• 제목/요약/키워드: Reactive Compensation

검색결과 320건 처리시간 0.025초

Active/Reactive Compound Compensation in Distribution System

  • Sul, Yong-Tae
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.46-52
    • /
    • 1997
  • In this paper th use of compensation based on a combination of active plus reactive power at distribution model system is proposed. The basic voltage-power relationships for the linearized case on an infinite bus are used and the compensation angle is defined based on the voltage magnitude response to small power injection. Compensation is supplied at several locations, and the system is subjected to varying fault scenarios, with its response observed under different system conditions. As number of control issues for a storage-based active/reactive power compensator as a bus voltage regulator are explored to compare the effectiveness of active/reactive again reactive-only compensation.

  • PDF

Thyristor Switch를 사용한 무효전류 보상에 관한 연구 (A Study on Reactive Current Compensation Using Thyristor Switch)

  • 박민호;이복용
    • 전기의세계
    • /
    • 제28권12호
    • /
    • pp.41-45
    • /
    • 1979
  • Improvement of power factor is achieved by reactive-current compensation, connecting power condenser to the circuit. This paper describes a method of reactive-current compensation, employing thyristor switching of capacitor banks without any breaker. This method reduces supply transients to the minimum by means of connecting condenser, because thyristor is triggered at zero point in condenser current. The reactive current detection and the experimental system to trigger thyristor at appropriate moment are given. IThe results show the fast reactive-current compensation on the condition of minimum transient.

  • PDF

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

저단락비 HVDC 시스템에서웨 무효편력수급 최적 방안 연구 (Study on Optimized Scheme of Reactive Power Compensation for Low Short-Circuit-Ratio HVDC System)

  • 백승택;한병문;오세승;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.434-440
    • /
    • 2005
  • This paper describes an optimized Scheme of reactive-power compensation for the low short-circuit-ratio AC system interconnected with the HVDC system. An HVDC system interconnected with tile low SCR AC system is vulnerable to the ac voltage variation, which brings about the commutation failure of the converter. This problem can be solved using optimized compensation of reactive power. In this study, a benchmark system for HVDC system interconnected with low SCR AC system is derived using PSS/E simulation. Then an optimized srheme for reactive power compensation was derived using integer programming. The feasibility of proposed scheme was analyzed through silnulations with PSS/E and PSCAD/EMTDC. The proposed scheme can compensate the reactive power accurately and minimize the number of switching for harmonic filters and shunt reactors.

PWM 콘버어터를 이용한 순시무효전력 보상장치의 동작해석 (A Study on the Operation Characteristics of a Reactive Power Copensator using PWM Converter)

  • 권기현;권순재;김철우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.310-312
    • /
    • 1989
  • From the viewpoint of an effective energy use, many method for reactive power compensation has been developed. Among of the reactive power compensation, this paper describes the relation of operation interpretation, filter, hysteresis width and switching time of current controlled PWM converter which has excellent reactive power compensation. This current controlled PWM convertor is excellent the view of reactive power compensation by current control method using hysteresis comparator method, but is required element of high response characteristics. Therefore this paper offers the series of data for system considering switching characteristics of switching element.

  • PDF

능동 데이터베이스 기반 무효전력 보상장치 감시제어 시스템 (A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.189-194
    • /
    • 2012
  • 수배전 무효전력 보상 감시 제어시스템은 수배전단에 설치된 유도 모터, 또는 아크 용접기 등과 같은 유도성 부하에서 발생되는 지상무효전력을 보상하고 역률의 개선, 전압 강하의 경감, 전력손실을 감소 시켜줌으로써 전력설비 계통을 경제적이고 안정적으로 운영하도록 도와준다. 그리고 이러한 시스템은 중앙전력감시반이 획득한 수변전설비의 운전상태 및 계측 Data를 근거로 역률 및 위상각을 분석하여 기준 위상각이상으로 전압과 전류의 위상차가 발생 되었을 경우, 무효전력 보상장치의 ON/OFF제어를 수행하여 효율적인 계통관리가 가능하도록 한다. 본 연구에서는 능동데이터베이스를 이용하여 무효전력 보상장치 감시제어 시스템을 구현하는 방안을 제시함으로써, 공장 부하의 지상무효전력이 급격한 증가로 인한 역률 저하, 전압 강하, 손실 발생 등의 징후 발생 시 이에 대한 대처를 사용자(operator)의 개입 없이 데이터베이스 스스로 수행하도록 함으로써 인위에 의한 실수를 최소화 하도록 하였다.

배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상 (Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer)

  • 김형수;최종우
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

전력품질 향상을 위한 배전용 STATCOM 운전결과 분석 (Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality)

  • 오관일;전영수;박상태;추진부
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.377-385
    • /
    • 2000
  • 본 논문에서는 국내 최초로 설치된 Custom Power기기인 배전용 STATCOM(STATic COMpensator)의 기기 신뢰성 확보를 위힌 기가 테스트 및 설계통 운전 분석결과를 보이고 있다. Custom Power는 유연송전시스템(FACTS : Flexible AC Transmission System)과 같이 교류전력계통을 제어함으로써 효율적이고 유연한 전력계통의 운용과 구성을 목적으로 한다. STATCOM은 Custom Power기기의 한 형태로 무효전력 보상, 전압조정, 그리고 전압 퓰리커 억제 등의 기능을 가진다. 본 논문에서는 STATCOM 시운전 결과 무효전력과 역률 보상에서 우수한 성능을 보임을 확인할 수 있다.

  • PDF

선형계획법을 이용한 무효전력 설비 계획 (Reactive Power Planning Using Linear Programming)

  • 김정부;박영문
    • 대한전기학회논문지
    • /
    • 제38권10호
    • /
    • pp.805-810
    • /
    • 1989
  • This paper presents a method for planning reactive power compensation such as shunt capacitors and reacters so as to maintain bus voltage in acceptable range during steady state operation in power system. The algorithm in this paper decomposes the problem into reactive power planning module for the compensation of bus voltage and load flow module for adjusting the error resulted from the linear approximation. A planning technique is based on linear programming to minimize the amount of added reactive power compensation in each case. Transformer tap settings and generator voltages are adjusted to minimize the compensation. The constraints are the operation limits of the control variables and bus voltages. The result of one sample system is presented to confirm the practical use of the proposed algorithm.

  • PDF