• Title/Summary/Keyword: Rays

Search Result 2,309, Processing Time 0.033 seconds

Radiation Adaptive Response Induced by I-131 Therapy in Patients with Differentiated Thyroid Cancer (분화 갑상선암 환자에서 I-131 치료에 의해 유도되는 방사선적응반응)

  • Li, Ming-Hao;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.83-88
    • /
    • 2001
  • Purpose: The purpose of this study was to ascertain whether radiation adaptive response could be induced by high dose I-131 therapy in patients with differentiated thyroid cancer. Materials and Methods: Lymphocytes from 21 patients (7 males, 14 females, mean age $55{\pm}12$ years) were collected before and after administration of 5,550 MBq (150 mCi) I-131. They were exposed to a challenge dose of 1 Gy gamma rays using a Cs-137 cell irradiator. The number of ring-form (R) and dicentric (D) chromosomes was counted under the light microscope, and used to calculate the frequency of chromosomal aberration. Ydr, which was defined as the sum of R and D divided by the total number of counted lymphocytes. Results: Ydr in patients before I-131 therapy ($0.09{\pm}0.01$) was not different from that of controls ($0.08{\pm}0.01$). Ydr was significantly increased to $0.13{\pm}0.02$ (p<0.0001) after I-131 therapy. Increase of Ydr after the challenge irradiation of 1 Gy was significantly lower in patients after I-131 therapy than before I-131 therapy ($0.17{\pm}0.03\;vs\;0.21{\pm}0.02$, p<0.0001). Cycloheximide (CHM), an inhibitor of protein synthesis, abolished this effect. Ydr after CHM ($0.20{\pm}0.01$) was significantly higher than Ydr after I-131 therapy ($0.17{\pm}0.03$, p<0.0001), but was not different from Ydr before I-131 therapy ($0.21{\pm}0.02$).Conclusion: High dose I-131 therapy induces an adaptive response in peripheral lymphocytes of patients with well-differentiated thyroid cancer, which is associated with protein synthesis.

  • PDF

THE COMPARATIVE ANALYSIS OF THE DENTITION AND MORPHOLOGIC MALOCCLUSION OF THE TEMPOROMANDIBULAR DYSFUNCTION PATIENT (측두하악장애를 가진 교정환자 교합의 형태학적 특성에 관한 연구)

  • Kim, Mee-Ae;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.53-63
    • /
    • 1996
  • In order In analyze the occlusion of TMD patient, 73 casts and post eroanterior cephalometric X-rays of patients showing TMD symptoms at first interview were measured and compared that of 30 non-patients . Horizental overjet, vertical overbite, openbite, crossbite, depth of curve of Spee, midline deviation, facial asymmetry, attrition, and TPI were measured and processed statistically The results could be summarized as follows, 1. TMD group showed the highest prevalence in twenties, teens, and before 9 years old group in order, and more prevalent in female than male. 2. There were no statistically significance between two groups of overjet and overbite measurements, but showed significance of 6 classification of anterior tooth relationship between two groups TMD groups. 3. n group had more anterior openbite than normal group but there were no statistically significance between two groups. 4. Anterior crossbite was more prevalent in normal group brit posterior crossbite was more prevalent in TMD group. 5. TMD group showed deeper curve of Spee and there were statistically significance between two groups. 6. TMD group had more attrition than normal group and there were statistically significance beween two groups. 7 TMD group showed more facial asymmetry than normal group. 8. TPI did not showed statistical significance beween two groups. According to the above results, TMD group showed severe and complex mode of malocclusion and this should be carefully regarded when treatment planning and during the treatment of malocclusion.

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams (유리선량계를 이용한 고에너지 전자선 측정 이용 가능성에 관한 연구)

  • Son, Ki-Hong;Jung, Hai-Jo;Shin, Sang-Hun;Lee, Hyun-Ho;Lee, Sung-Hyun;Kim, Mi-Sook;Ji, Young-Hoon;Kim, Kum-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; $R^2$ of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was ${\pm}1.2%$. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from $0^{\circ}$ to $90^{\circ}$ and GD's maximum response differencewas 14% lower at 180o. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within ${\pm}1.5%$ except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.

Synthesis and Structural Characterization of Benzene-sorbed Cd2+-Y(FAU) Zeolite (벤젠이 흡착된 Cd2+-Y(FAU) 제올라이트의 합성 및 구조연구)

