• Title/Summary/Keyword: Reaction Cross Section

Search Result 116, Processing Time 0.028 seconds

Study on the Output Current for Electrochemical Low-energy Neutrino Detector with Regards to Oxygen Concentration

  • Suda, Shoya;Ishibashi, Kenji;Riyana, Eka Sapta;Aida, Yani Nur;Nakamura, Shohei;Imahayashi, Yoichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • Background: Experiments with small electrochemical apparatus were previously carried out for detecting low-energy neutrinos under irradiation of reactor neutrinos and under natural neutrino environment. The experimental result indicated that the output current of reactor-neutrino irradiated detector was appreciably larger than that of natural environmental one. Usual interaction cross-sections of neutrinos are quite small, so that they do not explain the experimental result at all. Materials and Methods: To understand the experimental data, we propose that some biological products may generate AV-type scalar field B0, leading to a large interaction cross-section. The output current generation is ascribed to an electrochemical process that may be assisted by weak interaction phenomena. Dissolved oxygen concentrations in the detector solution were measured in this study, for the purpose of understanding the mechanism of the detector output current generation. Results and Discussion: It was found that the time evolution of experimental output current was mostly reproduced in simulation calculation on the basis of the measured dissolved oxygen concentration. Conclusion: We mostly explained the variation of experimental data by using the electrochemical half-cell analysis model based on the DO concentration that is consistent to the experiment.

Study on (n, α) reactions for the production of 51Cr, 89Sr, 99Tc, 131I, 133Xe, 137Cs and 153Sm radioisotopes used in nuclear medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3352-3358
    • /
    • 2023
  • Nuclear medicine seems to be a decent choice of medicine in the recent decade. The radioactive isotopes 51Cr, 89Sr, 99Tc, 131I, 133Xe, 137Cs and 153Sm are extremely essential in nuclear medicine. The excitation functions of the 54Fe (n, α) 51Cr, 92Zr (n, α) 89Sr, 102Rh (n, α) 99Tc, 134Cs (n, α) 131I, 136Ba (n, α) 133Xe, 140La (n, α) 137Cs and 156Gd (n, α) 153Sm reactions were calculated in this study using the EMPIRE 3.2.3 and TALYS 1.95 nuclear codes. Additionally, the cross sections at 14-15 MeV were calculated using empirical formulae and the experimental data. The computer codes were compared to the experimental data and Empirical formulas as well as the evaluated data (TENDL 2021, JENDL 3.3, JENDL 5, JEFF 3.3, EAF 2010, CENDL 3.1, CENDL 3.2, ROSFOND 2010, FENDL 3.2 b, and BROND 3.1).

Study on (n,p) reactions of 58Ni, 99Tc, 99Ru, 131Xe, 133Cs and 186Os radioisotopes used in medicine

  • Hallo M. Abdullah;Ali H. Ahmed
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.304-309
    • /
    • 2023
  • In the last decade, nuclear medicine appears to be a good choice of medicine. 58Co, 99Mo, 99Tc, 99Re, 133Xe and 186Re are very important radionuclides for nuclear medicine. In this study, the excitation functions of 58Ni (n, p) 58Co, 99Tc (n, p) 99Mo, 99Ru (n, p) 99Tc, 131Xe (n, p) 131I, 133Cs (n, p) 133Xe and 186Os (n, p) 186Re nuclear reactions were calculated at neutron energies between 1 and 20 MeV using TALYS 1.95 and EMPIRE 3.2 nuclear codes. Furthermore, the cross sections were calculated with the empirical formula derived in our past study at 14-15 MeV. The obtained results were compared with the measured values in EXFOR library, and with the evaluated data of (JENDL-4.0/HE, JEFF-3.3, TENDL-2019, ENDF/B-VIII.0, IRDFF-II, JENDL/ImPACT-18). The results are in good agreement with those of the evaluated data libraries and experimental results and indicates that these radioisotopes can be produced by smaller cyclotrons.

The Effects of the Amount of $\textrm{SiO}_2$ Dopant on the Melt Oxidation Behavior of the Al-Alloy (Al-합금의 용융산화거동에 미치는 $\textrm{SiO}_2$도판트 량의 영향)

  • Gang, Jeong-Yun;Kim, Il-Su
    • Korean Journal of Materials Research
    • /
    • v.9 no.6
    • /
    • pp.609-614
    • /
    • 1999
  • The effect of the amount of $SiO_2$dopant on the behavior of $AlO_2$$O_3$-composite formation by melt oxdation of Al-alloy was examined in this paper. The $SiO_2$powder was spread on the top surface of the Al-1Mg-3-Si-5Zn-1Cu alloy in th alumina crucible. The selected amount of each powder was 0.03, 0.10, 0.16g/$\textrm{cm}^2$. The oxidation behavior was determined by observing the weight gain after the heat treatment for 10 hours at 1373K. The macroscopic structure of formed oxide layer was examined by an optical microscope. The top surface and the cross-section of the grown oxide layer were investigated by SEM and analysed by EDX. The $SiO_2$ powder was determined to enhance oxidation by thermit reaction with Al which reduced the growth incubation period of the oxidation layer. As the amount of the $SiO_2$dopant increased, the growth rate decreased due to the precipitated Si which blocked the Al-alloy channel in the composite materials. However, more uniform layer was obtained due to the occurrance of the enhanced oxidation reaction in the whole alloy surface compared to the case of addition of less amount of dopant.

