• Title/Summary/Keyword: Rays

Search Result 2,309, Processing Time 0.024 seconds

The Effect of Benzophenone Derivatives on the Shielding of Ultraviolet Rays and Light-fastness of the Dyed Fabrics (벤조페논 유도체의 자외선 차단 효과 및 염색물의 일광견뢰도에 미치는 영향)

  • 김종규;김태경;박태수;임용진
    • Textile Coloration and Finishing
    • /
    • v.10 no.4
    • /
    • pp.53-61
    • /
    • 1998
  • The absorptions of ultraviolet rays of benzophenone derivatives were investigated in terms of the position of substituent, especially hydroxyl group. When the derivatives were added to the aqueous solution of Rhodamin B, which has very low light-fastness, all of them delayed the photofading of Rhodamin B solution. But on the fabrics, only the derivatives with the hydroxyl group at 2-position showed the good ability of ultraviolet rays absorption. The benzophenone derivatives absorb ultraviolet rays to form a hydrogen bond between hydroxyl group and carbonyl group, and return to their original structure by releasing heat energy. In solution, the derivatives can form a intermolecular hydrogen bond, and absorb the ultraviolet rays. But on the fabric, the intermolecular hydrogen bond is impossible, only hydroxyl group of 2-position forms a intramolecular hydrogen bond, and that makes the derivatives on the fabric absorb ultraviolet rays.

  • PDF

LONGITUDINAL WAVES, STORING AND AMPLIFYING CAPABILITY OF INFORMATION IN WATER MOLECULES AND QUANTUM RESONANCE SPECTROMETER

  • Oh, Hung-Kuk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.18-28
    • /
    • 1996
  • The outer-most electrons of metal atoms and the remaining valence electrons of any molecular atoms make three-dimensional crystallizing $\pi$-bondings. The rotating electrons on the three-dimensional crystallizing $\pi$-bonding orbitals of atoms make $\pi$-far infrared rays. Longitudinal wave is a propagation of a bundle of $\pi$-far infrared rays, which are produced by a dynamic impact on a solid bar. The $\pi$-far infrared rays make three-dimensional crystallizing $\pi$-bondings in the material, which reproduce the same $\pi$-far infrared rays. If a current signal is input into water molecules under a given electric potential field with $\pi$-far infrared rays (input information), the signal can be amplified because the $\pi$-far infrared rays make the $\pi$-bondings, which reduce electric resistance. The three-dimensional crystallizing $\pi$-bondings can induce normal electrons to move from one orbital to next one with a aid of potential electric field. Quantum Resonance Spectrometer is composed of tesla coil absorbing $\pi$-far infrared rays, tesla coil emitting varying electromagnetic waves signal generator, signal storage, human body amplifier, signal analyzer and data indicator. The absorbing tesla coil making varying magnetic field and downward and upward electric field, which resonates the $\pi$-far infrared rays coming out from specimen and absorbs them. The modulated current signal from the input square signal can generate and emit varying electromagnetic waves from the tesla coil. The varying electro-magnetic waves make the three-dimensional crystallizing $\pi$-bondings and the $\pi$-far infrared rays in the water molecules.

  • PDF

Effects of Combined Irradiation of Neutrons and ${\gamma}$-Rays on the Pink Mutation Frequencies in Tradescantia (중성자와 감마선 중복 조사가 자주달재비 분홍돌연변이율에 미치는 영향)

  • Kim, Jin-Kyu;Lee, Young-Keun;Kim, Jae-Sung;Shin, Hae-Shick;Hyun, Soung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.67-73
    • /
    • 2000
  • The effects of combined irradiation of neutrons and ${\gamma}$-rays were analysed by means of Tradescantia stamen hair (TSH) assay. Potted plants were irradiated with $0{\sim}2$ Gy of ${\gamma}$-rays. For the combined treatments, the plants were irradiated with neutrons from $^{252}Cf$ 24 hours before or after ${\gamma}$-irradiation. The slopes of dose-response curves were 5.98, 6.17 and 7.48, in ${\gamma}$-rays, ${\gamma}$-rays+neutrons, and neutrons+${\gamma}$ -rays irradiated groups, respectively. The biological efficacy of radiations in the induction of pink mutations increased by 25% in neutrons+${\gamma}$-rays irradiated group, while it increased by 12% in ${\gamma}$-rays+neutrons irradiated group. The combined irradiation with two kinds of radiations results in the different efficacy of radiation depending on the order of irradiations, which is of great importance in the related fields such as sterilization and radiotherapy.

