• Title/Summary/Keyword: Ray

Search Result 20,515, Processing Time 0.048 seconds

Implementation and Evaluation of 2D Ray-Tracing Technique for Indoor Propagation Characteristics Modeling (실내 전파특성 모델링을 위한 2차원 광선추적법 구현 및 평가)

  • Jeong, Seung-Heui;Kang, Chul-Gyu;Oh, Chang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.4
    • /
    • pp.454-460
    • /
    • 2007
  • In this paper, we implemented a ray-tracing simulator with a ray-launching technique and generated the propagation path of each ray in an multiple-wall indoor environment. In this simulator, we adopted two dimension ray-tracing techniques considering the reflection and penetration were dominant propagation factor in the indoor channel. From the result, we verified that this ray-tracing simulator shows the similar pattern and delay distribution with the experiment results of the previous research.

  • PDF

The dark-current and X -ray sensitivity measurement of hybrid digital X-ray detector having dielectric layer structure (a-Se 기반의 혼합형 X-선 검출기에서 유전층의 누설전류 저감효과)

  • Seok, Dae-Woo;Park, Ji-Koon;Joh, Jin-Wook;Lee, Dong-Gil;Moon, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.31-34
    • /
    • 2002
  • In this paper, the electric properties of amophous selenium multilayer samples has been investigated. In order to develop the hybrid flat-panel digital· X-ray image detector, we measured and analyzed their performance parameters such as the X -ray sensitivity and dark-current for a amophous selenium multilayers X-ray detector with a phosphor layer, The hybrid digital X-ray image detector can be constructed by integrating a phosphor layer (or a scintillative layer) that convert X-ray to a light on a-Se photoconduction mulilayers that convert a light to electrical signal. As results, the dielectric materials such as parylene between the phosphor layer and the top electrode may reduce the dark-current of the samples. Amorphous selenium multilayers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation (방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF

Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system (X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

Development of X-ray PIV Technique and its Application to Blood Flow (X-ray PIV 기법의 개발과 혈액 유동에의 적용연구)

  • Kim, Guk Bae;Lee, Sang Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1182-1188
    • /
    • 2005
  • An x-ray PIV (Particle Image Velocimetry) technique was developed to measure quantitative information on flows inside opaque conduits and on opaque-fluid flows. At first, the developed x-ray PIV technique was applied to flow in an opaque Teflon tube. To acquire x-ray images suitable for PIV velocity field measurements, refraction-based edge enhancement mechanism was employed using detectable tracer particles. The optimal distance between with the sample and detector was experimentally determined. The resulting amassed velocity field data were in reasonable agreement with the theoretical prediction. The x-ray PIV technique was also applied to blood flow in a microchannel. The flow pattern of blood was visualifed by enhancing the diffraction/interference -bas ed characteristic s of blood cells on synchrotron x-rays without any contrast agent or tracer particles. That is, the flow-pattern image of blood was achieved by optimizing the sample (blood) to detector distance and the sample thickness. Quantitative velocity field information was obtained by applying PIV algorithm to the enhanced x-ray flow images. The measured velocity field data show a typical flow structure of flow in a macro-scale channel.

Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film (필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The x-ray transmission anode Ag-target tube was developed to apply for the thickness measurement of film in the thickness range of several tens$\sim$several hundreds ${\mu}m$ and its characteristics were evaluated. The energy distribution and dose of x-ray from Ag-target tube was investigated at the tube voltage near 10 kV, and discussed in comparition with that from W-target tube. The energy distribution and dose of x-rays passing through film were measured with various thickness of Ny and PP film. From these results, it was confirmed that our x-ray tube can be applied for the thickness measurement of film.

