• Title/Summary/Keyword: Reaction Accuracy

Search Result 396, Processing Time 0.022 seconds

Relation of Sampling Time to the Detection of Enteroviral RNA in Cerebrospinal Fluid from the Patients with Aseptic Meningitis (무균성 수막염 환자의 뇌척수액 채취 시기와 장바이러스 RNA 검출과의 관계)

  • Lee, Kyu Man;Park, Soon Young;Kang, Hee Jung;Lee, Eun Hee
    • Pediatric Infection and Vaccine
    • /
    • v.3 no.2
    • /
    • pp.163-167
    • /
    • 1996
  • Aseptic meningitis, the most common infection of the central nervous system, is an acute illness mostly caused by enteroviruses. Cerebrospinal fluid(CSF) has been used for the detection of enteroviral RNA but the detection has been mostly performed in a single CSF specimen obtained during the illness. A major objective was to evaluate the relation of sampling time to the recovery of enteroviral RNA in CSF. Thirty seven CSF specimens were obtained from 24 patients between May and August 1993, when an outbreak of asceptic meningitis by echovirus type 9 occurred. Enteroviral RNA in CSF was detected by polymerase chain reaction(PCR). Data about onset of symptom development were obtained by review of medical records. Enteroviral RNA was detected by PCR in 29 of 37 CSF specimens. PCR yielded positive results in 4 of 5 CSF specimens obtained on day 1 to 3, 10 of 11 on day 4 to 6, 8 of 10 on day 7 to 9, 6 of 8 on day 10 to 12, 1 of 3 on day 13 to 15 postonset. Of 11 patients from each of whom more than one CSF were obtained on different day postonset, PCR yielded positive resutls in 2 of 3 cases in whom enteroviral RNA detection was negative in the first CSF. These results indicate that two or more CSF specimens obtained within 12 days postonset are required for improving the accuracy of the diagnosis of enteroviral meningitis.

  • PDF

HPLC-tandem Mass Spectrometric Analysis of the Marker Compounds in Forsythiae Fructus and Multivariate Analysis

  • Cho, Hwang-Eui;Ahn, Su-Youn;Son, In-Seop;Hwang, Gyung-Hwa;Kim, Sun-Chun;Woo, Mi-Hee;Lee, Seung-Ho;Son, Jong-Keun;Hong, Jin-Tae;Moon, Dong-Cheul
    • Natural Product Sciences
    • /
    • v.17 no.2
    • /
    • pp.147-159
    • /
    • 2011
  • A high-performance liquid chromatography-electrospray ionization-tandem mass spectrometric method was developed to determine simultaneously eight marker constituents of Forsythiae fructus, and subsequently applied it to classify its two botanical origins. The marker compounds of Forsythia suspensa were phillyrin, pinoresinol, phillygenin, lariciresinol and forsythiaside; those of F.viridissima were arctiin, arctigenin and matairesinol. Separation of the eight analytes was achieved on a phenyl-hexyl column (150${\times}$2.0 mm i.d., 3 ${\mu}M$) using gradient elution with the mobile phase: (A) 10% acetonitrile in 0.5% acetic acid, (B) 40% aqueous acetonitrile. A few fragment ions specific to the types of lignans, among the product ions generated by collisonally induced dissociation (CID) of molecular ion clusters, such as [M-H]$^-$ or [M+OAc]$^-$ were used not only for fingerprinting analysis but for the quantification of each epimer by using multiple-reaction monitoring mode. It was shown good linearity ($r^2{\geq}$ 0.9998) over the wide range of all analytes; intra- and inter-day precisions (RSD, %) were within 9.14% and the accuracy ranged from 84.3 to 115.1%. The analytical results of 40 drug samples, combined with multivariate statistical analyses - principal component analysis (PCA) and hierarchical cluster analysis (HCA) - clearly demonstrated the classification of the test samples according to their botanical origins. This method would provide a practical strategy for assessing the authenticity or quality of the herbal drug.