  • PDF

Verification of OpenMC for fast reactor physics analysis with China experimental fast reactor start-up tests

  • Guo, Hui;Huo, Xingkai;Feng, Kuaiyuan;Gu, Hanyang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3897-3908
    • /
    • 2022
  • High-fidelity nuclear data libraries and neutronics simulation tools are essential for the development of fast reactors. The IAEA coordinated research project on "Neutronics Benchmark of CEFR Start-Up Tests" offers valuable data for the qualification of nuclear data libraries and neutronics codes. This paper focuses on the verification and validation of the CEFR start-up modelling using OpenMC Monte-Carlo code against the experimental measurements. The OpenMC simulation results agree well with the measurements in criticality, control rod worth, sodium void reactivity, temperature reactivity, subassembly swap reactivity, and reaction distribution. In feedback coefficient evaluations, an additional state method shows high consistency with lower uncertainty. Among 122 relative errors in the benchmark of the distribution of nuclear reaction, 104 errors are less than 10% and 84 errors are less than 5%. The results demonstrate the high reliability of OpenMC for its application in fast reactor simulations. In the companion paper, the influence of cross-section libraries is investigated using neutronics modelling in this paper.

Analysis of Biomechanical Characteristics of Therapist's Ground Reaction and Contact Hand Force and Time According to Table Height During Spinal Manipulation

  • Jejeong Lee;Yongwoo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.2
    • /
    • pp.130-139
    • /
    • 2023
  • Objective: This study aimed to analyze the effects and characteristics of the height of the treatment table on the force and time of ground reaction (GR) and contact hand (CH) generated from the therapist's feet to generate thrust during spinal manipulation (SM). Design: A cross-sectional survey study Methods: Thirty-six healthy subjects were recruited. SM was performed on the ilium using a knee-high table, where the therapist felt it was easy to control the subject's posture and body shape and comfortable to generate force, as well as a relatively high thigh-high table. The force and time generated by the therapist's GR and CH were simultaneously measured through a force plate. Results: As a result, there was a significant difference in peak force and rundown force at the therapist's GR according to the table height (p < 0.05). In the therapist's CH, there was a significant difference between PreMin (preload minimum) force and peak force (p < 0.05), and there was a significant difference between the time from PreMin to peak and the time of the entire section (p < 0.05). Conclusions: As a result, the generation of increased CH force and faster thrust duration were confirmed by mobilizing the reduced GR force of the therapist to generate thrust than the relatively high table on the knee-high table.

Glucose Oxidase-Coated ZnO Nanowires for Glucose Sensor Applications

  • Noh, Kyung-Min;Sung, Yun-Mo
    • Korean Journal of Materials Research
    • /
    • v.18 no.12
    • /
    • pp.669-672
    • /
    • 2008
  • Well-aligned Zinc oxide (ZnO) nanowires were synthesized on silicon substrates by a carbothermal evaporation method using a mixture of ZnO and graphite powder with Au thin film was used as a catalyst. The XRD results showed that as-prepared product is the hexagonal wurzite ZnO nanostructure and SEM images demonstrated that ZnO nanowires had been grown along the [0001] direction with hexagonal cross section. As-grown ZnO nanowires were coated with glucose oxidase (GOx) for glucose sensing. Glucose converted into gluconic acid by reaction with GOx and two electrons are generated. They transfer into ZnO nanowires due to the electric force between electrons and the positively charged ZnO nanostructures in PBS. Photoluminescence (PL) spectroscopy was employed for investigating the movements of electrons, and the peak PL intensity increased with the glucose concentration and became saturated when the glucose concentration is above 10 mM. These results demonstrate that ZnO nanostructures have potential applications in biosensors.

Self-Assembling Adhesive Bonding by Using Fusible Alloy Paste for Microelectronics Packaging

  • Yasuda, Kiyokazu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • In the modern packaging technologies highly condensed metal interconnects are typically formed by highcost processes. These methods inevitably require the precise controls of mutually dependant process parameters, which usually cause the difficulty of the change in the layout design for interconnects of chip to-chip, or chip-to-substrate. In order to overcome these problems, the unique concept and methodology of self-assembly even in micro-meter scale were developed. In this report we focus on the factors which influenced the self-formed bumps by analyzing the phenomenon experimentally. In case of RMA flux, homogenous pattern was obtained in both plain surface and cross-section surface observation. By using RA flux, the phenomena were accelerated although the self-formtion results was inhomogenous. With ussage of moderate RA flux, reaction rate of the self-formation was accelerated with homogeneous pattern.

Advantage and Disadvantage of Autoradiography - Current topics of Autoradiography in New Drug Devlopment Studies of Japan

  • Shigematsu, Akiyo;Motoji, Naomi;Mori, Keiji;Aihara, Michiaki
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.229-230
    • /
    • 1996
  • The 116 annual meeting of the Pharmaceutical Society of Japan was held in Kanazawa from March 27 to 29 in 1996, Our presentation will be concerned to a few topics in this meeting. Recently not only pharmaco- and toxico-kinetic studies but also pharmaco- and toxico-dynamic studies are beginning to be worthy of notice. This is quite reasonable, because the blood concentration-time curves of a parent compound must be useful, but it is no more than a cross section for pharmaco- and toxico-dynamic in many organs and tissues as main reaction site for drug metabolism,

  • PDF

Advantage and Disadvantage of Autoradiography - Current topics of Autoradiography in New Drug Development Studies of Japan

  • Shigematsu, Akiyo;Motoji, Naomi;Mori, Keiji;Aihara, Michiaki
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.262-263
    • /
    • 1996
  • The 116 annual meeting of the pharmaceutical Society of Japan was held in Kanazawa from March 27 to 29 in 1996. Our presentation will be concerned to a few topics in this meeting. Recently not only pharmaco and toxico kinetic studies but also pharmaco and toxico dynamic studies are beginning to be worthy of notice. This is quite reasonable. because the blood concentration time curves of a parent compound must be useful, but it is no more than a cross section for pharmaco and toxico dynamics in many organs and tissues as main reaction site for drug metabolism.

  • PDF