Frequency Dependent Network Equivalent for Electromagnetic Transient Studies (전자기 과도현상 해석을 위한 주파수 의존 시스템 등가)

  • Wang, Yong-Peel;Jo, Keum-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1549-1555
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand. Moreover by using a well publicized test system and providing complete information on the developed FDNE coefficients other researchers easily benchmark their work against this.

The elastoplastic formulation of polygonal element method based on triangular finite meshes

  • Cai, Yong-Chang;Zhu, He-Hua;Guo, Sheng-Yong
    • Structural Engineering and Mechanics
    • /
    • v.30 no.1
    • /
    • pp.119-129
    • /
    • 2008
  • A small strain and elastoplastic formulation of Polygonal Element Method (PEM) is developed for efficient analysis of elastoplastic solids. In this work, the polygonal elements are constructed based on traditional triangular finite meshes. The construction method of polygonal mesh can directly utilize the sophisticated triangularization algorithm and reduce the difficulty in generating polygonal elements. The Wachspress rational finite element basis function is used to construct the approximations of polygonal elements. The incremental variational form and a von Mises type model are used for non-linear elastoplastic analysis. Several small strain elastoplastic numerical examples are presented to verify the advantages and the accuracy of the numerical formulation.

An apt material model for drying shrinkage and specific creep of HPC using artificial neural network

  • Gedam, Banti A.;Bhandari, N.M.;Upadhyay, Akhil
    • Structural Engineering and Mechanics
    • /
    • v.52 no.1
    • /
    • pp.97-113
    • /
    • 2014
  • In the present work appropriate concrete material models have been proposed to predict drying shrinkage and specific creep of High-performance concrete (HPC) using Artificial Neural Network (ANN). The ANN models are trained, tested and validated using 106 different experimental measured set of data collected from different literatures. The developed models consist of 12 input parameters which include quantities of ingredients namely ordinary Portland cement, fly ash, silica fume, ground granulated blast-furnace slag, water, and other aggregate to cement ratio, volume to surface area ratio, compressive strength at age of loading, relative humidity, age of drying commencement and age of concrete. The Feed-forward backpropagation networks with Levenberg-Marquardt training function are chosen for proposed ANN models and same implemented on MATLAB platform. The results shows that the proposed ANN models are more rational as well as computationally more efficient to predict time-dependent properties of drying shrinkage and specific creep of HPC with high level accuracy.

RFM으로 생성된 레이더 정사영상 자료의 정확도 분석

  • 이선일;김윤형;이규성
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2003.04a
    • /
    • pp.121-128
    • /
    • 2003
  • 사면관측 원리에 의해 획득되는 레이더 영상은 레이더파의 입사각도와 지표면의 경사도 및 방위각에 따라 기하학적 왜곡이 발생하게 된다. 전 국토의 70% 이상이 산악지형인 국내 여건을 감안한다면 레이더 영상의 정량적 활용을 위해서는 정밀한 기하보정이 반드시 필요하다. 본 연구에서는 RADSARSAT-1 SAR 영상에 대하여 세 가지 기하보정 방법을 적용하였다. 먼저 GCP 만을 이용한 단순기하보정을 수행하였고, 두번째로 위성의 자세와 위치정보 등을 이용하여 센서모델을 통한 보정을 하였다. 마지막으로 다양한 영상자료에 적용할 수 있는 RFM(Rational Function Model)을 이용하여 기하보정을 하였다. 이 세 가지 방법으로 기하보정된 레이더 영상의 위치정확도를 모의 레이더 영상과 비교 분석하였다. 또한 RFM을 이용한 보정결과를 검증하기 위하여 SIR-C 영상을 추가로 분석하였다.

  • PDF

Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies (전자기 과도현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가)

  • Wang, Yong-Pil;Jeong, Hyeong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.296-301
    • /
    • 2002
  • Modern power systems are very complex and to model them completely is impractical for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent AC system Equivalent (FDACSE) using Z-domain rational Function Fitting is presented and demonstrated. The FDACSE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This 1 & 2 port FDACSE have been applied to the New Zealand South Island AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 1 & 2 port FDACSE developed under different condition (linear load, fault and nonlinear loading). The study results have indicated the robustness and accuracy of 1 & 2 port FDACSE for electromagnetic transient studies.

