• Title/Summary/Keyword: Ray Path

Search Result 213, Processing Time 0.024 seconds

Component-Based System Reliability using MCMC Simulation

  • ChauPattnaik, Sampa;Ray, Mitrabinda;Nayak, Mitalimadhusmita;Patnaik, Srikanta
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.2
    • /
    • pp.79-89
    • /
    • 2022
  • To compute the mean and variance of component-based reliability software, we focused on path-based reliability analysis. System reliability depends on the transition probabilities of components within a system and reliability of the individual components as basic input parameters. The uncertainty in these parameters is estimated from the test data of the corresponding components and arises from the software architecture, failure behaviors, software growth models etc. Typically, researchers perform Monte Carlo simulations to study uncertainty. Thus, we considered a Markov chain Monte Carlo (MCMC) simulation to calculate uncertainty, as it generates random samples through sequential methods. The MCMC approach determines the input parameters from the probability distribution, and then calculates the average approximate expectations for a reliability estimation. The comparison of different techniques for uncertainty analysis helps in selecting the most suitable technique based on data requirements and reliability measures related to the number of components.

An atypical case involving real, ghost, and pseudo-ghost images on a panoramic radiograph

  • Jong-Won Kim;Yo-Seob Seo
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • Purpose: This report presents a unique case featuring real, ghost, and pseudo-ghost images on the panoramic radiograph of a patient wearing earrings. It also explains the formation of these images in an easy-to-understand manner. Materials and Methods: One real image and two ghost images appeared on each side of a panoramic radiograph of a patient wearing earrings on both sides. Of the two ghost images on each side, one was considered a typical ghost image and the other was considered a ghost-like real image (pseudo-ghost image). The formation zones of the real, double, and ghost images were examined based on the path and angles of the X-ray beam from the Planmeca ProMax. To simulate the pseudo-ghost and typical ghost images on panoramic radiography, a radiopaque marker was affixed to the right mandibular condyle of a dry mandible, and the position of the mandible was adjusted accordingly. Results: The center of rotation of the Planmeca ProMax extended beyond the jaw area, and the area of double image formation also reached beyond the jaw. The radiopaque-marked mandibular condyle, situated in the outwardly extending area of double image formation, exhibited triple images consisting of real, double (pseudo-ghost), and ghost images. These findings helped to explain the image formation associated with the patient's earrings observed in the panoramic radiograph. Conclusion: Dentists must understand the characteristics and principles of the panoramic equipment they use and apply this understanding to taking and interpreting panoramic radiographs.

A Commissioning of 3D RTP System for Photon Beams

  • Kang, Wee-Saing
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.119-120
    • /
    • 2002
  • The aim is to urge the need of elaborate commissioning of 3D RTP system from the firsthand experience. A 3D RTP system requires so much data such as beam data and patient data. Most data of radiation beam are directly transferred from a 3D dose scanning system, and some other data are input by editing. In the process inputting parameters and/or data, no error should occur. For RTP system using algorithm-bas ed-on beam-modeling, careless beam-data processing could also cause the treatment error. Beam data of 3 different qualities of photon from two linear accelerators, patient data and calculated results were commissioned. For PDD, the doses by Clarkson, convolution, superposition and fast superposition methods at 10 cm for 10${\times}$10 cm field, 100 cm SSD were compared with the measured. An error in the SCD for one quality was input by the service engineer. Whole SCD defined by a physicist is SAD plus d$\sub$max/, the value was just SAD. That resulted in increase of MU by 100${\times}$((1_d$\sub$max//SAD)$^2$-1)%. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth in uniform medium of relative electron density (RED) 1, PDDs for 4 algorithms of dose calculation, Clarkson, convolution, superposition and fast-superposition, were compared with the measured. The calculated PDD were similar to the measured. For 10${\times}$10 cm open field, 1 m SSD and at 10 cm depth with 5 cm thick inhomogeneity of RED 0.2 under 2 cm thick RED 1 medium, PDDs for 4 algorithms were compared. PDDs ranged from 72.2% to 77.0% for 4 MV X-ray and from 90.9% to 95.6% for 6 MV X-ray. PDDs were of maximum for convolution and of minimum for superposition. For 15${\times}$15 cm symmetric wedged field, wedge factor was not constant for calculation mode, even though same geometry. The reason is that their wedge factor is considering beam hardness and ray path. Their definition requires their users to change the concept of wedge factor. RTP user should elaborately review beam data and calculation algorithm in commissioning.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Development and Application of Inquiry Modules for Instruction for the Concept of Straight propagation of Light (빛의 직진 개념 지도를 위한 탐구 학습모듈의 개발 및 적용)

