• Title/Summary/Keyword: Re-engineering

Search Result 3,564, Processing Time 0.031 seconds

An appropriateness review on the road tunnel ventilation standards by pollutants site measurement and case study (오염물질 현장측정 및 사례조사를 통한 도로터널 환기기준의 적정성에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.323-335
    • /
    • 2020
  • In this study, a series of site measurement of particulate and gases pollutants at five tunnels were carried out along with case studies to review the suitability of the current road tunnel ventilation design standards. Previous studies by other researchers have shown that the ratios of the level of measurement to the standard were 27.9%, 1.6% and 3.4% for TSP, CO and NOx, respectively. Those measured in this site study shows even lower ratios; the ratios were 2.6%, 0.8% and 0.3%, for TSP, CO and NOx, respectively. The particle size analysis of TSP for the five tunnels shows that PM10 including tire wear and re-suspended road dust exceeded 20.4%. This implies that non-exhaust particulate matter must be taken into account, since the current design standards for the particulate matter (visibility) include only the engine emission. Based on the recent research results, for vehicle emission rate and slope-speed correction factors, revision of ventilation design standards for pollutants is required. WRA (PIARC) also emphasizes the necessity of the ventilation design standards for pollutants. In addition, enactment of a new road tunnel ventilation system operation standard or guideline is strongly recommended when considering the low operating rate of the ventilation system with jet-fans.

Estimation of Water Quality Improvement and Reduction of Influent Pollution by Installation of Water Treatment System Filled with Bio-stone Ball (바이오스톤 볼 수처리 시스템에 의한 오염물질 저감 및 저수지의 수질개선효과 산정)

  • Choi, Sunhwa;Kim, Heungseop;Chung, Sewoong
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.471-482
    • /
    • 2019
  • Water treatment system filled with Bio-stone Ball (BSB) have been developed for the purification of polluted water in many rivers and lakes. The real-scale plants of BSB water treatment system was constructed for field application test and water purification evaluation in Maewha reservoir. The average water purification efficiencies of BSB watertreatment system shows BOD 70.3% (47.2~97.4%), COD 45.3% (26.1~64.7%), TOC 19.2% (8.5~50.0%), SS 82.8% (73.1~92.7%), Chl-a 80.4% (57.2~91.8%), TN 23.2% (6.4~39.5%), and TP 51.8% (-1.1~80.1%). BSB water treatment system shows very high at 70~80% in the water purification efficiencies of BOD, Chl-a, and SS. The average of pollution loading reduction by installation of BSB treatment system shows 39.2% for COD and 16.8% for TP. The water quality improvement rates (%) of the Maewha reservoir shows TOC 14.5%, COD 14.5%, Chl-a 12.5% and TP 25.1%. The BSB watertreatment system can be applied to many agricultural reservoirs and major rivers to deal with serious water pollution issues.

Application of Information Flow Statistics to Micrometeorological Data to Identify the Ecosystem State (생태계의 상태 파악을 위한 정보 흐름 통계의 미기상학적 자료에의 적용)

  • Kim, Sehee;Yun, Juyeol;Kang, Minseok;Chun, Junghwa;Kim, Joon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2013.11a
    • /
    • pp.26-27
    • /
    • 2013
  • 산림생태계의 에너지, 물질, 정보의 교환 과정과 그 변화를 이해하려면 먼저 생태계의 구조와 기능이 어떻게 상호작용하는지를 이해해야 한다. 생태계의 기능은 한, 두 가지의 특징에 의해서만 이루어지는 것이 아니다. 그렇기 때문에 그 기능을 파악하고 적절히 이용하거나 대응하기 위해서는 한 생태계와 주변 환경 전체를 바라볼 수 있는 시스템 사고가 필요하다. 이에 우리는 생태계의 '구조'를 파악함으로써 생태계의 '상태'를 이해하고자 한다. 본 연구에서는 Ruddell and Kumar (2009)의 접근법을 따라, 어떻게 한 생태계의 상태를 파악할 수 있는가라는 질문을 광릉활엽수림에 적용하여 답하고자 한다. 즉, 우리는 산림생태계가 열린 복잡계라고 가정하고, 생태계 내에서 다양한 프로세스들 간의 시시각각 변하는 네트워크의 구조가 각 시점의 시스템의 상태를 나타내는 지표가 될 수 있다고 가정하였다. 이 연구에서는 그 구조적 특징을 정량화하여 나타내는데 초점을 맞추었다. 각각의 프로세스를 대표하는 상태 변수들 간의 정보 흐름의 양과 방향, 시간 규모를 계산해냄으로써 네트워크 구조를 파악하고자 하였다. 온대 산악지형 활엽수림인 GDK의 2008년 순생태계교환량(NEE), 총일차생산량(GPP), 생태계호흡량(RE), 현열플럭스(H), 잠열플럭스(LE), 하향단파복사(Rg), 강수량(Precipitation), 기압(Pressure), 기온(T), 포차(VPD)의 시계열 자료를 월별로 나누어 최장 18 시간 규모의 정보 흐름을 계산하였다. 정보 흐름의 구조를 파악하기 위하여 변수들 간의 전이엔트로피(Transfer entropy)와 상호정보(Mutual Information)를 계산하는 방법을 사용하였다. 또한 시계열 자료를 이용함으로써 변수들 간에 정보가 전달되는 시간 규모의 특성을 파악할 수 있었다. 최종적으로, 계산한 정보 흐름을 시각화하여 프로세스 네트워크 구조를 나타내었다. 결과는 월별로 생태계의 정보 흐름의 종류, 방향과 시간 규모, 그에 따른 프로세스 간 상호 작용의 특징 등을 보여준다. 이를 통해 계절적 환경 변화에 따라 시스템의 네트워크 구조와 상태가 어떻게 변화하는지 이해할 수 있을 것이다. 이 연구는 추후 우리 연구실에서 생산한 8 년 자료에 적용함으로써 다양한 날씨 및 기후변화와 환경 변화에 따라 생태계의 구조와 상태가 어떻게 변화하는지 연구하는 시작점이 될 것이다. 이 접근법은 단위나 차원에 무관하게 다양한 종류의 자료에 적용할 수 있는 반면에, 일관성 있게 정의된 시스템의 상태 및 그 상태를 구성하는 주요 하부 시스템들의 네트워크 상태를 이해하는데 이용될 수 있다. 본 연구는 비평형 열역학과 복잡계의 관점에서 바라 본 시스템 사고를 적용하려 하는 여러 연구 분야에 새로운 도전을 촉발할 좋은 선행연구가 될 것이라 기대된다.

