• Title/Summary/Keyword: Reactive Method

Search Result 1,521, Processing Time 0.031 seconds

Virtual D-STATCOM Considering Distance (거리를 고려한 Virtual D-STATCOM)

  • Kim, Tae-Hun;Oh, Jeong-Sik;Park, Jang-Hyon;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.151-158
    • /
    • 2019
  • In this paper, we construct a Virtual D-STATCOM using a number of grid-connected inverters installed in solar and wind power plants and compensate the reactive power of the cable depending on the reactive power of the load of the power distribution system and the distance to the power distribution line We propose a method to compensate the reactive power of the PCC stage near the substation without installing the existing single large capacity D-STATCOM. The proposed method is verified by Matlab Simulink simulation and its operation principle and reactive power compensation.

A study for the system voltage and reactive power control (계통전압.무효전력 제어에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.14 no.3
    • /
    • pp.10-17
    • /
    • 1965
  • This paper presents a method of the voltage-reactive power control in the long and short range operations and introduces a conception, "optimum control pattern." The optimum control pattern, aiming at the over-all system control, is defined as the optimum voltage distribution which minimizes the system operating cost under the conditions that the specified power be supplied and the system voltage be kept within the specified bounds. The following procedure was adopted to obtain this optimum pattern. In the first place, a power system was divided into three blocks, namely, load, substation and generator. Lagrange's, multiplier method is applied to each block in turn, paying attention only at the operating voltage distribution. Phase angles at each bus are then modified so that the continuity of active power is maintained. This procedure may be called "block relaxation method with Lagrange's multipliers." In a long range operation, this control pattern determines the optimum installation capacity of reactive power sources. In a short range operation, it also gives the reference state of real time control and the optimum switching capacity of reactive power souces. The real time control problem is also studied from the standpoint of cooperation of control devices such as generators, shunt capacitors, shunt reactors and ratio load controllers. A proposal for the real time control will contribute to the automation of power system operation in the near future. in the near future.

  • PDF

A Novel Anti-Islanding Method for Utility Interconnection of Distributed Power Generation Systems

  • In-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.217-224
    • /
    • 2004
  • A novel anti-islanding method for the distributed power generation system (DPGS) is proposed in this paper. Three different islanding scenarios are explored and presented based on the analysis of real and reactive power mismatch. It is shown via investigation that islanding voltage is a function of real power alone, where its frequency is a function of both real and reactive power. Following this analysis, a robust anti-islanding algorithm is developed. The proposed algorithm continuously perturbs ($\pm$5%) the reactive power supplied by the DPGS while simultaneously monitoring the utility voltage and frequency. In the event of islanding, a measurable frequency deviation takes place, upon which the real power of the DPGS is further reduced to 80%. A drop in voltage positively confirms islanding and the DPGS is then safely disconnected. This method of control is shown to be robust: it is able to detect islanding under resonant loads and is also fast acting (operable in one cycle). Possible islanding conditions are simulated and verified through analysis. Experimental results on a 0.5kW fuel cell system connected to a utility grid are discussed.

A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation (변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구)

  • Jeong, Ki-Seok;Chang, Byun-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

Islanding detection algorithm for microgrid considering reactive power (무효전력을 고려한 마이크로그리드의 단독운전 판단 알고리즘)

  • Kang, Yong-Cheol;Jang, Sung-Il;Cha, Sun-Hee;Lee, Byung-Eun;Kim, Yeon-Hee;Lee, Ji-Hoon;Kim, Yong-Guen
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.236-237
    • /
    • 2006
  • A microgrid is a new type of power system which is formed by the interconnection of small generator to distribution systems. Microgrids are able to supply electric power to their loads independently, which is called with islanding operation, even if they're separated from the power system. As a result, microgrids must be equipped with specific islanding detection schemes for the islanding operation of microgrids. This paper studies an islanding detection method considering reactive power. The proposed method is dealing with the reactive power of the cable which connects between a microgrid and a power system. To show the validity of the proposed method, many islanding operation cases are tested by varying the load conditions of microgrids.

