• Title/Summary/Keyword: Ray-sum

Search Result 56, Processing Time 0.028 seconds

The usability analysis of the Ray-sum technique and SSD (Shaded Surface display) technique in stomach CT Scan (위장 CT 검사에서 Ray-sum 기법과 SSD(Shaded Surface Display) 기법의 유용성 분석)

  • Kim, Hyun-Joo;Cho, Jae-Hwan;Song, Hoon
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.151-156
    • /
    • 2011
  • The analysis and image evaluation the Ray-sum technique and Shaded Surface Display (under SSD) technique which is the reconstruction image processing technique after the CT scan was evaluated and the usability of the three-dimensional information offering was confirmed in the patient with stomach cancer. After obtaining the raw data by using 64-MDCT in 20 patient with stomach cancers, the image reconstruction processing was done. It was evaluated to describe accurately the analyzed result Ray-sum and SSD reconstruction image everyone anatomical structure. In the precision estimation of the image, the lesion location could coincide in the Ray-sum and SSD reconstruction image majority with the gastro fiberscope and we can know than the gastro fiberscope over 6cm that there was the error. In addition, We could know that degree of accordance of the results of the image interpretation about the lesion and endoscope and pathological opinion were high.

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

Cosmic Ray Flux Variation Estimated from the Raw Solar Images

  • Oh, Suyeon;Park, Hyungmin;Park, Keunchan;Chae, Jongchul;Yi, Yu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.96.2-96.2
    • /
    • 2013
  • The solar images are taken by the CCD detectors of the Sun monitoring satellites. The solar images are constructed after removing the traces of cosmic rays on the raw CCD data files. Thus, while applying the method of removing the cosmic rays traces, we can estimate the cosmic rays flux by counting the number of traces. The cosmic ray flux in the steady state might be the sum of the solar and galactic cosmic rays. However, the abrupt change in the flux could be assumed to be originated from the Sun. Therefore, we can identify the solar origins of the sudden solar cosmic ray flux changes from the phenomena shown in the processed solar images taken by SOHO/EIT. As the results, the estimated cosmic ray flux in the steady state is the anti-correlated with sunspot numbers, which shows the minima in cosmic ray flux at the solar cycle maxima defined by the sunspot numbers. The profiles of estimated solar cosmic ray associated with the ground level enhancements have the significant increase in the cosmic ray flux with good correlation. Thus, the solar images are valuable data useful in estimating the solar cosmic ray long term and transient flux variations.

  • PDF

Optical system design for recognition of human iris (홍채인식용 광학계 설계)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.390-394
    • /
    • 2000
  • An optical system for iris pattern recognition of the human eye is designed. The lens system is triplet type, and characterized to minimize longitudinal chromatic aberration and Petzval sum. The distance from object to image is 200 mm-300 mm and the effective focal length is 50 mm. Performance of the imaging system is assessed by calculating the ray-fan and spot diagram for Fraunhofer C, d and F line for object height 0 mm, 4 mm and 6 mm. Furthermore, MTFs are calculated. All of the spot sizes are less than 0.05 mm in diameter. The MTF values are higher than 0.5 in the spatial frequency range up to 20 lines/mm for all of the object heights. ights.

  • PDF

Prediction of Wind Farm Noise with Atmospheric Stability (대기 안정 상태에 따른 풍력 단지 소음 전파 예측)

  • Son, Eunkuk;Lee, Seunghoon;Jeon, Minu;Lee, Soogab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.42.2-42.2
    • /
    • 2011
  • Noise generated from wind turbines has been predicted by numerical methods. Sound pressure level(SPL) on the turbines is predicted after aerodynamic analysis is carried out by Wind Turbine Flow, Aeroacoustics and Structure analysis (WINFAS) code. The level of each panel of acoustic sphere is determined by the sum of tonal, turbulence ingestion and airfoil self noise. With the noise source database, the acoustic sphere, SPL on the ground is calculated using the model based on acoustic ray theory. The model has been designed to consider the effects on the condition of terrain and atmosphere. The variations of SPL on the ground occur not only because of the different source level but also because of the nonuniform distributions of the sound speed along the height. Hence, the profile of an effective sound speed which is the sum of the contribution of sound speed to a temperature gradient and a wind speed variation is used by the theory based on atmospheric stability. With the integrated numerical method, the prediction of sound propagation on the wind farm is carried out with the states of the atmospheric stability.

  • PDF

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

FIRST PRINCIPLE CALCULATIONS OF MCD SPECTRA FOR SANDWICHED Co(110) SYSTEMS

  • Hong, Soon-C.;Lee, Jae-Il;Wu, R.;Freeman, A.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.575-578
    • /
    • 1995
  • X-ray magnetic-circular-dichroism (MCD) spectra, orbital ($$) and spin magnetic moments ($$) for Co(110) monolayers a free standing mode or sandwiched between Pd(Pd/1Co/Pd)and Cu layers (Cu/1Co/Cu) are calculated using the thin film full potential linearized augmented plane wave energy band method. In contrast to the double peak structure predicted for the Co(0001) surface, only a minor side peak is found in the MCD spectra for Cu/Co/Cu, while MCD spectra for the other systems show a single peak structure. The MCD sum rules originally derived from a single ion model are found in the band approach to be valid for the systems investigated. However, for the spin sum rule, the magnetic dipole term ($$) is not negligible and needs to be included.

  • PDF

Background Removal and ROI Segmentation Algorithms for Chest X-ray Images (흉부 엑스레이 영상에서 배경 제거 및 관심영역 분할 기법)

  • Park, Jin Woo;Song, Byung Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.105-114
    • /
    • 2015
  • This paper proposes methods to remove background area and segment region of interest (ROI) in chest X-ray images. Conventional algorithms to improve detail or contrast of images normally utilize brightness and frequency information. If we apply such algorithms to the entire images, we cannot obtain reliable visual quality due to unnecessary information such as background area. So, we propose two effective algorithms to remove background and segment ROI from the input X-ray images. First, the background removal algorithm analyzes the histogram distribution of the input X-ray image. Next, the initial background is estimated by a proper thresholding on histogram domain, and it is removed. Finally, the body contour or background area is refined by using a popular guided filter. On the other hand, the ROI, i.e., lung segmentation algorithm first determines an initial bounding box using the lung's inherent location information. Next, the main intensity value of the lung is computed by vertical cumulative sum within the initial bounding box. Then, probable outliers are removed by using a specific labeling and the pre-determined background information. Finally, a bounding box including lung is obtained. Simulation results show that the proposed background removal and ROI segmentation algorithms outperform the previous works.

Propagation Study of the Shadow Region by Roof-top Building ana Tree in B-WLL (B-WLL에서 지붕형 건물 및 나무에 의한 전파 음영 지역 해석)

  • 채찬병;박성욱;서경환;정한욱;이재원
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.809-812
    • /
    • 1999
  • This paper presents the radio propagation effects in the shadow region due to the presence of obstacle, like building and tree, along the path at the B-WLL band. Using the Uniform Theory of Diffraction(UTD), the total field was obtained as the sum of contributions with diffraction ray from the each obstacle's edge, the direct ray, and the reflected rays from ground. The normalized signal level(in ㏈) is calculated with the parameters of the base station elevation and the distance between obstacle and receiver. This results are used to provide the suitable radio cell planning and coverage prediction in the area of shadow region.

  • PDF

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield (140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가)

  • Kim, Ji-Young;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.