• Title/Summary/Keyword: Reactive Method

Search Result 1,521, Processing Time 0.028 seconds

Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant (화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구)

  • Lee, Seung-Jae;Jo, Man-Young;Kim, Se-Yong;Kim, Eun-Tae;Kang, Byoung-Wook;Park, Han-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

Immunocytochemical Expression of E-cadherin in Cell Blocks of Serous Effusions (장액성 삼출액의 세포블록에서 E-cadherin의 면역세포화학적 발현)

  • Kim, Byung-Heon;Kwon, O-Jun
    • The Korean Journal of Cytopathology
    • /
    • v.12 no.2
    • /
    • pp.81-87
    • /
    • 2001
  • The differentiation between reactive mesothelial and carcinoma cells in serous effusion cytology can be a diagnostic challenge based on morphology alone. The expression of some cell adhesion molecules may be helpful in the differential diagnosis. This study evaluated the usefulness of E-cadherin Immunocytochemistry for discrimination of carcinoma cells from reactive mesothelial cells. Alcohol fixed, paraffin embedded cell blocks taken from 42 reactive and 102 malignant serous effusions with histologically confirmed diagnoses were immunostained with monoclonal antibody to E-cadherin by LSAB method. E-cadherin expression was identified in only 2 benign reactive serous effusions(5%) whereas 91 malignant serous effusions(89%) expressed E-cadherin The differences in immunostaining for E-cadherin between reactive and malignant serous effusions were statistically significant(p < 0.001). The sensitivity and specificity of the E-cadherin immunostaining for carcinoma cells were 89% and 95%, respectively. In conclusion, E-cadherin is a useful diagnostic adjunct for differentiation between reactive mesothelial and carcinoma cells in serous effusions.

  • PDF

The Affections of System Stability on Replacing the Synchronous Condenser in Jeju Island (제주 동기조상기 교체에 따른 계통안정성 영향 연구)

  • Chang, Byung-Hoon;Yoon, Jong-Su;Han, Jeong-Yeol;Shim, Jeong-Woon;Kang, Sang-Gyun;Lee, Byong-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1715-1720
    • /
    • 2007
  • The CSC-based HVDC system links the Jeju system to the mainland system. Because CSC-based HVDC is installed in Jeju, the reactive power is needed to transfer active power through the HVDC. In order to supply reactive power, switched capacitors and synchronous condensers are installed in Jeju system. The deterioration of established synchronous condensers, however, causes a reactive power supply capability decline and high maintenance cost. It brings about the instability of Jeju system and the incremental of maintenance and repair costs. In the future the installation of wind generators and additional HVDC system would aggravate the stability of Jeju system. Therefore, it needs to consider a countermeasure against above problems. In this paper, Analysis of several contingencies of Jeju system was peformed, and some contingencies caused voltage-reactive power problem was known. CPF method was introduced in order to make countermeasures to replace the synchronous condensers and to solve the voltage-reactive power problem. The location and capacity of reactive power sources were also decided. It could guarantee medium and long term stability of Jeju system.

ENHANCEMENT OF BOBSLEIGH SIMULATION REACTIVE FORCE

  • Ogino, Masatoshi;Taki, Tsuyoshi;Miyazaki, Shinya;Hasegawa, Junichi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.803-807
    • /
    • 2009
  • The bobsleigh is a winter sport which use a sled to slide down an ice-covered course. There is a big expectation for having a training environment and being able to train year round. At present, training is very limited due to the season or course facilities. A variety of VR (Virtual Reality) equipment has been developed in recent years, and it is beginning to spread. We have also made our contribution in bobsleigh simulation. The reactive force applied in our bobsleigh simulation is much smaller than that of a real bobsleigh. This paper proposes a method to enhance reactive force of bobsleigh simulation in real time. The reactive force is magnified instantly in the physically-based simulation. The Laplacian filter is applied to the sequence of reactive force, this technique is often used in the field of image processing. The simulation is comprised of four large scale surround screens and a 6-D.O.F. (Degree Of Freedom) motion system. We also conducted an experiment with several motion patterns to evaluate the effectiveness of enhancement. The experimental results proved useful in some cases.

  • PDF

Novel Coloration of Cotton Fabrics by UV-induced Phtografting of Reactive Black 5 and Acrylic acid

  • Dong, Yuanyuan;Jang, Jin-Ho
    • Textile Coloration and Finishing
    • /
    • v.23 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • UV-induced surface copolymerization has been widely applied as a simple, useful and versatile approach to improve the surface properties of textiles. C.I. Reactive Black 5 and acrylic acid (AA) were continuously grafted onto cotton by UV irradiation. The photografting may occur by the copolymerization of AA with the vinylsulfone reactive dye which photochemically converted from the bissulfatoethylsulfone reactive group. The graft yield and color yield were influenced by UV energy, the dye and photoinitiator concentrations, a mole ratio of AA to dye, and pH. The coloration of cotton fabrics having a K/S of 7.0 can be obtained under a UV irradiation energy of 15$J/cm^2$ by the photografting of an aqueous alkaline formulation of 6% dye concentration containing 3% photoinitiator concentration on the weight of monomers, and a 3:1 mole ratio addition of AA to the dye. Furthermore, the photochemically dyed cotton fabrics showed comparable washing (staining) and rubbing fastness to conventional reactive dyeing method except shade change in the wash fastness and light fastness.

