• Title/Summary/Keyword: Ray

검색결과 20,430건 처리시간 0.044초

Chandra Archival Survey of Galaxy Clusters: Surface Photometry of Diffuse X-ray Emission

  • 김은혁;김민선
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.77.2-77.2
    • /
    • 2012
  • We have studied the physical properties of X-ray point sources in galaxy clusters for years based on the archival observations using the most sophisticated space X-ray observatory, Chandra X-ray Observatory. Because the ultimate goal of the study is comparing the physical properties of X-ray point sources found in galaxy clusters to those in X-ray blank fields; blank fields are the regions in the sky where any noticeable cosmic diffuse X-ray emission is not observed, an important key issue regarding this study is picking out the point sources related with galaxy clusters. However we do not have red-shift information of all the X-ray point sources. Therefore as a first order approximation we will consider the point sources with smaller projected cluster-centric distance than the adopted size of galaxy clusters. As a first step of this study we perform X-ray surface photometry of ~600 galaxy clusters based on ~800 Chandra ACIS observations. We carefully investigate the radial structures of diffuse X-ray emission in 3 different energy bands. Based on the highly accurate surface photometry we determine the characteristic size of diffuse X-ray emission (i.e., the boundary of X-ray emission). We also investigate the cosmological evolution of this characteristic size of galaxy clusters. General discussion regarding the two dimensional morphology of galaxy clusters will be presented.

  • PDF

영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석 (The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area)

  • 김성규;손상혁
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

엑스선 촬영실의 공간산란선 발생 인자에 관한 연구 (A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room)

  • 나수경;한상효
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.393-399
    • /
    • 2009
  • 본 연구에서는 전리함을 이용하여 엑스선 촬영실 내에서 공간산란선량을 측정하고 산란선의 발생원과 조사 조건에 대한 산란율 의존성을 조사하였다. 아크릴 팬톰의 산란선 발생 인자를 조사하기 위해 관전압(40~140 kV)과 조사면($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$)에 대한 산란율 변화를 측정하였다. 조사면이 $35{\times}35\;cm^2$일 때 측방산란율은 3.11~4.5%로 측정되었다. 촬영실 내에서 팬톰, 콜리메이터, 엑스선관, 벽면에서 발생하는 산란선량의 영향을 측정하였는데 전체 관전압에 대해 팬톰의 산란선 발생률은 95.4% 이상이었으며 콜리메이터, 엑스선관, 벽면의 산란선 발생률은 각각 2.6%, 1.3%, 0.7% 이하로 나타났다. 관전압 100 kV, 40 mAs 조사 조건에서 촬영실 내 팬톰으로부터 1 m 거리에서 측정한 공간선량은 최대 2 mR 정도로 나타나 조사조건의 최적화 등의 산란선 경감조치가 필요할 것으로 생각된다.

  • PDF

FRP 복합재료의 T-Ray 비파괴특성 평가 및 적용 (Evaluation and Application of T-Ray Nondestructive Characterization of FRP Composite Materials)

  • 임광희
    • 비파괴검사학회지
    • /
    • 제30권5호
    • /
    • pp.429-436
    • /
    • 2010
  • 최근에는 T-ray(terahertz ray)를 이용한 비파괴기술이 새로운 분야로 주목을 받고 있다. 본 연구에서는 FRP 복합재료의 내재결함이나 레이업(lay-up) 특성을 검사 및 평가하기 위한 T-ray 시간영역 분광기(time-domain spectroscopy)를 활용하였으며 또한 이 T-ray 분광기의 일반적인 반사 및 투과모드를 이용하여 T-ray 이미지를 구현하였다. 특히, 2개의 톱날 인공결함이 내재한 GFRP 복합재의 평가방법을 제시하였다. CFRP 복합재료에 대해서는 T-ray 전파는 탄소섬유로 인해 진행 장해를 받는다. 이에 따라 T-ray의 전기장(E-field)의 방향과 탄소섬유 방향의 의존성을 분석하였다. 한편 인공결함인 알루미늄 테이프, 박리, 충격손상, 이물혼입 등을 T-ray를 이용하여 비파괴 검사 및 평가하였다. 이를 통해 FRP 복합재료의 T-ray비파괴평가의 적용 가능성 및 한계 등을 확인 할 수 있었다.

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

다층박막 거울을 이용한 단색 엑스선 획득 (Acquisition of Monochromatic X-ray Using Multilayer Mirror)

