• 제목/요약/키워드: Ratio Test

검색결과 11,057건 처리시간 0.037초

Effect of measurement method and cracking on chloride transport in concrete

  • Zhang, Shiping;Dong, Xiang;Jiang, Jinyang
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.305-316
    • /
    • 2013
  • This paper aims to study the effect of measurement methods and cracking on chloride transport of concrete materials. Three kinds of measurement methods were carried out, including immersion test, rapid migration test and steady-state migration test. All of these measurements of chloride transport show that chloride ion diffusion coefficient decreased with the reduction of water to cement ratio. Results of the immersion test were less than that of rapid migration test and steady-state migration test. For the specimen of lower water to cement ratio, the external electrical field has little effect on chloride binding relatively. Compared with the results obtained by these different measurement methods, the lower water to cement ratio may cause smaller differences among these different methods. The external voltage can reduce chloride binding of concrete, and the higher electrical field made a strong impact on the chloride binding. Considering the effect of high voltage on the specimen, results indicate that results based on the steady-state migration test should be more reasonable. For cracked concrete, cracking can accelerate the chloride ion diffusion.

비부착 긴장재의 응력 변화에 영향을 미치는 변수에 관한 고찰 (Parametric study for influential factors on unbonded tendon stress increase)

  • 이선화;문정호;임재형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.651-656
    • /
    • 2000
  • The strain compatibility analysis shows that the influential parameters of loading type, reinforcing ratio, and span-depth ratio affect on the tendon stress in unbonded prestresses concrete member significantly. However, existing test results did not comply exactly with the analytical results. In consequence, the present study was planned to examine the parameters in order to complete Moon/Lim's design equation. The test variables with 12 specimens were loading type, reinforcing ratio, and span-depth ratio. As results, the effect of influential parameters were examined throughly and Moon/Lim's design equation was proven to be accurate.

  • PDF

섬유보강토의 전단특성에 관한 연구 (A Study on the Shear Charactersitics for Synthetics Fiber Reinformcements Soils)

  • 송창섭;임성윤;이용범
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.582-587
    • /
    • 1999
  • This study has been done to investigate the characteristics of synthetic fiber reinforcement sol with fully satruated . To this end, consolidated undrained triaxial test was performed on synthetic fiber reinforcement soil using the soft clay and plypropylene fiber . From the results of test, it was formed that the mixing ratio for weight and the aspect ratio of synthetic fiber have an effect on the shear characteristic of synthetic fiber rinforcement soil. Especially shear paramter C has line relationship for mixing ratio of fiber, and øhas parabolic relationship for mixing ratio of fiber.

  • PDF

제2수지-제4수지 길이 비율과 기질 및 성격 특성간의 상관관계 (The Correlation between $2^{nd}$ to $4^{th}$ Digit Length Ratio and Characteristics of Temperament and Character in University Students)

  • 전상원;김석현;오동훈;이유상;이선혜
    • 생물정신의학
    • /
    • 제17권3호
    • /
    • pp.136-144
    • /
    • 2010
  • Objectives : The $2^{nd}$ to $4^{th}$ digit length(2D : 4D) ratio reflects the amount of exposure and sensitivity to the prenatal sex hormone and it is considered to be the most convenient and useful way to understand the influence of sex hormone in the determination of human behavioral traits. This study was carried out to find the correlation between the 2D : 4D ratio and characteristics of temperament and character in Korean university students. We assumed that 2D : 4D ratio would show a strong correlation with temperament which is defined to be an inclination of an automatical emotional response to a stimulus. Methods : Participants were 104 university students who completed 2 self-report measures : Temperament and Character Inventory(TCI), Temperament Test. We examined the 2D : 4D ratio of each subject by measuring the lengths of the $2^{nd}$ and $4^{th}$ fingers using a photocopy measurement. We performed statistical analyses using correlation test and t-test to examine the relationship between 2D : 4D ratio and psychological characteristics. Results : We found out the typical sex difference in 2D : 4D ratio. Women had significantly higher 2D : 4D ratio than men. TCI-Character factor(TCI-C) didn't show any significant correlation with the 2D : 4D ratio. TCI-Tempterament factor(TCI-T) and the item of Temperament Test showed a significant correlation with the 2D : 4D ratio. In correlation analysis of the total group including all women and men, the 2D : 4D ratio showed a significant positive correlation in a subscale(shyness with stranger) of harm avoidance scales in TCI-T. In correlation analysis of women's group, the 2D : 4D ratio showed a significant positive correlation in two subscales( fear of uncertainty) and[shyness to stranger] of harm avoidance scales in TCI-T. In correlation analysis of men's group, the 2D : 4D ratio showed a significant negative correlation with a sanguine temperament item of the Temperament Test. Conclusion : The results suggest that the amount of exposure to sex hormone in the prenatal period seems to have an impact on the determination of temperament and characteristics.