Real-time Ray-tracing Chip Architecture

  • Yoon, Hyung-Min;Lee, Byoung-Ok;Cheong, Cheol-Ho;Hur, Jin-Suk;Kim, Sang-Gon;Chung, Woo-Nam;Lee, Yong-Ho;Park, Woo-Chan
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.2
    • /
    • pp.65-70
    • /
    • 2015
  • In this paper, we describe the world's first real-time ray-tracing chip architecture. Ray-tracing technology generates high-quality 3D graphics images better than current rasterization technology by providing four essential light effects: shadow, reflection, refraction and transmission. The real-time ray-tracing chip named RayChip includes a real-time ray-tracing graphics processing unit and an accelerating tree-building unit. An ARM Ltd. central processing unit (CPU) and other peripherals are also included to support all processes of 3D graphics applications. Using the accelerating tree-building unit named RayTree to minimize the CPU load, the chip uses a low-end CPU and decreases both silicon area and power consumption. The evaluation results with RayChip show appropriate performance to support real-time ray tracing in high-definition (HD) resolution, while the rendered images are scaled to full HD resolution. The chip also integrates the Linux operating system and the familiar OpenGL for Embedded Systems application programming interface for easy application development.

Investigating X-ray cavities and the environmental effects

  • Shin, Jaejin;Woo, Jong-Hak;Mulchaey, John S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.34.2-34.2
    • /
    • 2016
  • X-ray cavities are typically detected as surface brightness depression in X-ray diffuse emission from hot gas in high resolution X-ray images (i.e., Chandra and XMM-Newton). Showing the coincidence of location with radio jets, X-ray cavities imply that the radio jets interact with interstellar/intergalactic medium. It is important to understand them since they can be a clue of understanding AGN feedback to their host galaxies. To understand the physics of the AGN feedback, X-ray cavity has been actively studied while there are only a few statistical studies on X-ray cavity based on small or incomplete samples. Hence, a systematic study with a large sample is needed. With the condition of sufficient X-ray photons to detect surface brightness depression, we constructed a large sample of 133 galaxy clusters, galaxy groups, and individual galaxies to investigate X-ray cavities. We detected 201 cavities from 94 objects using two detection methods (i.e., beta-modeling and unsharp masking method), and confirmed the cavity size-distance relation over a large dynamical range. The size-distance relation does not vary for different environments (i.e., galaxy cluster, groups, and individual galaxies), suggesting that there is little environmental effect on the formation of X-ray cavity.

  • PDF

Implementation of a Integrated Network for Vehicle by Using FlexRay Gateway (FlexRay 게이트웨이를 이용한 차량용 통합 네트워크 구현)

  • Park, Jang-Sik;Kim, Hyun-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2670-2674
    • /
    • 2010
  • FlexRay is a new standard of network communication system which provides a high speed serial communication, time triggered bus and fault tolerant communication between electronic devices for future automotive applications. The speed of FlexRay is 10 times higher than that of CAN. In this paper, FlexRay module is implemented using MC9S12XF512 micro-controller and gateway converting CAN message to FlexRay message. It is shown that the implemented system operates successfully.

Implementation of Ray Tracing Processor for the Parallel Processing (병렬처리를 위한 고속 Ray Tracing 프로세서의 설계)

  • Choe, Gyu-Yeol;Jeong, Deok-Jin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.636-642
    • /
    • 1999
  • The synthesis of the 3D images is the most important part of the virtual reality. The ray tracing is the best method for reality in the 3D graphics. But the ray tracing requires long computation time for the synthesis of the 3D images. So, we implement the ray tracing with software and hardware. Specially we design the hit-test unit with FPGA tool for the ray tracing. Hit-test unit is a very important part of ray tracing to improve the speed. In this paper, we proposed a new hit-test algorithm and apply the parallel architecture for hit-test unit to improve the speed. We optimized the arithmetic unit because the critical path of hit-test unit is in the multiplication part. We used the booth algorithm and the baugh-wooley algorithm to reduce the partial product and adapted the CSA and CLA to improve the efficiency of the partial product addition. Our new Ray tracing processor can produce the image about 512ms/F and can be adapted to real-time application with only 10 parallel processors.

  • PDF