  • PDF

Effect of Ultrasound Irradiation during Cementation Process for Recovery of Iridium (이리듐 회수를 위한 시멘테이션 공정 중 초음파 조사의 영향)

  • Kim, Seunghyun;Kim, Young-Jin;Seo, Jun-Hyung;Cho, Jin-Sang;Cho, Kye-Hong;Lee, Jaeryeong
    • Resources Recycling
    • /
    • v.30 no.6
    • /
    • pp.61-67
    • /
    • 2021
  • This work investigated the cementation of iridium from iridium-containing hydrochloric acid leachate. Zinc powder was used as the reducing agent, and the effects of the stoichiometric ratio of Zn/Ir, initial Ir concentration, initial pH, reaction time, and ultrasound irradiation on iridium recovery were investigated. When only the stirrer was used for cementation, the iridium recovery increased with the addition amount of zinc, and the recovery of about 70% at 40 times the stoichiometric ratio of Zn/Ir. In contrast, when employing ultrasonic irradiation with stirring, the recovery of iridium decreased at 20 times or less the stoichiometric amount of zinc. The recovery of iridium increased at 40 times the stoichiometric ratio of Zn/Ir. This result may be due to the ionization of zinc and re-dissolution of iridium during the ultrasound irradiation treatment. When a combination of ultrasonic irradiation and stirring was used for cementation, the iridium recovery increased by more than 27% compared to that when using only the stirrer. It was possible to recover 99% of iridium under the following conditions: reaction time, 60 min; initial pH, 0.01; volume of leachate, 100 mL; 1770 ppm Ir, 40 times the stoichiometric ratio of Zn/Ir.

Development of Human Resource Management Program for Protected Horticulture (시설재배 인력관리 프로그램 개발)

  • Myung, Dong-Ju;Shin, Gyung-Ho;Lee, Jeong-Hyun;Kim, Eun Ji;Lee, Beom-Seon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.359-366
    • /
    • 2021
  • This study aimed to develop and verify the smart human resource management (HRM) program in a large scale greenhouse. HRM program delivers detailed work orders to workers and gathers work results by mobile phone application. Greenhouse managers can monitor the workload, work speed, quality of employee by HRM program and can analyse performance easily. Greenhouse Managers can set the work speed including 'twisting', 'trimming' and 'harvesting' in a greenhouse. It makes planning work schedule and assigns resources to each specific job easier. Therefore, the manager can arrange the number of employees to promote work performance and also easy to estimate the labor shortage. Greenhouse managers can evaluate the adequacy of the number of employees through job performance analysis by period and adjusts the supply/demand ratio of regular and non-regular employees. The HRM program can improve work efficiency by announcing the real-time work performance of all employees on a monitor screen to induce competition among workers and re-educate unripe employees who accomplish behind average to improving work skills.

A study on combination of loss functions for effective mask-based speech enhancement in noisy environments (잡음 환경에 효과적인 마스크 기반 음성 향상을 위한 손실함수 조합에 관한 연구)

  • Jung, Jaehee;Kim, Wooil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.3
    • /
    • pp.234-240
    • /
    • 2021
  • In this paper, the mask-based speech enhancement is improved for effective speech recognition in noise environments. In the mask-based speech enhancement, enhanced spectrum is obtained by multiplying the noisy speech spectrum by the mask. The VoiceFilter (VF) model is used as the mask estimation, and the Spectrogram Inpainting (SI) technique is used to remove residual noise of enhanced spectrum. In this paper, we propose a combined loss to further improve speech enhancement. In order to effectively remove the residual noise in the speech, the positive part of the Triplet loss is used with the component loss. For the experiment TIMIT database is re-constructed using NOISEX92 noise and background music samples with various Signal to Noise Ratio (SNR) conditions. Source to Distortion Ratio (SDR), Perceptual Evaluation of Speech Quality (PESQ), and Short-Time Objective Intelligibility (STOI) are used as the metrics of performance evaluation. When the VF was trained with the mean squared error and the SI model was trained with the combined loss, SDR, PESQ, and STOI were improved by 0.5, 0.06, and 0.002 respectively compared to the system trained only with the mean squared error.