결합재 타입 및 구성비 변화에 따른 시멘트 페이스트의 레올로지 특성 분석 (Analysis of Rheological Properties of Cement Paste with Binder Type and Composition Ratio)

  • 전성일;남정희;이문섭;노재면
    • 한국도로학회논문집
    • /
    • 제19권5호
    • /
    • pp.77-88
    • /
    • 2017
  • PURPOSES : It is necessary to clarify the rheological properties of cement paste as a basic research in the development of mechanistic concrete mix design. The rheological properties of cement paste with different binder types, mix propositions, and with/without high range water reducers have been analyzed. METHODS : In this study, ordinary Portland cement, fly-ash, blast furnace slag, silica fume, and limestone powder were used as binders. The range of water-binder ratio was 0.3-0.5, and a total of 30 different mixes have been tested. The slump flow test, V-funnel test, and Dynamic Shear Rheometer (DSR) test were performed to analyze the rheological properties of cement paste. RESULTS : As a result of the slump flow test, it was found that the composition ratio of the binder contents greatly affected the paste flow when the high range water reducers were added. The results of V-funnel test showed that when the water-binder ratio was decreased without high range water reducers, the binder composition ratio had a large effect on the passing time of the V-funnel tester, but with high range water reducers the impact of the binder composition ratio was decreased. The slump flow and V-funnel have a certain relationship with the rheological factors (yield stress and plastic viscosity), but the correlation was not significant. Finally, we proposed the M-value considering the density and specific surface area of the binder. The correlation between rheological factors and M-value were better demonstrated than experimental values, but there is still a limit to predict the rheological factor in general mix design. CONCLUSIONS :In this study, the rheological properties of cement paste were analyzed. The binder type, composition ratio of binder, and with/without high range water reducers have combined to provide the complex effects on the rheological properties of cement paste. The correlation between the proposed M-value and rheological factor was found to be better than experimental results, but needs to be improved in the future.

CRS시험에 의한 2차압밀계수의 결정방법 제안 (A New Proposed Technique for a Secondary Consolidation Coefficient Based on the Constant Rate of Strain Test)

  • 김형주;이민선;이용주;김대우
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.113-121
    • /
    • 2004
  • 본 연구는 사전압밀재하공법에 의해 연약지반을 개량시 재하-제하-재재하와 같은 다양한 응력변화에 의한 2차압밀량을 추정하고자, 일정변형률 압밀시험기(CRS)를 응용한 일정재하시험장치(CLR)와 표준압밀시험기를 이용한 단계 재하시험(IL)에 의해 군산점토의 압밀특성을 비교 고찰하였다. 또한 CRS시험 후 임의 팽창시점에서 재재하시 유효과압밀비에 따른 2차압밀특성과 간극비-유효응력-시간관계 등을 파악하였다. 군산점토는 유효 과압밀비가 클수록 팽창량은 크고 2차압밀 침하량은 작게 발생하고 있으며, 일시에 하중 제거 후, 재하하는 경우에서 2차압밀계수 $C'_{\alpha}$ 는 완속제거시 보다 작게 평가되고, 유효 과압밀비가 1.4이상인 경우는 유사한 값을 제시하고 있다. 재재하시 발생되는 전체침하량을 기준으로 한 2차압밀계수 $C"_{\alpha}$는 경과시간에 따라 비선형적으로 증가하나 최종값은 급속제거시와 비교하여 유사한 값을 제시하고 있다. 간극비 변형속도는 재하시간이 증가할수록 유효 과압밀비에 관계없이 2개의 시험 모두 일정한 선형관계이고, 유효 과압밀비가 증가할수록 작게 나타나고 있다.고 있다.