Islanding Detection for a Micro-Grid based on the Instantaneous Active and Reactive Powers in the Time Domain (시간영역에서 순시 유효/무효전력을 이용한 마이크로그리드의 단독운전 판단)

  • Lee, Young-Gui;Kim, Yeon-Hee;Zheng, Tai-Ying;Kim, Tae-Hyun;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.22-27
    • /
    • 2012
  • Correct and fast detection of a micro-grid (MG) islanding is essential to the MG since operation, control and protection of the MG depend on an operating mode i.e., an interconnected mode or an islanding mode. When islanding occurs, the frequency of the point of common coupling (PCC) is not the nominal frequency during the transient state owing to the frequency rise or drop of generators in the MG. Thus, the active and reactive power calculated by the frequency domain based method such as Fourier Transform might contain some errors. This paper proposes an islanding detection algorithm for the MG based on the instantaneous active and reactive powers delivered to the dedicated line in the time domain. During the islanding mode, the instantaneous active and reactive powers delivered to the dedicated line are constants, which depend on the voltage of the PCC and the impedance of the dedicated line. In this paper, the instantaneous active and reactive powers are calculated in the time domain and used to detect islanding. The performance of the proposed algorithm is verified under various scenarios including islanding conditions, fault conditions and load variation using the PSCAD/EMTDC simulator. The results indicate that the algorithm successfully detects islanding for the MG.

Optimal Reactive Power Planning Using Decomposition Method (분할법을 이용한 최적 무효전력 설비계획)

  • 김정부;정동원;김건중;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.585-592
    • /
    • 1989
  • This paper presents an efficient algorithm for the reactive planning of transmission network under normal operating conditions. The optimal operation of a power system is a prerequisite to obtain the optimal investment planning. The operation problem is decomposed into a P-optimization module and a Q-optimization module, but both modules use the same objective function of generation cost. In the investment problem, a new variable decomposition technique is adopted which can operate the operation and the investment variables. The optimization problem is solved by using the gradient projection method (GPM).

  • PDF

A Study on the Analysis and Control of Voltage Stability (전압안정성 분석 및 제어에 관한 연구)

  • 장수형;김규호;유석구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.869-876
    • /
    • 1994
  • This paper presents an efficient method to calculate voltage collapse point and to avoid voltage instability. To evaluate voltage stability in power systems, it is necessary to get critical loading points. For this purpose, this paper uses linear programming to calculate efficiently voltage collapse point. Also, if index value becomes larger than given threshold value, voltage stability is improved by compensation of reactive power at selected bus. This algorithm is verified by simulation on the IEEE 14-bus sample system.

  • PDF

A Load Balancing Control Method in Mobile Ad-Hoc Network (이동 Ad Hoc 네트워크에서 부하분산 제어기법)

  • 송찬호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04a
    • /
    • pp.748-750
    • /
    • 2004
  • AODV나 DSR과 같은 Reactive 라우팅 방식은 트래픽이 발생되는 시점에서 경로를 탐색하는 방법으로서 최적 메시지 전송 경로가 유효하다면 트래픽의 증가와 과도한 에너지 소비를 고려하지 않고 계속적인 동일 전송 경로의 사용으로 인해 특정 노드에 대하여 에너지 소모가 심화될 뿐만 아니라 전송지연이 발생된다. 본 논문에서는 과중한 트래픽 상태를 분산 시켜 전체 네트워크의 균형적인 에너지 소비를 위하여 Reactive 라우팅 방법에서 특정 노드의 트래픽 상태, 에너지 상태, 라우팅 시간을 고려한 노드 상태 기반 부하 분산 방법(NSLB: Node Status-based Load Balancing Method)을 제안한다.

  • PDF

무효전력 최적제어에 의한 전력손실의 최소화

  • Lee, Hyeong-Gwan
    • ETRI Journal
    • /
    • v.6 no.4
    • /
    • pp.31-36
    • /
    • 1984
  • This paper presents an efficient method for real power loss minimization and for improvements in voltage profiles. This method is accomplished by optimal control of reactive power in the system. The problem is formulated as an optimization problem, suitable for solution by linear programming technique. After establishing the objective function for minimizing the system losses with the help of linearised sensitivity relationships of control variables, i. e., the transformer tap position, generator terminal voltages and switchable reactive power sources. The linear programming technique is used to determine the optimal adjustments to the above variables, simultaneously satisfying the constraints. The proposed algorithm has been tested on a sample system and the result is presented and discussed.

  • PDF