  • Kim, Kyu Hwan;Kim, Jung Bog
    • Journal of Science Education
    • /
    • v.35 no.2
    • /
    • pp.173-192
    • /
    • 2011
  • The purpose of this study was to develop inquiry modules for learning straight propagation of light, to verify their efficiency, and to acquire implications. this study proposes teaching modules for improvements of light experiments, which were developed in this work. Inquiry modules were applied to 75 school teachers(8 elementary school teachers, 67 middle school and high school teachers) for examining that the modules make teachers have the scientific concepts. Then, conception changes were analyzed except 5 teachers who responded poorly. The pre-test result shows that most teachers have alternative conceptions, which is that they thought the bright shape on apparatus's bottom panel itself shown in the textbook as evidence for the path of light's straight propagation. The post-test result shows this alternative conception was changed into scientific conception. Unlikely pretest, most teachers' conception was changed into the scientific conception that the light come from a light source. Teachers are able to express that the light beam comes from a miniature electric bulb. Further more, most teachers can draw light's path correctly; from the miniature electric bulb, through vertical panel having a hole, to the apparatus bottom.

  • PDF

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge (임플란트 CT에서 방향 표시자의 방향과 잔존골을 고려한 임플란트 식립 방향의 관계에 관한 연구)

  • Kim Do-Hoon;Heo Min-Suk;Lee Sam-Sun;Oh Sung-Ook;Choi Hang-Moon;Jeon In-Seong;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.79-83
    • /
    • 2003
  • Purpose : To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. Materials and Methods: The study materials consisted of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix/sup (R)/ software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. Results: The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the indicating rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Conclusion: Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  • PDF

Analysis of dose from surface to near the buildup region in the therapeutic X-ray beam (표피로 부터 buildup 영역까지 흡수되는 암치료용 방사선의 선량분석)

  • Vahc, Young-Woo
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.41-50
    • /
    • 1995
  • The absorbed dose and contaminant electron distribution of therapeutic X-ray beam (15MV photon) was studied with a half blocked beams of 30$\times$30$\textrm{cm}^2$ and field size ranging from 5$\times$5 to 30$\times$30$\textrm{cm}^2$. For a 15MV photon beam energy, the value of the depth of dose maximum, d$_{max}$, gradually decrease with increasing field size from 5$\times$5 to 30$\times$30$\textrm{cm}^2$ due to mainly by contaminant electrons which are produced in the flattening filter and scattered by collimator jaws, tray holder〔Lucite〕, blocking block and air. The results suggest that separate dosimetry data should be kept for blocked and unblocked field. The inherence of the contaminant electrons to the open field depth of maximum dose can lead to mistaken results if attenuation measurements are made at that depth. A nurmerous contaminant electrons mainly were distributed as shape of corn in the central photon beam and their path length in the water were shorter than 30mm because of the electrons energy having around 6MeV. These results clearly appears that the substraction of scattered electrons (electrons and positrons) from the total depth dose curve not only lowers the absolute dose in the bulidup region and surface dose, it also causes a shift of d$_{max}$ to a deeper depth. In the terapeutic high energy photon beam, the absorbed dose near the buildup region is the combined result of incident contaminant electrons and phantom generated electronsrons.

  • PDF

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.

Synthesis of ceria by combination of spray pyrolysis, postheat, and ball-milling and its characterization (분무열분해, 후소성 및 볼밀링을 조합한 방법을 이용한 세리아의 합성 및 특성연구)

  • Kim, Hyun-Ik;Kim, Sang Pil;Song, Jae-Kyung;Kim, Sang Hern
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1057-1072
    • /
    • 2018
  • In this study, micro-sized $CeO_2$ particles were synthesized by spray pyrolysis, and EG(ethylene glycol) and CA(citric acid) as organic additives were added to obtain hollow and porous particle during spray pyrolysis, and characteristics of obtained ceria were investigated according to the amount of added organic additives. Spray pyrolysis, postheat and ball-milling were combined to give 6 paths. $CeO_2$ nano-sized particle was obtained by the path which has sequence of Spray Pyrolysis with 0.5 M of EG and CA${\rightarrow}$Post-heat${\rightarrow}$Ball-milling${\rightarrow}$Post-heat among 6 paths. The average particle size(24 nm with standard deviation of 3.8 nm) of $CeO_2$ nano-sized particle by TEM analysis is close to the primary particle size(20 nm) which was calculated by Debye-Scherrer equation. To investigate the morphological characteristics and structure of the synthesized nanoparticle powders, SEM(Scanning Electron Microscopy), XRD(X-Ray Diffractometer) and TEM(Transmission Electron Microscopy) were used.