• 제목/요약/키워드: Reactivation

검색결과 231건 처리시간 0.04초

활성탄 재생이 자연유기물질의 흡착에 미치는 영향 (Effect of Reactivation of Activated Carbon on Adsorption of Natural Organic Matter)

  • 홍성호;최주솔
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.323-329
    • /
    • 2007
  • There is no certain definition about advanced drinking water treatment but it is generally known as activated carbon process, membrane process or ozone process which can remove non-conventional pollutants such as taste and odor compounds, and micro-pollutants. There are more than 20 processes related to activated carbon as adsorber or biological activated carbon in Korea. The saturated carbon by pollutants can be reused by reactivation. However, the effect of reactivation on activated carbon is not well-understood in terms of changing physical properties of carbon to adsorption capacity of natural organic matter (NOM). In this study, the effects of reactivation on physical properties of activated carbon were investigated by isotherm and breakthrough of NOM. Ash content was increased from 8% to 13.3%. Iodine number is commonly used as an indicator for performance of reactivation. The iodine number was decreased about 20% after reactivating twice. The degree of reactivation can be evaluated by not only iodine number but also apparent density.

콩나물 Peroxidase의 열안정성과 재활성화 (Thermostability and Reactivation of Peroxidase from Soybean Sprouts)

  • 박인식;이민경;길지은
    • 한국식품영양과학회지
    • /
    • 제28권1호
    • /
    • pp.81-86
    • /
    • 1999
  • The factors affecting thermostability and reactivation of peroxidase from soybean sprouts(Glycine max L.) were investigated. The enzyme was the most stable at pH 7.0 and below 60oC. Thermostability of the enzyme was reduced by addition of sodium chloride and saccharides. The partially inactivated enzyme by heat treatment at 75oC for 10 min was reactivated up to 211.5% at the optimal reactivation condition. The optimal pH and temperature for reactivation of the enzyme were pH 9.0 and 40oC, respectively. The reactivation was completely inhibited by addition of sulfhydryl reagent such as L cysteine.

  • PDF

한국산 무 Peroxidase의 열변성 및 재활성화에 미치는 요인 (Factors Affecting Thermal Inactivation and Reactivation of Korean-Radish Peroxidase)

  • 이경아;홍정민;김기남;박인식
    • 한국식품영양과학회지
    • /
    • 제19권4호
    • /
    • pp.301-304
    • /
    • 1990
  • Factors affecting thermal inactivation and reactivation of korean radish peroxidase were inves-tigated,. The enzyme was stable below pH4.0 and above pH 8.0 The thermostablity of the enzyme was increased by addition of glucose sodium chloride and albuminl The inactivated enzyme by heat treatment was reactivated at room temperaturem The optimal pH for reactivation of the enzyme was pH of 9.0 The reactivation rate of the enyme was not afected by addition of glucose sodium chloride and albumin, The reactivation was completely inhibited by addition of sulfhydryl reagent such as dithiothreitol.

  • PDF

호주 Gippsland Basin에서 $CO_2$ 주입 중 단층 재활성화의 가능성 (Fault reactivation potential during $CO_2$ injection in the Gippsland Basin, Australia)

