmane;Bouhadra, Abdelhakim;Bourada, Fouad;Mamen, Belgacem;Tounsi, Abdelouahed;Benrahou, Kouider Halim;Benguediab, Mohamed;Hussain, Muzamal
    • Steel and Composite Structures
    • /
    • v.44 no.4
    • /
    • pp.503-517
    • /
    • 2022
  • This paper presents the mechanical buckling of bi-directional functionally graded sandwich beams (BFGSW) with various boundary conditions employing a quasi-3D beam theory, including an integral term in the displacement field, which reduces the number of unknowns and governing equations. The beams are composed of three layers. The core is made from two constituents and varies across the thickness; however, the covering layers of the beams are made of bidirectional functionally graded material (BFGSW) and vary smoothly along the beam length and thickness directions. The power gradation model is considered to estimate the variation of material properties. The used formulation reflects the transverse shear effect and uses only three variables without including the correction factor used in the first shear deformation theory (FSDT) proposed by Timoshenko. The principle of virtual forces is used to obtain stability equations. Moreover, the impacts of the control of the power-law index, layer thickness ratio, length-to-depth ratio, and boundary conditions on buckling response are demonstrated. Our contribution in the present work is applying an analytical solution to investigate the stability behavior of bidirectional FG sandwich beams under various boundary conditions.

Feasibility Analysis of STATCOM Application for Jeiu-Haenam HVDC System (제주-해남 HVDC 시스템에 STASTCOM 적용 타당성 분석)

  • Baek Seung-Taek;Choo Won-Gvo;Han Byung-Moon;Jang Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.401-409
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeju-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Hacnam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

Feasibility Analysis of STATCOM Application for Jeju-Haenam HVDC System (제주-해남 HVDC 시스템에 STATCOM 적용 타당성 분석)

  • Baek, Seung-Taek;Han, Byung-Moon;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.60-62
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeiu-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Haenam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

  • PDF

Diamond-Like Carbon Films Prepared by Magnetized Inductively Coupled Plasma (자화된 유도 결합형 플라즈마를 이용한 다이아몬드성 탄소박막 증착)

  • Kim, Joong-Kyun;Lee, Ho-Jun;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.323-325
    • /
    • 1995
  • An Inductively Coupled Plasma(ICP) was employed to prepare the Diamond-Like Carbon film with $CH_4$ gas. We observed the changes of mechanical, optical properties and internal stress of the films according to the variation of discharge power and negative-self bias. When weak magnetic field is applied, the properties of film are observed to change drastically. In magnetized case, the micro-hardness and the internal stress increase up to critical point and droped down in marked contrast to unmagnetized case. It suggests that large amount of ion flux exists due to high dissociation rate of the reactive radicals in plasma with magnetic field as reported elsewhere. As a result of FT-IR absorption measurement it could be confirmed that the $CH_x$ bonding and the micro-hardness and the internal stress decreased with the increase of negative-self bias.

  • PDF

Speed Sensorless Vector Control System with the Magnetizing Inductance Compensation structure (자화 인덕턴스 보상구조를 가지는 속도센서없는 벡터 제어시스템)

  • Kwon, Young-Gil;Choi, Jung-Soo;Kim, Sang-Uk;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2136-2138
    • /
    • 1998
  • In this study, the speed sensorless vector control system with the magnetizing inductance compensation structure is presented. The estimations of the rotor speed and the magnetizing inductance using the terminal voltages and currents are performed with the reduced order Gopinath flux observer. The rotor speed is estimated by the torque producing current which is derived from the estimated value of the rotor flux and the measured stator currents. In order to compensate the variation of the magnetizing inductance under the saturated conditions, we also established the compensation scheme which is made with the instantaneous reactive power. The validity of the proposed method is verified by simulation results.

  • PDF

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K.O;So J.H;Jung Y.S;Yu G.J;Choi J.Y;Jung S.G;Choy I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1480-1482
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전검출기법의 대표적인 능동적 검출기법인 무효전력변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Neural Network Controller of A Grid-Connected Wind Energy Conversion System for Maximum Power Extraction (계통연계 풍력발전시스템의 최대출력제어를 위한 신경회로망 제어기에 관한 연구)

  • Ro, Kyoung-Soo;Choo, Yeon-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.142-149
    • /
    • 2004
  • This paper presents a neural network controller of a grid-connected wind energy conversion system for extracting maximum power from wind and a power controller to transfer the maximum power extracted into a utility grid. It discusses the modeling and simulation of the wind energy conversion system with the controllers, which consists of an induction generator, a transformer, a link of a rectifier, and an inverter. The paper describes tile drive train model, induction generator model and grid-interface model for dynamics analysis. Maximum power extraction is achieved by controlling the pitch angle of the rotor blades by a neural network controller. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation. The simulation results performed on MATLAB show the variation of the generator torque, the generator rotor speed, the pitch angle, and real/reactive power injected into the grid, etc. Based on the simulation results, the effectiveness of the proposed controllers is verified.

A Study on an Operation Strategy of Dual-Infeed HVDC System

  • Kim, Chan-Ki;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.45-52
    • /
    • 2017
  • This paper deals with the operation strategy of reactive power in a multi-infeed HVDC (MIHVDC) system, in which several converters are connected to the same or nearby separate AC buses. The potential problems concerning a MIHVDC system when feeding a weak AC network are as follows: the need for coordination of the recovery control, the possibility of voltage instability or low quality of the area connected to the MIHVDC system, and the risk of mutual commutation failures. These problems in MIHVDC systems are similar to those in single-infeed HVDC (SIHVDC) systems, but the differences with the phenomenon of the SIHVDC system are the interactions between converters. The main reason for the potential problems of HVDC systems (MIHVDC or SIHVDC) is voltage variation; therefore, to mitigate the voltage variations, the performances of the HVDC system should be enhanced. Consequently, to mitigate the potential problems of MIHVDC systems, several solutions are suggested in this study, including installing STATCOM and installing a line arrester on the tower. The study results will be applied to a multi-infeed HVDC system in Korea.

Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback (정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증)

  • Jo, Jongmin;An, Hyunsung;Park, Jiho;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.141-143
    • /
    • 2018
  • 본 논문은 계통연계형 인버터의 단독운전 방지를 위해 정궤환을 이용한 무효전력 변동기법을 제안하였으며, 구현 및 실험을 통해 단독운전 방지 성능을 검증하였다. PCC 지점에는 양호도($Q_f$) 2.5의 특성을 갖는 3상 RLC 부하가 연결되며, 부하 공진주파수는 60Hz로 설정하였다. 무효전력 변동기법은 일정 크기로 주입되는 무효분과 주파수 편차를 이용한 정궤환으로부터 공급되는 무효분으로 구성된다. 계통연계 운전 시에는 일정한 무효전력 성분만이 공급되며 역률은 0.9975이다. 단독운전 발생 시, 일정 무효전력 때문에 변화된 PCC 주파수와 계통 정격주파수 간의 편차는 정궤환 성분을 활성화하고, 증가된 무효전력에 의한 PCC 주파수 변화를 검출하여 단독운전을 판단한다. 1.7kW 3레벨 T-타입 인버터를 통해 단독운전 방지 성능을 실험하였으며, 검출시간은 각각 53ms, 150ms로써 우수한 성능을 검증하였다.

  • PDF