• Title/Summary/Keyword: Ratio Valve

Search Result 570, Processing Time 0.029 seconds

Spin Valve Effect in Lateral Py/Au/Py Devices

  • Ku, Jang-Hae;Chang, Joon-Yeon;Koo, Hyun-Cheol;Eom, Jong-Hwa;Han, Suk-Hee;Kim, Gyu-Tae
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.152-155
    • /
    • 2007
  • Spin dependent transport was investigated in lateral $Py(Ni_{81}Fe_{19})/Au/Py$ spin valve devices. Clear spin valve effect was observed in conventional four-terminal measurement geometry. Higher resistance was found in antiparallel magnetization field of two Py electrodes which is determined by anisotropy magnetoresistance (AMR) measurements. The rectangular shape of spin signal together with good agreement of switching field convinces observed spin valve signal is resulted from effective spin injection and detection. The magnetoresistance ratio decays exponentially with channel length by which spin diffusion length of Au channel was estimated to be 76 nm.

Performance Analysis of Variable Valve for Diesel Engine with Cam-in-Cam System (디젤엔진용 Cam-in-Cam시스템 적용 가변밸브 성능해석)

  • Jeong, S.C.;Park, J.M.;Kim, T.K.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.22 no.1
    • /
    • pp.22-28
    • /
    • 2017
  • In this study, the effects of intake valve closing timing by using Cam-in-Cam system on combustion and emission characteristics for diesel engine were investigated under GT-POWER simulation environment. As a result, it was found that volumetric efficiency and effective compression ratio were decreased as the intake valve closing(IVC) timing is retarded due to its backflow effect. Also, we found that in-cylinder pressure, heat release rate and NOx emission were decreased as IVC timing was retarded. These show that the LIVC(late intake valve closing) can be effective to control AFR and mixing rate in diffusion combustion of diesel engine.

Trends in Heart Valve Surgery in Korea: A Report from the Heart Valve Surgery Registry Database

  • Choi, Jae Woong;Kim, Joon Bum;Jung, Yoo Jin;Hwang, Ho Young;Kim, Kyung Hwan;Yoo, Jae Suk;Lee, Sak;Lee, Seung Hyun;Sung, Kiick;Je, Hyung Gon;Lim, Mi Hee;Chang, Byung-Chul;Hong, Soon Chang;Lee, Heemoon;Shin, Yoon Cheol;Kim, Jae Hyun;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.388-396
    • /
    • 2022
  • Background: In this study, we present recent trends in heart valve surgery in Korea through analyses of data from the Korea Heart Valve Surgery Registry (KHVSR). Methods: We enrolled 8,981 patients who were registered in the KHVSR from 2017 to 2020. Yearly trends in patients' baseline characteristics, surgical profiles, and early mortality rates were explored. The observed/expected mortality ratio (O/E ratio), calculated from the actual mortality in the KHVSR and the predicted mortality estimated using the EuroSCORE II, was also analyzed. Results: The proportion of aortic valve surgery significantly increased from 56.8% in 2017 to 60.3% in 2020. The proportion of all combined procedures and minimally invasive surgery significantly increased over the 4-year study period. The operative mortality rate was 2.9% in the entire cohort, while mitral valve repair showed the lowest mortality risk (0.9%). The mortality rates of isolated aortic valve replacement (AVR) significantly decreased from 2.1% in 2017 to 0.8% in 2020 (p=0.016). Overall, the O/E ratio was 0.784 (95% confidence interval [CI], 0.677-0.902) demonstrating significantly lower actual mortality risks than expected based on the EuroSCORE II. In particular, the O/E ratios were as low as 0.364 (95% CI, 0.208-0.591) for isolated AVR. Conclusion: The recent data from the KHVSR showed increasing trends for complex procedures and minimally invasive surgery in heart valve surgery in Korea, and demonstrated remarkably low risks of operative mortality.

A Study on Effect of the Intake Valve Timing and Injection Conditions on the PCCI Engine Performance (흡기밸브 닫힘 시기와 분사조건이 PCCI 엔진의 성능에 미치는 영향에 관한 연구)

  • Lee, Jae-Hyeon;Kim, Hyung-Min;Kim, Yung-Jin;Lee, Ki-Hyung
    • Journal of ILASS-Korea
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • As world attention has focused on global warming and air pollution, high efficiency diesel engines with low $CO_2$ emissions have become more attractive. Premixed diesel engines in particular have the potential to achieve the more homogeneous mixture in the cylinder which results in lower NOx and soot emission. Early studies have shown that the operation conditions such as the EGR, intake conditions, injection conditions and compression ratio are important to reduce emissions in a PCCI (Premixed Charge Compression Ignition) engine. In this study a modified cam was employed to reduce the effective compression ratio. While opening timing of the intake valve was fixed, closing timing of the intake valve was retarded $30^{\circ}$. Although Atkinson cycle with the retarded cam leads to a low in-cylinder pressure in the compression stroke, the engine work can still be increased by advanced injection timing. On that account, we investigated the effects of various injection parameters to reduce emission and fuel consumption; as a result, lower NOx emission levels and almost same levels of fuel consumption and PM compared with those of conventional diesel engine cam timing could be achieved with the LIVC system.