A Study on the Productivity and Efficiency Comparative Analysis of Container Terminal in Busan New Port (부산신항 컨테이너터미널 효율성 및 생산성 비교 분석)

  • Kang, Seok-Han;Nam, Jung-Woo;Sim, Min-Seop;Kim, Yul-Seong
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.138-147
    • /
    • 2021
  • The need for analysis of the operational efficiency and productivity of the Busan Port Container Terminal is increasing because of the Hanjin Shipping's bankruptcy and the re-establishment of the Maritime Alliance. This paper analyzes the efficiency and productivity of five Busan New Port Container Terminal companies by using the DEA analysis and Malmquist productivity index model based on the port construction disclosure data and the collected terminal internal data. According to the analysis, the average efficiency of the five container terminals increased in 2018 but declined slightly in 2019, and the Malmquist index showed that all terminals except A have advanced productivity. Additionally, relative to facility productivity, operators at the North Container Terminal had higher facility productivity than operators at the Busan New Port Nam Container Terminal, and regarding capital productivity, the D terminal ported by HMM, a national shipping company, was the highest in facility productivity. Regarding labor productivity, the C terminal showed the highest productivity, and regarding ship work productivity, the A terminal showed the highest productivity.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Development of Optimal Antiviral Coating Method for the Air Filtration System of Subway Station (지하역사 승강장 공조 시스템 필터용 항바이러스 코팅 성능 및 재생 성능 평가)

  • Park, Dae Hoon;Hwang, Jungho;Shin, Dongho;Kim, Younghun;Lee, Gunhee;Park, Inyong;Kim, Sang Bok;Hong, Keejung;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • In this study, a novel antiviral coating method for the air filtration system of subway station was investigated. Using dry aerosol coating process, we developed a high-performance antiviral air filter with spark discharger and carbon brush type ionizer. Silver nanoparticles were produced by a spark discharge generation system with ion injection system and were used as antiviral agents coated onto a medium grade air filter. The pressure drop, filtration efficiency, and antiviral ability of the filter against aerosolized MS2 virus particles as a surrogate of SARS-CoV-2 virus were tested with dust contamination. Dust contamination caused the increase of the filtration efficiency and pressure drop, while the antiviral agents (in this study, silver nanoparticles) coating did not have any significant effect on the filtration efficiency and pressure drop. Using these properties, we suggested a novel method to maximize the antiviral performance of the antiviral air filter that was contaminated by dust particles. Moreover theoretical analysis of antiviral ability with dust contamination and re-coated antiviral agents was carried out using a mathematical model to calculate the time-dependent antiviral effect of the filter under actual conditions of subway station. Our model can be used to apply on antiviral air filtration system of subway station for prevention of pandemic diffusion, and predict the life cycle of an antiviral filter.

A Study of the Regeneration of Spent GAC using an Electrochemical Method (전기화학적 방법을 이용한 Spent Granular Activated Carbon (GAC)의 재생 연구)

  • Lee, Sangmin;Joo, Soobin;Jo, Youngsoo;Oh, Yeji;Kim, Hyungjun;Shim, Intae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.481-491
    • /
    • 2022
  • This study investigates the characteristics of the GAC adsorption behavior during the operation of a multi-stage cross-flow filtration and GAC adsorption process for the purpose of devising an advanced treatment of combined sewer overflows (CSOs) and evaluates the regeneration efficiency of spent GAC that has reached the design breakpoint. During the filtration process, suspended substances are easily removed, but dissolved organic substances are not removed, necessitating a process capable of removing dissolved organic substances for the advanced treatment of CSOs. In general, GAC adsorption has been applied under low-concentration organic conditions, such as for water purification and tertiary treatments of sewage, and has rarely been applied under conditions with high organic concentrations, such as with sewage or CSOs. Accordingly, this study will provide a new and interesting experience. Also in this study, the continuous operation and breakthrough characteristics of GAC according to the strength of the inflow organic matter were investigated, electrochemical regeneration was applied to the used GAC, and the regeneration efficiency was evaluated through desorption and re-adsorption tests. The results showed that the breakthrough period was 21 days under high concentration conditions, 28 days at medium concentrations, and 32 days under low concentration conditions. The desorption of adsorbed organic matter through electrolysis occurred in the range of 188 to 609 mgCOD/L depending on the electrolysis conditions, and the effect of the electrolyte type led to the finding that NaOH was slightly higher than H2O2.