  • PDF

Optimal control for voltage and reactive power using piecewise method (분할수법을 이용한 전압무효전력의 최적제어)

  • 유석구;임화영
    • 전기의세계
    • /
    • v.31 no.5
    • /
    • pp.375-382
    • /
    • 1982
  • The optimum control of voltage and reactive power in large system requires large amounts of complicated calculation. If the large power system is controlled by the centralized control scheme, the necessary computing time, memory requirments and data transmission channels increase exponetially, and computer control of the system becomes difficult. Piecewise method which aims at the reduction of the difficulties of centralized control scheme is to decompose a large power system into several subsystems, each of which is controlled by a local computer and the control efforts of each subsystem are coordinated by a central computer. Unless sufficient coordination is made between subsystems, the control quality may become very poor. This paper describes how piecewise method can be applied in the optimal control of voltage and reactive power in large system, and presents effective calaulating algorithm for the solution of the problem. The numerical example for model system is presented here.

  • PDF

Linear Programming based Optimal Reactive Power Dispatch using Modified Sensitivity Method (수정된 민감도 기법을 이용한 선형계획법 기반의 무효전력 최적배분)

  • Kim, Tae-Kwon;Kim, Byung-Seop;Kim, Min-Soo;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.190-193
    • /
    • 2001
  • This paper presents a linear programming based Optimal Reactive Power Dispatch (ORPD) problem using modified sensitivity method. The proposed model minimizes the real power losses and improves the voltage profiles in the system with consideration of voltage and reactive power constraints. The method employs modified sensitivity relationships of power systems to establish both the objective function for minimizing the system losses and the system performance sensitivities relating dependent and control variables. The proposed algorithm has been evaluated with the IEEE 6-bus and IEEE 30-bus systems.

  • PDF

Current Measurement based Reactive Power Control to Mitigate Overvoltage of Primary Distribution Line (배전선로 규정전압 유지를 위한 전류 측정치 기준의 무효전력 제어방법)

  • Hwang, Jihui;Lim, Seongil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1547-1553
    • /
    • 2017
  • Due to the high penetration ratio of dispersed generations, overvoltage problem of the feeder has become more an important issue in distribution system operation. This paper proposes a new method for the smart inverter to control reactive power to mitigate voltage rise by the reverse power flow from the DGs. The proposed method controls reactive power based on current measurement while conventional methods use voltage measurement which include unacceptably large errors. Various case studies using MATLAB simulation have been performed to verify effectiveness of proposed method.

Advanced LCD modes through surface modification using reactive mesogen mixed with alignment layers

  • Lee, You-Jin;Kim, Young-Ki;Jo, Soo-In;Yu, Chang-Jae;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.91-94
    • /
    • 2009
  • We propose advanced liquid crystal display (LCD) modes through surface modification using UV curable reactive mesogen (RM) mixed with alignment layers. The LC directors on the modified alignment layer are controlled and memorized by the polymerized RMs under an applied voltage. Using the method proposed here, we can improve the response time and viewing angle characteristics through surface controlled patterned vertical alignment (SC-PVA) mode and 8-domains PVA mode, respectively. Also, we found that the method can be applicable to fabricate multi-domain structures using multiple UV exposure as same as conventional UV alignment method.

  • PDF

Control Strategy for Accurate Reactive Power Sharing in Islanded Microgrids

  • Pham, Xuan Hoa Thi;Le, Toi Thanh
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1020-1033
    • /
    • 2019
  • This paper presents a control strategy to enhance the accuracy of reactive power sharing between paralleled three-phase inverters in an islanded microgrid. In this study, the mismatch of power sharing when the line impedances have significant differences between inverters connected to a microgrid has been solved, the accuracy of the reactive power sharing in an islanded microgrid is increased, the voltage droop slope is tuned to compensate for the mismatch of voltage drops across the line impedances by using an enhanced droop controller. The proposed method ensures accurate power sharing even if the microgrid has local loads at the output of the inverters. The control model has been simulated by MATLAB/Simulink with two or three inverters connected in parallel. Simulation results demonstrate the accuracy of the implemented control method. Furthermore, in order to validate the theoretical analysis and simulation results, an experimental setup was built in the laboratory. Results obtained from the experimental setup verify the effectiveness of the proposed method.