A Study on the Estimation of the Fatigue Life Using the Stress Generated Models in the Steel Railroad Bridges (강철도교의 응력발생모형을 이용한 피로수명 추정에 관한 연구)

  • Yong, Hwan Sun;Kim, Seok Tae;Lee, Seong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.19-29
    • /
    • 1996
  • In this paper, it is presumed that the stress time history was generated by simulation method and investigated compatibility in regard to the reappearance of stress time history. In this procedure, the identified frequency distribution of stress range of the steel railroad bridge varies with the rational values of cut off point and bar width. Thus, we show variable aspect of the equivalent stress range results from change of cut off point and bar width. In addition, we analyze the variable of RMC and RMS model due to the cut off point and bar width of the measured stress history which influencs the prediction of fatigue life in the steel railroad bridge. The simulated stress time history is carried out by the superposition method incorporating the vertical load with rotation moment obtained from the Hermition interpolation function, and compared with developing stress results from measured maxi mum stress. Through this study, we can estimate the remaining fatigue life from a safety point of view and comparative accuracy.

  • PDF

Semi-resolution Practicability of Three-Dimensional Statics of Cables from Computer Programs

  • Dodaran, Asgar Ahadpour;Park, SangKil
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.1-6
    • /
    • 2012
  • The purpose of this paper is to present a rational method for analyzing, designing, or evaluating the spread mooring systems used with floating drilling units. This paper presents a validated model to calculate the catenary static configuration. A semi-resolution approach is presented in this paper that is capable of predicting the static performance of a caisson mooring system. The solution is derived as a function of only three parameters, which can be solved numerically by implementing different kinds of boundary conditions. The efficiency and accuracy of the method permit quick parametric studies for the optimal selection of the system particle, which is undoubtedly useful for a preliminary design. A number of numerical examples demonstrate the validity of the adopted approach. The paper contains a complete description of the test cases and reports the results in such a way that it can provide a "benchmark" test for users and programmers of computer codes for flexible riser analysis.

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

Frequency Dependend Network Equivalents to Electromagnetic Transient Simulation (주파수 의존 등가회로의 전자기 과도 현상 시뮬레이션)

  • Wang, Y.P.;Jo, K.S.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.592-593
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand.

  • PDF

A Study on the Internal Control System of Fisheries Cooperative (수산업협동조합의 내부통제제도에 관한 연구)

  • 박이봉;최정윤
    • The Journal of Fisheries Business Administration
    • /
    • v.22 no.2
    • /
    • pp.101-148
    • /
    • 1991
  • The fisheries cooperative (FC) performs the economic and nonprofitable activity to get the fundamental objective of enhancing cooperative members' economic and social position. The internal control system fitted for a local FC should be required for not only solving the resulting problem from the complexity of FC environment nowaday but also delegating authorities and performance from FC Federation to a local FC by implementing the local autonomy. The methodology of this study is to empirically test and to analyze the condition of FC internal control system (FCICS) by the questionnaire survey. The actual condition of FCICS in Korea is analyzed by the questionnaire and the detailed contents are as follows : (1) sending 208 questionnaire consisting of 162 questions, and receiving 92 replies from 39 manufactures (business firms) and 15 banks in Gyungnam and Pusan area and 25 FC and 13 agricultural cooperative (AC) in Korea, (2) the analyzed results of FC and AC are treated simultaneously. In the fundamentals of above analyzed results, the evaluation model of FCICS is tried to construct from the relationship between the financial condition of FC and the internal control elements through the stepwise regression method. (1) By the stepwise regression method, the number of FC officials $(X_1)$, the experimental number of regular auditing $(X_7)$, and auditing duty years $(X_8)$ are finally accepted as independent variables, (2) and the final model becomes $Y=-1.53526+0.34455X_1+0.24513X_7+0.16585X_8$/ and this model explains to the extent of 47.826%. From the above study, following proposals are to be suggested: (1) The function and problem of internal control in FCICS is able to be improved by enforcing the function of FCICS and enriching the management's recognition of FCICS (2) The cooperative president can bring up good FC by the rational operation of FCICS according to the size and the performance pattern of FC, adding up to enhance members' economic and social position.

  • PDF