MWCNT, silver nanoparticles, CuBTC를 사용한 염소 이온 센서 합성

  • Gwak, Byeong-Gwan;Park, Su-Bin;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.101-101
    • /
    • 2018
  • Quantitative measurement of chloride ion concentration has an important role in various fields of electrochemistry, medical science, biology, metallurgy, architecture, etc. Among them, its importance of architecture is ever-growing due to unexpected degradations of building structure. These situations are caused by corrosion of reinforced concrete (RC) structure of buildings. And chloride ions are the most powerful factors of RC structure corrosion. Therefore, precise inspection of chloride ion concentration must be required to increase the accuracy of durability monitoring. Multi-walled Carbon nanotubes (MWCNTs) have high chemical resistivity, large surface area and superior electrical property. Thus, it is suitable for the channels of electrical signals made by the sensor. Silver nanoparticles were added to giving the sensing property. CuBTC, one of the metal organic frameworks (MOFs), was employed as a material to improve the sensing property because of its hydrophilicity and high surface area to volume ratio. In this study, sensing element was synthesized by various chemical reaction procedures. At first, MWCNTs were functionalized with a mixture of sulfuric acid and nitric acid because of enhancement of solubility in solution and surface activation. And functionalized MWCNTs, silver nanoparticles, and CuBTC were synthesized on PTFE membrane, one by one. Electroless deposition process was performed to deposit the silver nanoparticles. CuBTC was produced by room temperature synthesis. Surface morphology and composition analysis were characterized by scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS), respectively. X-ray photoelectron spectroscopy (XPS) was also performed to confirm the existence of sensing materials. The electrical properties of sensor were measured by semiconductor analyzer. The chloride ion sensing characteristics were confirmed with the variation of the resistance at 1 V.

  • PDF

Analysis of Sexed Sperm by Flow Cytometry in Hanwoo (Korean Native Cattle)

  • Yoo, Han-Jun;Lee, Kyung-Jin;Lee, Yong-Seung;Yoon, Pil-Sang;Park, Joung-Jun;Kim, Hyeong-Cheol;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • This study evaluated a sexed sperm ability to produce embryos by flow cytometer. Hanwoo bulls sperm were separated to X and Y sperm via Hoechst 33342 stained with near UV laser or performed the pre-sorted without near UV laser beam in flow cytometry. Pre-sorted sperm had significantly higher viability ($84{\pm}1.15%$, $p$<0.05) compared to other sorted groups in frozen-thawed semen. For fresh semen, pre-sorted sperm had the higher viability ($79{\pm}3%$, $p$<0.05) than those of the X and Y sperm ($44.7{\pm}1.67$ and $41.7{\pm}1.2%$) separated by differences of DNA content. On the other hand, pre-sorted and X sperm sorted according to differences in DNA content had significantly higher viabilities ($24.3{\pm}1.2$ and $25.7{\pm}0.9%$, $p$<0.05) compared to that of the sorted Y sperm ($13.7{\pm}1.2%$) in the hypoosmotic swelling test. The proportion acrosome reaction in the sorted X sperm was higher ($55.0{\pm}1.7$ and $45.0{\pm}1.5%$) than those of the sorted Y-sperm ($32.3{\pm}0.9%$, $p$<0.05). However, the sperm morphologies of the sorted groups were not significantly differences. In conclusion, the sex-sorting procedure by flow cytometry affected some characteristics of Hanwoo sperm. Further study is needed to determine the optimal procedures to enhance male and female embryos and sorting accuracy.

Touch Noise Reduction using Kalman Filter and Pre-emphasis (프리엠퍼시스와 칼만 필터를 이용한 터치 잡음 제거)

  • Yu, Seung-wan;Song, Byung Cheol
    • Journal of Broadcast Engineering
    • /
    • v.20 no.4
    • /
    • pp.568-579
    • /
    • 2015
  • Recently, mobile devices with touch display panel are widely used. Accuracy and reaction speed of touch signal are very important in touch devices. Therefore, we need to develop an effective algorithm to reduce touch noise quickly and accurately. This paper proposes a touch noise reduction algorithm using Kalman filtering in consideration of signal motion. First, a specific pre-emphasis processing is applied to an input signal so as to maximize the effect of Kalman filtering. In other words, a pure signal in the touch signal increases but noise in the touch signal decreases. Next, motion of the signal is detected. Motion estimation is performed only if motion is detected. If we detect motion by using the only neighborhood of the signal, we can reduce about 75% of the computation in comparison with examining the entire area. Finally, Kalman filtering using the previous state of current signal is performed. Experimental results show that the proposed algorithm suppresses touch noise sufficiently without degradation of the pure signal