  • 천권수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.179-184
    • /
    • 2010
  • 나노 공간분해능을 갖는 영상을 얻기 위한 경엑스선 현미경 시스템에서는 단색 엑스선이 요구된다. 엑스선관에서 발생되는 화이트 빔으로부터 8.4 keV의 텅스텐 $L_{\alpha}$ 특성방사선을 84% 이상 반사시킬 수 있는 5.65 nm의 단위막 두께를 가지는 C/W 다층박막 거울을 설계하였고, 이온빔 스파터링 장치를 이용하여 $50{\times}50\;mm$ 크기로 제작하였다. 제작된 C/W 다층박막 거울은 99.5% 이상의 균일도(Uniformity)를 가지며, TEM 사진을 이용해 그 구조를 확인하였다. 8.05 keV의 구리 특성방사선을 광원으로 하는 엑스선 반사율 측정 장치를 이용한 다층박막 거울의 반사율을 측정함으로써 C/W 다층박막 거울의 8.4 keV에서의 반사율을 예상할 수 있었다. 제작된 C/W 다층박막 거울과 엑스선관을 이용하여 8.4 keV의 특성방사선을 획득함으로써 단색 엑스선을 획득하였다. 이때의 반사율은 77.1%였고, 단색 엑스선의 반치폭은 0.21 keV이었다. 엑스선관에서 높은 효율로 단색 엑스선을 획득할 수 있어 실험실 규모의 경엑스선 현미경 장치의 광원으로써 사용될 수 있는 가능성을 확인하였고, 다층박막 거울의 단위막 두께를 수 나노미터로 제작한다면 17.5 keV의 몰리브덴 특성방사선에 해당하는 단색 엑스선을 얻어 유방촬영에도 적용할 수 있을 것이다.

구름접촉을 하는 분말고속도공구강의 X선을 이용한 표면성상해석 (Analysis of Rolling Contact Surface on PM-High Speed Steel by X-ray Diffraction)

  • 이한영;김용진;배종수
    • Tribology and Lubricants
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2003
  • Recently, PM-high speed steel(PM-HSS) has reportedly been a good alternative material for rolling mill because of its superior performance to conventional HSS. This paper has been aimed to investigate the possibility for application to rolling contact element for PM-HSS by X-ray diffraction technique. The X-ray elastic constant for PH-HSS has been found by X-ray diffraction during the four-point bending test. Residual stress and half-value breadth on the contact surface during rolling contact fatigue process by X-ray diffraction have also been measured. The result of this study shows that the application of X-ray diffraction technique to PM-HSS could be as possible alternative material as conventional HSS. Half-value breadth on rolling contact surface by X-ray diffraction is not changed during rolling contact fatigue process. On the other hand, the residual stress is changed. This suggests that dislocation reaction has been hardly occurred in rolling contact, depending on super-saturated carbon in PM-HSS.

GALAXY CLUSTERS IN GAMMA-RAYS: AN ASSESSMENT FROM OBSERVATIONS

  • REIMER OLAF
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.307-313
    • /
    • 2004
  • Clusters of galaxies are believed to constitute a population of astrophysical objects potentially able to emit electromagnetic radiation up to gamma-ray energies. Evidence of the existence of non-thermal radiation processes in galaxy clusters is indicated from observations of diffuse radio halos, hard X-ray and EUV excess emission. The presence of cosmic ray acceleration processes and its confinement on cosmological timescales nearly inevitably yields in predicting energetic gamma-ray emission, either directly deduceably from a cluster's multifreqency emission characteristics or indirectly during large-scale cosmological structure formation processes. This theoretical reasoning suggests several scenarios to actually detect galaxy clusters at gamma-ray wavelengths: Either resolved as individual sources of point-like or extended gamma-ray emission, by investigating spatial-statistical correlations with unidentified gamma-ray sources or, if unresolved, through their contribution to the extragalactic diffuse gamma-ray background. In the following I review the situation concerning the proposed relation between galaxy clusters and high-energy gamma-ray observations from an observational point-of-view.

펄스파워용 X선제어 무도체스위치의 기본연구 (A Basic Study on X-ray Controlled Semiconductor Switch for Pulse Power)

  • Ko, Kwang-Cheol
    • 대한전기학회논문지
    • /
    • 제41권9호
    • /
    • pp.1013-1020
    • /
    • 1992
  • The conductivity variation of a high resistivity bulk silicon semiconductor, whose electrodes were deposited with aluminum vapor, was studied experimentally by measuring the X-ray intensity and current flow, which was developed by X-ray radiation while applying a pulse voltage to the silicon, in a load resistor connected to the semiconductor. The current flow observed immediately as the X-ray radiated, and when the X-ray decreased. It was found from the observation of switching current for the X-ray intensity and the voltage applied in the semiconductor that the switching current of the semiconductor increased as the intensity of the X-ray and the applied voltage increased. In case of lower applied voltage, the switching current for higher applied voltage depended on the intensity of the X-ray radiated due to the saturation of electron and hole.

  • PDF

X선 장치용 절연유의 방사선 유기전류에 관한 연구 (A Study on the Radiation Induced Current of X-ray Insulating Oil)

  • 김영일;정연택;이덕출
    • 대한전기학회논문지
    • /
    • 제38권7호
    • /
    • pp.549-556
    • /
    • 1989
  • Radiation induced current of the insulating oil used for X-ray tube housing was investigated in this paper. The X-ray induced current increased in proportion to the X-ray intensity and X-ray wave length and was greatly affected by the temperature of the insulating oil and the gap length` however, the current was not varied by the amount of the X-ray absorbed. The results suggest that one must consider the following problems as important factors for X-ray machine design and normal operation: cooling system of the X-ray tube housing, X-ray intensity, increasing temperature due to continuous operation, years used, and oil exchange and management.

  • PDF