  • Moon, Dae Jun;Suh, Jeong-Min;Park, Jong Sam;Choi, Sik Young;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.45-57
    • /
    • 2017
  • Two single crystals of fully dehydrated $Cd^{2+}$-exchanged zeolites Y were prepared by the exchange of ${\mid}Na_{75}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$ ($Na_{75}-Y$, Si/Al = 1.56) with aqueous $0.05M\;Cd(NO_3)_2$ (pH = 3.65) at 294 K, followed by vacuum dehydration at 723 K (crystal 1) and a second crystal, similarly prepared, was exposed to zeolitically dried benzene for 72 hours at 294 K and evacuated (crystal 2). Their structures were determined crystallographically using synchrotron X-rays and were refined to the final error indices using $F_o$>$4{\sigma}(F_o)$ of $R_1/wR_2=0.040/0.121$ and 0.052/0.168, respectively. In crystal $1({\mid}Cd_{36}H_3{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions primarily occupy sites I and II, with additional $Cd^{2+}$ ions at sites I', II', and a second site II. In crystal $2({\mid}Cd_{35}(C_6H_6)_{24}H_5{\mid}[Si_{117}Al_{75}O_{384}]-FAU)$, $Cd^{2+}$ ions occupy five crystallographic sites. The 24 benzene molecules are found at two distinct positions within the supercages. The 17 benzene molecules are found on the 3-fold axes in the supercages where each interacts facially with one of site IIa $Cd^{2+}$ ions. The remaining 7 benzene molecules lie on the planes of the 12-rings where each is stabilized by multiple weak electrostatic and van der Waals interactions with framework oxygens.

Egg Development and Larvae of the Rose Bitterling Rhodeus ocellatus (KNER) (흰줄납줄개의 난발생과 부화자어)

  • KIM Yong Uk;PARK Yang Seong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.586-593
    • /
    • 1985
  • The rose bitterling, Rhodeus ocellatus (KNER) is commonly distributed in the fresh waters of Korea and Japan. On January 15, February 15, and March 18 in 1984, mature adults of rose bitterling were caught in the watercourse of Maeri, Kimhae, South Korea. The authors fertilized the eggs employing dry method in the laboratory on May 7, 16 and 25 in 1984. Hatched larvae were reared in small aquariums at $17{\sim}25.5^{\circ}C$ (average around $21.2^{\circ}C$). Mollusks, Anodonta woodiana in the gill chamber of which, rose bitterling lay eggs were caught in order to study natural spawning of the rose bitterling in the same watercourse. The eggs of this species are not adhesive and demersal. The size of the eggs varies from 2.54 to 2.75mm in long diameter and 1.45 to 1.65mm in short diameter. The eggs are cylindrical in form when they are extruded from ovipositor, immediately after entering water, but they acquire their distinctive form of a greatly elongated pear. Hatching took place in ca. 39 hours after fertilization. The newly hatched larvae were $2.65{\sim}2.70mm$ in total length possessing yolk sac and 13-14 myotomes. Thirteen days after hatching, the prelarvae attained 6.5 mm in total length, and the first melanophores appeared on the head, and the anterior part and sides of the yolk sac. One month after hatching, the postlarvae attained 8.5mm. in total length and emerged from the gills of the mollusks. Then the yolk sac was completely resorbed. Two months after hatching, the rose bitterling attained 14.4mm in total length, and entered the fingerling period of life. All the rays already present were the D. III, 11-12, A. III, 11-12, P. 10, V. 7. and a distinguishing, feature is the presence of a black pigment spot in the lobe of the dorsal fin.

  • PDF

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

Different Expressions of HIF-$1\alpha$, Bcl-2 and Baxin DU145 Prostate Cancer Cells Transplanted in Nude Mouse between X-Ray and Neutron Irradiation (누드마우스에 주입된 DU-145 전립샘암에서 엑스선과 중성자선에 의한 HIF-$1\alpha$, Bcl-2, Bax 발현의 차이)

  • Kong, Moon-Kyoo;Kang, Jin-Oh;Kim, Sang-Ki;Shin, Dong-Oh;Park, Seo-Hyun;Kim, Chang-Ju;Chang, Hyun-Kyung
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.218-227
    • /
    • 2009
  • Purpose: To investigate the radiobiologic effects of neutron and X-ray irradiation on DU-145 prostate carcinoma cells by identifying the differences of HIF-$1\alpha$ expression and apoptosis. Materials and Methods: Nude mice were injected with the human prostate cancer cell line, DU-145, and then irradiated with 2 Gy and 10 Gy X-rays, or 0.6 Gy and 3.3 Gy neutrons, respectively. The mice were sacrificed at 24 hours and 120 hours after irradiation. The expression levels of HIF-$1\alpha$, Bcl-2 and Bax were compared with immunohistochemical staining and western blotting. The apoptotic indexes were compared with the Terminal deoxynucleotidyl biotin-dUTP nick and labeling (TUNEL) assay. Results: At day 1, HIF-$1\alpha$ and Bcl-2 expression decreased, while Bax expression and the number of TUNEL positive cells increased in neutron irradiated groups for the control and X-ray irradiated groups. The Bcl-2/Bax ratio was significantly lower in the neutron irradiated groups regardless of dose (p=0.001). The same pattern of the differences in the expressions of the HIF-$1\alpha$, Bcl-2, Bax, Bcl-2/Bax ratio, and apoptotic indexes were indentified at day 5. HIF-$1\alpha$ expression was related with Bcl-2 (p=0.031), Bax (p=0.037) expressions and the apoptotic indexes (p=0.016) at day 5. Conclusion: Neutron irradiation showed a decrease in HIF-$1\alpha$, Bcl-2 expression, and Bcl-2/Bax ratio, but increased Bax expression regardless of dose. This study suggests that the differences radiobiological responses between photon and neutron irradiation may be related to different HIF-$1\alpha$ expression and subsequent apoptotic protein expressions.