  • Ruth, Peter J. van;Nelson, Emma J.;Hillis, Richard R.
    • 지구물리와물리탐사
    • /
    • 제9권1호
    • /
    • pp.50-59
    • /
    • 2006
  • 현재의 응력장내에서 단층 재활성화를 야기하는데 필요한 공극압의 증가를 추정함으로써 재활성화 위험도를 결정하는 FAST(단층 분석 확인 기술)를 이용해 Gippsland Basin의 단층 재환성의 위험도가 계산되었다. Gippsland Basin의 응력 형태는 주향이동단층과 역단층의 경계부근으로서 즉, 최대 수평 압력$({\sim}40.5\;MPa/km)$ > 수직 압력(21 MPa/km) ${\sim}$ 최소 수평 압력(200 MPa/km)이다. 공극압은 Golden Beach Subgroup의 Campanian volcanics 상부에서 정수압이다. 여기에서 결정된 NW-SE 최대 수평 응력 방향$(139^{\circ}N)$은 이전의 측정값들과 대체로 일치하고 Gippsland Basin에서의 NW-SE 최대 수평 응력 방향을 입증한다. Gippsland Basin의 단층 재활성화 위험도는, cohesionless fault$(C=0;\;{\mu}=0.65)$와 healed fault$(C=5.4;\;{\mu}=0.78)$, 두 가지 단층 강도 시나리오를 이용해서 계산되었다. 상대적으로 높고 낮은 재활성화 가능성을 가진 단층들의 방향은 cohesionless fault 와 healed fault 모두에 대해 거의 동일하다. NE-SW 주향방향의 큰 각을 가진 단층들은 현재의 응력상태하에서는 재활성화 가능성이 거의 없다. SSE-NNW 과 ENE-WSW 방향의 큰 각을 가진 단층들이 단층 재활성화 위험도가 가장 높다. 부가적으로 NE-SW 주향 방향의 작은 각을 가진 단층(thrust 단층)은 상대적으로 높은 재활성화 위험도를 가지고 있다. 최적 방향 단층들에 대한 가장 높은 재활성화 위험도는 cohesionless fault에 대해서는 추정 공극압의 3.8MPa$({\sim}548psi)$ 증가(Delta P), healed fault에 대해서는 15.6MPa 증가에 해당된다. 이 논문에서 제시된 단층 재활성화 분석으로부터 얻은 공극압 증가의 절대값은 지구역학적인 모델(원위치 응력과 암석 강도 자료)에서의 불확실성으로 인해 큰 오차를 수반한다. 특히, 최대 수평 응력 강도와 단층 강도 자료는 좁은 범위에 한정되어 있지 않다. 그러므로 단풍 재활성화 분석은 저류층 내에서 최대로 허용할 수 있는 공극압 증가를 직접 측정하는데 사용될 수 없다. 이러한 종류의 단층 재활성화 분석은 단지 단층 재활성화의 상대적인 위험도의 평가에 사용될 수 있을 뿐이고, 재활성화에 앞서 단층이 견딜 수 있는 공극압 증가의 최대 허용치를 결정하는데는 사용할 수 없다고 주장하고자 한다.

결핵성 흉막염에서 초감염 결핵과 재발성 결핵의 임상 양상 (Tuberculous Pleurisy : Clinical Characteristics of Primary and Reactivation Disease)

  • 홍구현;임상수;신재민;박재석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제61권6호
    • /
    • pp.526-532
    • /
    • 2006
  • 연구배경: 결핵성 흉막염은 대부분 초감염 결핵의 형태로 발생하는 것으로 알려져 왔다. 그러나 최근 결핵환자가 감소함에 따라 초감염 결핵보다 재발성 결핵으로 결핵성 흉막염이 발생하는 경향이 늘고 있다. 대상 및 방법: 2003년 1월부터 2006년 2월까지 단국대학교병원에서 결핵성 흉막염으로 진단받은 환자들의 과거력과 방사선 소견에 따라 초감염 결핵과 재발성 결핵으로 분류하고 두 군 사이에 임상 소견, 방사선 소견, 그리고 6 개월 동안 항결핵 약물치료 후 잔여 흉막비후에 있어서 차이가 있는지 알아보았다. 결 과: 1. 결핵성 흉막염 환자 141명 중에서 135명에서 초감염 결핵과 재발성 결핵의 구분이 가능하였는데 초감염 결핵의 소견을 보인 환자는 38명(28%), 재발성 결핵의 소견을 보인 환자는 97명(72%)으로 재발성 결핵의 소견을 보이는 환자가 더 많았다. 2. 초감염과 재발성 결핵 환자 사이에서 성별, 나이, 증상의 발현 시작부터 흉수검사까지의 기간, 진단 시의 흉수의 양, 흉수 총백혈구수, 림프구수, LDH, ADA 수치에 있어서 유의한 차이가 없었다. 3. 6개월 이상 추적관찰이 가능하였던 124명의 환자들의 잔여 흉막비후의 정도에 있어서 초감염 결핵과 재발성 결핵 사이에 차이가 없었다. 결 론: 결핵성 흉막염 환자 중에서 초감염 결핵보다 재발성 결핵의 소견을 보이는 환자가 더 많았으며 두 군 사이에 임상 소견, 방사선 소견, 흉수 소견에서 유의한 차이가 없었으며, 6 개월 치료 후의 잔여 흉막비후의 정도에 있어서도 유의한 차이가 없었다.