  • PDF

A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography (X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

A Study on the Relationship between Ultraviolet Rays and Skin Color Using a Photoplethysmography Sensor

  • So-Yae Hur;Sun-Jib Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.1
    • /
    • pp.363-369
    • /
    • 2023
  • In this study, to check the function of managing the severity of ultraviolet rays with a smart watch, a popular health care IT device, It was tested whether measuring heart rate using a PPG(Photoplethysmography) sensor representatively used in a smart watch could tell skin changes caused by ultraviolet rays. Through this experiment, we examined the possibility that the skin color tanned by ultraviolet rays can be determined only by the heart rate measurement function of the PPG sensor. In addition, the possibility of expanding the heart rate measurement function of the PPG sensor to the use of skin condition management was considered. we used an Arduino-based reflective PPG sensor to measure changes in heart rate by selecting body sites with high and low UV rays exposure. A significant value was derived through tests considering factors such as gender, UV exposure, and age. As a result, the study identified the possibility of adding ultraviolet rays and skincare items to future smart watch healthcare items and the possibility of expanding skin measurement methods. It is also possible to suggest the direction of future research.

ELEMENTAL TRANSMUTATION BY ENER(OR BROWN) GAS TREATMENT

  • Guk, O-Heung
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.219-220
    • /
    • 2001
  • Each atom is enclosed with $\pi$-rays, which were produced by the alternating magnetic field that is made by the electron's going and returning between atoms. If some resonant $\pi$-rays are supplied to and suppress the fencing $\pi$-rays, the bonding will be broken because the equilibrium distance for the electron moving between atoms can not be maintained. Electrolysis process supplies $\pi$-rays of Gibb's free energy to the reactant atoms and then the component atoms are divided into and are induced to both electric poles. (omitted)

  • PDF

RESOLUTION OF AIR POLLUTIONAL GASES BY ENER(or BROWN) GAS

  • Guk, O-Heung
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.217-218
    • /
    • 2001
  • Each atom is enclosed with $\pi$-rays, which were produced by the alternating magnetic field that is made by the electron's going and returning between atoms. If some resonant $\pi$-rays are supplied to and suppress the fencing $\pi$-rays, the bonding will be broken because the equilibrium distance for the electron moving between atoms can not be maintained. Electrolysis process supplies $\pi$-rays of Gibb's free energy to the reactant atoms and then the component atoms are divided into and are induced to both electric poles. (omitted)

  • PDF

Energetic Nonthermal Particles ('Cosmic-Rays') & Their Acceleration in Collisionless Plasmas

  • JONES T. W.
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.4
    • /
    • pp.225-230
    • /
    • 2001
  • Rarefied cosmic plasmas generally do not achieve thermodynamic equilibria, and a natural consequence of this is the presence of a significant population of charged particles with energies well above those of the bulk population. These are exemplified by the galactic cosmic rays, but the importance of these high energy populations extends well beyond that context. I review here some of the basic issues associated with the propagation and acceleration of cosmic rays, especially in the context of collisionless plasma shocks.

  • PDF

Review of the Hidden Rays of Diffraction

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • A high-frequency analysis technique, called the hidden rays of diffraction (HRD), is reviewed in this paper. The physical optics and the rigorous diffraction coefficients of a perfectly conducting wedge illuminated by a plane wave are compared. The physical existence of hidden rays on the shadow boundary is explained in view of the geometric theory of diffraction (GTD). In particular, a systematic tracing of hidden rays and its visualization are precisely described by introducing the concept of the supplementary boundary. The physical meaning of the null-field condition in the complementary region is also explained.

The Value of X-ray Compared with Magnetic Resonance Imaging in the Diagnosis of Traumatic Vertebral Fractures

  • Lee, Yang Woo;Jang, Jae Ho;Kim, Jin Joo;Lim, Yong Su;Hyun, Sung Youl;Yang, Hyuk Jun
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.158-165
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of X-rays in patients with acute traumatic vertebral fractures visiting the emergency department and to analyze the diagnostic value of X-rays for each spine level. Methods: We retrospectively analyzed basal characteristics by reviewing medical records of 363 patients with adult traumatic vertebral fractures, admitted to the emergency center from March 1, 2014 to February 28, 2017. We analyzed spine X-rays and magnetic resonance imaging (MRI) scans to determine distribution according to the vertebral level, and we evaluated the efficacy of X-rays by comparing discrepancies between X-rays and MRI scans. Results: For a total of 363 patients, the mean age was 56.65 (20-93) and 214 (59%) were males. On the basis of X-rays, 67 cases (15.1%) were of the cervical spine, 133 cases (30.0%) were of the thoracic spine, and 243 cases (54.9%) were of the lumbar spine. In particular, the thoracolumbar region (T11-L2) was the most common, with 260 cases (58.7%). In X-rays, fractures were the least in the upper thoracic region (T1-T3), whereas MRI scans revealed fairly uniform distribution across the thoracic spine. Sensitivity of X-rays was lowest in the upper thoracic spine and specificity was almost always greater than 98%, except for 94.7% in L1. Positive predictive value was lower in the mid-thoracic region (T4-T9) and negative predictive value was slightly lower in C6, T2, and T3 than at other sites. Diagnostic accuracy of X-rays by vertebral body, transverse process, and spinous process according to fractured vertebral structures was significantly different according to vertebral level. Conclusions: Diagnostic accuracy of X-rays was lower in the upper thoracic region than in other parts. Further studies are needed to identify better methods for diagnosis considering cost and neurological prognosis.