Protein Disorder/Order Region Classification Using EPs-TFP Mining Method (EPs-TFP 마이닝 기법을 이용한 단백질 Disorder/Order 지역 분류)

  • Lee, Heon Gyu;Shin, Yong Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.6
    • /
    • pp.59-72
    • /
    • 2012
  • Since a protein displays its specific functions when disorder region of protein sequence transits to order region with provoking a biological reaction, the separation of disorder region and order region from the sequence data is urgently necessary for predicting three dimensional structure and characteristics of the protein. To classify the disorder and order region efficiently, this paper proposes a classification/prediction method using sequence data while acquiring a non-biased result on a specific characteristics of protein and improving the classification speed. The emerging patterns based EPs-TFP methods utilizes only the essential emerging pattern in which the redundant emerging patterns are removed. This classification method finds the sequence patterns of disorder region, such sequence patterns are frequently shown in disorder region but relatively not frequently in the order region. We expand P-tree and T-tree conceptualized TFP method into a classification/prediction method in order to improve the performance of the proposed algorithm. We used Disprot 4.9 and CASP 7 data to evaluate EPs-TFP technique, the results of order/disorder classification show sensitivity 73.6, specificity 69.51 and accuracy 74.2.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION (복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고-)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

Effect of Active Change of Foot Progression Angle on Lower Extremity Joint During Gait (보행 시 의도적인 발 디딤 각도 변화가 하지 관절 부하에 미치는 영향)

  • Go, Eun-Ae;Hong, Su-Yeon;Lee, Ki-Kang;An, Keun-Ok
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.85-90
    • /
    • 2013
  • Efficient gait is compensate for a lack of exercise, but the wrong walking can cause disease that joints, muscles, brain and body structure(Scott & Winter, 1990). Also many researchers has been studied gait of positive mechanism using analytical methods kinetic, kinematic. This study is to identify nature of knee adduction moment, depending on different foot progression angle and the movement of rotation of pelvis and body. Health study subject conducted intended walking with three different angles. The subjects of this study classified three types of walking; walk erect, pigeon-toed walk and an out-toed gait. Ten university students of K without previous operation and disease record selected for this study. For accuracy of this study, three types of walking carried out five times with 3D image analysis and using analysis of ground reaction force to analyze nature of knee adduction moment and the movement of rotation of pelvis and body. Firstly, the HC(heel contact) section value of intended walk erect, pigeon-toed walk and an out-toed gait was not shown statistically significant difference but TO(toe off) section value was shown that the pigeon-toed walk statistically significant. The value of pigeon-toed walk was smallest knee adduction moment(p< 0.005). Secondly, X axis was the change of rotation movement body and pelvis when walk erect, pigeon-toed walk and an out-toed gait. Shown statistically Y axis was not shown statistically significant but Z axis statistically significant(p<0.05). These result show the significant differences on TO section when walking moment reaches HC, it decides the walking types and rotates the foot.

High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Won-Woong;Lee, Sun-Young;Yu, Se Mi;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3727-3734
    • /
    • 2012
  • An analytical method has been developed for the rapid determination of perfluorinated compounds (PFCs) in human serum samples. The extraction and purification of PFCs from human serum were performed by the modified method of previous report. Ten PFCs were rapidly separated within 3.3 min by C18-monolithic column liquid chromatography (LC) and detected by electrospray ionization (ESI) tandem mass spectrometry (MS/MS) in negative ion mode. The runtime of PFCs on monolithic column LC was up to 4-fold faster than that on conventional column LC. The effect of triethylamine (TEA) to the mobile phase has investigated on the overall MS detection sensitivity of PFCs in ESI ionization. Quantification was performed by LC-MS/MS in multiple-ion reaction monitoring (MRM) mode, using $^{13}C$-labeled internal standards. Method validation was performed to determine recovery, linearity, precision, and limits of quantification, followed by, the analysis of a standard reference material (SRM 1957 from NIST). The overall recoveries ranged between 81.5 and 106.3% with RSDs of 3.4 to 16.2% for the entire procedure. The calibration range extended from 0.33 to 50 $ng\;mL^{-1}$, with a correlation coefficient ($R^2$) greater than 0.995 and the limits of quantification with 0.08 to 0.46 $ng\;mL^{-1}$. This approach can be used for rapid and sensitive quantitative analysis of 10 PFCs in human serum with high performance and accuracy.