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

전기화학적 재활성화 분극시험에 의한 터빈부재의 열화손상 평가 (Degradation Damage Evaluation for Turbine Structural Components by Electrochemical Reactivation Polarization Test)

  • 권일현;백승세;류대영;유효선
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1241-1249
    • /
    • 2002
  • The extent of materials deterioration can be evaluated accurately by mechanical test such as impact test or creep test. But it is almost impossible to extract a large test specimen from in-service components. Thus material degradation evaluation by non-destructive method is earnestly required. In this paper, the material degradation for virgin and several aged materials of a Cr-Mo-V steel, which is an candidated as structural material of the turbine casing components for electric power plant, is nondestructively evaluated by reactivation polarization testing method. And, the results obtained from the test are compared with those in small punch(SP) tests recommended as a semi-nondestructive testing method using miniaturized specimen. In contrast to the aged materials up to 1,000hrs which exhibit the degradation behaviors with increased ${\Delta}[DBTT]_{SP}$, the improvement of mechanical property can be observed on the 2,000hrs and 3,000hrs aged materials. This is because of the softening of material due to the carbide precipitation, the increase of ferritic structures and the recovery of dislocation microstructure by long-time heat treatment. The reactivation rates($I_R/I_{Crit},\;Q_R/Q_{Crit}$) calculated by reactivation current densityt ($I_R$) and charge($Q_R$) in the polarization curves exhibit a good correlation with ${\Delta}[DBTT]_{SP}$ behaviors.

재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가 (An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test)

  • 권일현;나성훈;송기욱;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

A Restrictive Virus Tropism, Latency and Reactivation of Pseudorabies Virus Following Irreversible Deletion of Bsrl Restriction Site in the Thymidine-kinase Gene

  • Mohd Lila Mohd Azmi;Zeenathul, Nazariah-Allaudin;Abdel-Wahid Saeed Ali;Che Abdul Rahim Mohamed;Kamarudin, Awag-Isa
    • Journal of Microbiology
    • /
    • 제40권1호
    • /
    • pp.1-10
    • /
    • 2002
  • At the dose of 1000 p.f.u. per mouse,100% mortality occurred in mice inoculated with wild-type pseudorabies virus (PrV). In contrast, upon stable deletion of 10 bp nucleotides at the Bsrl site within the TK gene, PrV was rendered to be completely apathogenic. The deletion also caused the virus to be less capable of replicating in respiratory as well as in nervous system tissues. Although animals were exposed to high titers of TK-deleted PrVs, the virus failed to replicate to a high titer as compared to the pathogenic parental virus. In contrast to previous studies the deletion in the TK gene did not prevent the virus from establishing latency. Upon immunosuppression, the latent virus? however, reactivated but replicated at low titers. Interestingly, TK-deleted virus established latency and reactivation, that are occurred only in trigeminal ganglia and the cerebrums and no other tissues involved. Following reactivation, there was no indication of virus shedding in respiratory tissues as confirmed by virus isolation and polymerase chain reaction (PCR) technique targeting at the gB gene of PrV, The non-pathogenic virus with non-shedding characteristics, upon reactivation of the latent virus, would be the important feature of a live virus vaccine candidate.

Fault Reactivation에 의한 가상 방사성폐기물 처분장 주변 지하수 유동 변화 평가 : 2차원 케이스 스터디 (A Case Study on the Effect of Fault Reactivation on Groundwater Flow around a Hypothetical HLW Repository)

  • 서은진;황용수;한지웅
    • 터널과지하공간
    • /
    • 제16권4호
    • /
    • pp.307-312
    • /
    • 2006
  • 처분 용기 부식 후 유출된 방사성 핵종은 지하수 유동 경로를 따라 이동하게 된다. 따라서 지하 암반내 지하수 유동 평가는 처분 안전성 평가를 위한 기본적인 요소라 할 수 있다. 본 연구에서는 처분 시스템 폐쇄 후 미래 특정 시점에서 지형의 변화가 지하수 유동 경로에 끼치는 영향을 다공질 매질에서의 지하수 유동 해석 코드인 NAMMU를 이용한 평가를 통해 확인해 보았다. 단열에 인접한 지역에 가상의 처분 시스템을 선정하고 처분 시스템 주위에 존재하는 단열의 재활성화가 발생하는 경우 처분장으로부터의 지하수 유동에 끼치는 영향을 정량적으로 평가해 보았다.