감마 일반화 선형 모형에서의 가능도비 검정과 F-검정 비교연구 (Comparing the performance of likelihood ratio test and F-test for gamma generalized linear models)

  • 조성일;한정섭;이우주
    • 응용통계연구
    • /
    • 제31권4호
    • /
    • pp.475-484
    • /
    • 2018
  • 감마 일반화 선형모형은 음이 아니며 치우침이 있는 반응변수에 유용한 모형으로 알려져 있다. 그러나 포아송 분포 또는 이항 분포에 기반한 일반화 선형모형에 비해 적은 관심을 받아왔다. 특히, 회귀계수의 유의성 검정에 대해서는 연구가 면밀히 되어 있지 않다. 본 논문에서는 감마 일반화 선형 모형의 검정에 대해 다양한 통계량들을 알아보고 수치 연구를 통해 그들의 성능을 비교한다. 수치 실험의 결과 부분 이탈도 검정 방법의 문제점이 나타났으며, 가능도비 검정 방법과 F-검정 방법이 좋은 성능을 보임을 확인하였다.

수동적 요추 신전 검사와 엎드린 상태에서 요추 불안정성 검사의 신뢰도와 타당도 (The Reliability and Validity of the Passive Lumbar Extension Test and the Prone Instability Test)

  • 사재민;김선엽
    • 한국전문물리치료학회지
    • /
    • 제18권3호
    • /
    • pp.85-93
    • /
    • 2011
  • The purpose of this study was to establish the reliability and validity of the passive lumbar extension (PLE) test and prone instability test (PIT). Thirty-three subjects (14 males, 19 females) with lower back pain enrolled in the study and the subjects were divided into 2 groups (positive and negative instability groups) on the basis of radiographies of flexion and extension. Reliability was determined by the kappa coefficient and validity was examined using calculated sensitivity, specificity, and the likelihood ratio. The results showed that the reliability of the PLE test was higher than the PIT (intra-rater reliability: k=.86 and k=.81, interrater reliability: k=.65 and k=.62) and the validity of the PLE test was also higher than the PIT (sensitivity: 91% and 62%, specificity: 95% and 85% positive likelihood ratio: 20.00 and 4.10, negative likelihood ratio: .10 and .45). In conclusion, we think that the PLE test was a more reliable and valid method for lumbar instability than the PIT.

공기 다단공급식 미분탄 버너의 NOx 저감 특성 (NOx Reduction Characteristics of Air Staging Burner for Pulverized-coal Combustion)

  • 박주식;김성완;최상일
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.153-160
    • /
    • 2001
  • The combustion test used DTF was performed to obtain the characteristics of NOx emission and reduction. In this test, major factor of NOx emission was a stoichiometric air ratio. At the onset of combustion to be rich oxygen, NOx was produced rapidly. Optimum condition for NOx reduction was formed under about AR:0.7 in the combustion test of Alaska coal. Investigations were undertaken with 200KW(th) test combustor. In combustion test, the major variables were coal feed ratio of center/outer, stoichiometric air ratio at the onset of combustion. The lowest NOx emission, 182ppm(6% O2 base), was achieved at about AR:0.6 of the first combustion stage with low NOx burner. Also, unburned carbon content of char collected in this combustion condition was about 1wt%.

  • PDF

분말형 폴리머를 사용한 시멘트 경화체의 내구성 평가 (Evaluation of Durability Properties of Cement Matrix Using the Polymer of Powder Type)

  • 김성수;정호섭;이정배;윤하영;고준호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.495-498
    • /
    • 2005
  • It was investigated the durability of the concrete to improve construction materials with polymer cement mortar in this study. With the popularity of repair and rehabilitation material, some mixtures composed of Ethylene Vinyl Acetate(EVA) was studied. Ethylene Vinyl Acetate(EVA) carried out tests to determine its properties which a include: freezing-thawing resistance test, carbonation test, and chemical resistance test. Result of freezing-thawing resistance test, mass change ratio and chemical resistance test, mass change ratio decreased of 12 and $15\~45\%$ as compared with control mortar. Carbonation depth decreased $3.7\~5.6mm$ as polymer-cement ratio increased $1\~4\%$.

  • PDF