A Study on the Flow Characteristics and Engine Performance with Swirl Ratio Variance of Intake Port (흡기포트 선회비 변경에 따른 유동특성 및 엔진성능에 관한 연구)

  • Yoon, Jun-Kyu;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.899-905
    • /
    • 2000
  • The characteristics of air flow and engine performance with swirl ratio variance of intake port In a turbocharged DI diesel engine was studied in this paper. The intake port flow is important factor which have influence on the engine performance and exhaust emission because the properties in the injected fuel depend on the combustion characteristics. The swirl ratio for ports was modified by hand-working and measured by impulse swirl meter. For the effects on performance and emission, the brake torque and brake specific fuel consumption were measured by engine dynamometer and NOx, smoke were measured by gas analyzer and smoke meter. As a result of steady flow test, when the valve eccentricity ratio are closed to cylinder wall, the flow coefficient and swirl intensity are increased. And as the swirl ratio is increased, the mean flow coefficient is decreasing, whereas the gulf factor is increasing. Also, through engine test its can be expected to meet performance and emission by optimizing the main parameters; the swirl ratio of intake port, injection timing and compression ratio.

  • PDF

Characteristics of Tumble Flow in Cylinder of 4 Valve Gasoline Engine by Using Particle Tracking Method (입자 추적법을 이용한 4 밸브 가솔린 기관의 실린더 내 텀블 유동 특성)

  • Lee, Chang-sik;Chon, Mun-soo;Chung, Sung-hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1178-1184
    • /
    • 1999
  • The in-cylinder flow field of gasoline engine comprises unsteady compressible turbulent flows caused by the intake port, combustion chamber geometry and the change of the spatial shape. Thus the quantitative analysis of the in-cylinder bulk flow plays an important role in the improvement of engine performances and the reduction of exhaust emission. The influences of tumble intensifying valve (TIV) and swirl intensifying valve (SIV), and various intake-flow conditions are compared with the tumble ratio obtained by the measured results of the in-cylinder gas flow. In order to obtain the quantitative analysis of the in-cylinder gas flows of gasoline engine this investigation applied the particle tracking method to the analysis of gas flow characteristics. Various intake conditions such as tumble and swirl intensifying valve, the deactivated condition of one valve among two intake valves, and the other factors of gas flow are considered.

Study on Statistical Analysis of Measured Fluid Leakage Data and Estimation of the Leakage Rate for Power Plant Valve (발전용 밸브 유체누설 측정 데이터의 통계적 평가 및 누설량 예측 연구)

  • Lee, S.G.;Kim, D.W.;Kim, Y.S.;Park, J.H;Jeong, H.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2009
  • High temperature and pressure valves in power plant have been used for fluid flowing and leakage occurred owing to valve internal damage such as disc wear, crack and inserting of foreign objects etc. in these valves. Recently, multi-measuring technique applied both ultrasonic and acoustic method have been used for evaluation of valve internal leakage in order to raise measurement reliability. Therefore, we have performed various leakage tests using ultrasonic and acoustic measuring system and acquired leakage data for the various leakage conditions. In this study, we developed the estimation method of regression model through leakage data, and expectation method for valve opening ratio, which is directly proportion to leakage rate, using the established estimation model from the measured data, valve size and fluid pressure so as to enhance data reliability. As a result of this study, it was founded that expectation method of leakage rate by statistical analysis method is appropriate to valve leakage evaluation.

  • PDF

Fabrication and Characteristics of a Piezoelectric Valve for MEMS using a Multilayer Ceramic Actuator (적층형 세라믹 엑추에이터를 이용한 MEMS용 압전밸브의 제작 및 특성)

  • 정귀상;김재민;윤석진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.515-520
    • /
    • 2004
  • We report on the development of a Piezoelectric valvc that is designed to have a high reliability for fluid control systems, such as mass flow control, transportation and chemical analysis. The valve was fabricated using a MCA(multilayer ceramic actuator), which has a low consumption power, high resolution and accurate control. The fabricated valve is composed of MCA, a valve actuator die and an seat die. The design of the actuator dic was done by FEM(finite element method) modeling, respectively. And, the valve seat die with 6 trenches was made. and the actuator die, which possible to optimize control to MCA, was fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the scat/actuator die structure. PDMS(poly dimethylsiloxane) sealing pad was fabricated to minimize a leak-rate. It was also bonded to scat die and stainless steel package. The flow rate was 9.13 sccm at a supplied voltage of 100 V with a 50 % duty ratio and non-linearity was 2.24 % FS. From these results, the fabricated MCA valve is suitable for a variety of flow control equipments, a medical bio-system, semiconductor fabrication process, automobile and air transportation industry with low cost, batch recess and mass production.

A Study on the Frequency Response Signals of a Servo Valve (서보밸브의 주파수 응답 신호에 관한 연구)

  • Yun, Hongsik;Kim, SungDong
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • The flow signal or spool position signal is used to determine the dynamic characteristics of directional control valves. Alternatively, the signal of spool position or flow can be replaced with the velocity of a low friction, low inertia actuator. In this study, the frequency response of the servo valve equipped with a spool position transducer is measured with a metering cylinder. The input signal, spool displacement, load pressure, and velocity of the metering cylinder are measured, and the theoretical results from the transfer function analysis are verified. The superposition rule for magnitude ratio and phase angle was found to be always applicable among any signal type, and it was found that the load pressure signal is not appropriate for use as the signal for measuring the frequency response of a servo valve. It was confirmed that the frequency response of a servo valve using metering cylinder was similar to the results from a spool displacement signal. The metering cylinder used for measuring the frequency response of a servo valve should be designed to have sufficiently greater bandwidth frequency than the bandwidth frequency of the servo valve.

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF