• Title/Summary/Keyword: Raters

Search Result 169, Processing Time 0.024 seconds

Analysis of the Ability of Open Inquiry Performance for Pre-service Elementary Teachers (초등 예비 교사들의 자유 탐구 수행 능력 분석)

  • Hwang, Hyun-Jung;Jhun, Young-Seok
    • Journal of Korean Elementary Science Education
    • /
    • v.28 no.4
    • /
    • pp.404-414
    • /
    • 2009
  • The revised curriculum in 2007 includes open inquiry approach to increase students' interest in science and to build up creativity. So teachers and pre-service teachers should be equipped with the ability of open inquiry performance. In order to investigate pre-service teachers' readiness to perform open inquiry tasks, we analyzed reports written as homework by a group of 71 juniors in a national university of education. The investigation tool was composed of four domains: topic selection, the inquiry process, the conclusion, and reporting. Each domain had three or four sub-domains. By using the framework, four raters scored the students' inquiry reports. The findings reveal that the pre-service elementary school teachers have difficulty in the domain of 'topic selection' and the 'conclusion' compared with the other domains. Under the topic selection domain, they showed weaknesses in 'creativity' and 'scientific topic' and under the conclusion domain, they had difficulty in 'recognizing limits' and 'value of conclusion'. The finding suggests that pre-service teaching program should provide with opportunities to perform open inquiry continually.

  • PDF

A Study of Acoustic Measurement in Connected Speech with Dysphonia (음성장애 연속구어의 음향학적 분석)

  • Lee, Myoung-Soon
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.109-115
    • /
    • 2011
  • The purposes of this study were to identify acoustic parameters of connected speech and to contribute to acoustic analysis of dysphonic voice about patient's natural speech voice as well as sustained phonation of vowels. Acoustic parameters of sentences included LTAS (long-term average spectrum) mean and spectral slope over frequence ranges such as 0-4kHz, 0-6kHz, 0-8kHz, 0-12.5kHz as well as HNR. Acoustic parameters of the vowel 'a' included jitter, RAP, shimmer, NHR, and HNR. Based on 'G' of GRBAS for the severity of dysphonia, two experienced raters judged and classified as four groups including controls, mild, moderate and severe dysphonic group. Connected speech was two sentences extracted from 'stroll' passage. Parameters of the vowel and LTAS mean of the sentences were measured by CSL. The spectral slope of the sentences and HNR of the vowel and the sentences were measured by Praat. Data were statistically analyzed by Spearman correlation and Kruskal-Wallis test using SPSS 12.0. The results of this study are as follows: First, jitter, RAP, shimmer and NHR were significantly different between the groups. Second, for several frequencies, LTAS mean and spectral slope of the sentences were significantly different between the groups. Third, the HNR of the sentences were significantly different between the groups. Forth, there was a presence of correlation between HNR and NHR of the vowel and HNR of the sentences. Accordingly, this study concluded that LTAS, spectral slope, and HNR were predictive parameters of connected speech voice for dysphonic voice.

  • PDF

The Pilot study of Clock Drawing Test as a screening test for dementia (치매선별검사로서의 시계 그리기 검사(CDT)에 관한 기초연구)

  • Kim Gwang-Ho;Lim Jae-Hwan;Kim Jong-Woo;Whang Wei-Wan;Cho Seung-Hun
    • Journal of Oriental Neuropsychiatry
    • /
    • v.12 no.2
    • /
    • pp.185-191
    • /
    • 2001
  • Objectives: This study aimed to evaluate the usefulness as a screening test of Clock Drawing Test(CDT) compared with the standard K-DRS in probably dementia. Methods: The subjects for this study consisted of 19 elderly persons who visited to the outpatient department of Oriental Neuropsychiatry of the Kyunghee Oriental hospital. They received the K-DRS and the Clock Drawing Test. Three observers evaluated them with circle, numbers, hands. Inter-rater reliability of scores from Clock Drawing Test was assessed and Pearson correlation coefficients were used to examined the relationships between scores from Clock Drawing Test and K-DRS. Results: Correlations between individual raters was highly significant (r= .957, .974, and .970, respectively: p<.001). There was stastically significant correlations between K-DRS and CDT scores (r= 0.849, p<.001). Conclusions: The CDT can be rated reliably by observers and correlations between CDT and K-DRS is significantly high. We confirmed the usefulness of CDT as simple, easily administered, low cost, and reliable general screening test for dementia.

  • PDF

User Benefit Characteristics of Customized Housing Design Guideline for Childcare Families (사용자혜택 이론에 따른 신혼·육아가구 맞춤형 주택계획가이드 라인의 특성 연구)

  • Lee, Yeunsook;Ahn, Somi;Park, Jaehyun
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.5
    • /
    • pp.63-70
    • /
    • 2016
  • Modern society is suffering from the phenomena of low-fertile, ultra-aging, and low-growth. On this social flow, most social classes undergo vulnerable situation and their overall housing and living condition have difficulties. So far many housing guidelines for diverse population were developed, recently, inclusive 'Customized Housing Design Guideline for Childcare Families' in terms of maintaining family and society has been completed. The purpose of this study is to analyze User Benefit Characteristics of 'Customized Housing Design Guideline for Childcare Families'. The research subjects are essential 140 guidelines appropriate to children's development and parents' care. The research method is contents analysis and the analysis criterion are 4 concepts of the User Benefit Criteria- 'Behavioral Facilitation (BF)', 'Physiological Maintenance (PhM)', 'Perceptual Maintenance (PM)', 'Social Facilitation (SF)'. 3 people inter-raters reliability was established. Altogether, the guidelines were rated in the order of PhM>PM>BF>SF, and these characteristics are similar as common universal design guidelines. This showed the supportability of spatial characteristics in the guidelines related to user's special behaviors. Also, the results show the importance of outdoor space planning for safe social interactions. The supportable characteristics of 'Customized Housing Design Guideline for Childcare Families' could be expected to efficiently apply for new housing development in the future.

The Application of Circular Boundary Overlapping in 3-D Reconstruction of Neck Tumors (두경부 종물의 3차원 재건 영상에서, 원형 경계선 중첩을 이용한 경계선 추출법의 응용)

  • Yoo, Young-Sam
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.204-211
    • /
    • 2010
  • Background and Objectives : Boundary detection and drawing are essential in 3D reconstruction of neck mass. Manual tracing methods are popular for drawing head and neck tumor. To improve manual tracing, circular boundaries overlapping was tried. Materials and Methods : Twenty patients with neck tumors were recruited for study. Representative frames were examined for shapes of outline. They were all single closed curves. Circular boundaries were added to fill the outlines of the tumors. Inserted circles were merged to form single closed curves(Circular boundary overlapping, CBO). After surface rendering, 3 dimensional images with volumes and area data were made. Same procedures were performed with manual tracing from same cases. 3D images were compared with surgical photographs of tumors for shape similarity by 2 doctors. All data were evaluated with Mann-Whitney test(p<0.05). Results : Shapes of boundaries from CBO were similar with boundaries from manual tracing. Tumor outlines could be filled with multiple circular boundaries., While both boundary tracing gave same results in small tumors, the bigger tumors showed different data. Two raters gave the similar high scores for both manual and CBO methods. Conclusion : Circular boundary overlapping is time saver in 3 dimensional reconstruction of CT images.

User Reputation computation Method Based on Implicit Ratings on Social Media

  • Bok, Kyoungsoo;Yun, Jinkyung;Kim, Yeonwoo;Lim, Jongtae;Yoo, Jaesoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1570-1594
    • /
    • 2017
  • Social network services have recently changed from environments for simply building connections among users to open platforms for generating and sharing various forms of information. Existing user reputation computation methods are inadequate for determining the trust in users on social media where explicit ratings are rare, because they determine the trust in users based on user profile, explicit relations, and explicit ratings. To solve this limitation of previous research, we propose a user reputation computation method suitable for the social media environment by incorporating implicit as well as explicit ratings. Reliable user reputation is estimated by identifying malicious information raters, modifying explicit ratings, and applying them to user reputation scores. The proposed method incorporates implicit ratings into user reputation estimation by differentiating positive and negative implicit ratings. Moreover, the method generates user reputation scores for individual categories to determine a given user's expertise, and incorporates the number of users who participated in rating to determine a given user's influence. This allows reputation scores to be generated also for users who have received no explicit ratings, and, thereby, is more suitable for social media. In addition, based on the user reputation scores, malicious information providers can be identified.

A comparison of CPP analysis among breathiness ranks (기식 등급에 따른 CPP (Cepstral Peak Prominence) 분석 비교)

  • Kang, Youngae;Koo, Bonseok;Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.21-26
    • /
    • 2015
  • The aim of this study is to synthesize pathological breathy voice and to make a cepstral peak prominence (CPP) table following breathiness ranks by cepstral analysis to supplement reliability of the perceptual auditory judgment task. KlattGrid synthesizer included in Praat was used. Synthesis parameters consist of two groups, i.e., constants and variables. Constant parameters are pitch, amplitude, flutter, open phase, oral formant and bandwidth. Variable parameters are breathiness (BR), aspiration amplitude (AH), and spectral tilt (TL). Five hundred sixty samples of synthetic breathy vowel /a/ for male were created. Three raters participated in ranking of the breathiness. 217 were proved to be inadequate samples from perceptual judgment and cepstral analysis. Finally, 343 samples were selected. These CPP values and other related parameters from cepstral analysis are classified under four breathiness ranks (B0~B3). The mean and standard deviation of CPP is $16.10{\pm}1.15$ dB(B0), $13.68{\pm}1.34$ dB(B1), $10.97{\pm}1.41$ dB(B2), and $3.03{\pm}4.07$ dB(B3). The value of CPP decreases toward the severe group of breathiness because there is a lot of noise and a small quantity of harmonics.

Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments (주관절 가동범위 측정법에 대한 동시타당도와 신뢰도)

  • Current, Marion E.;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

Reliability of Visual Gait Analysis according to Clinical Experience Level of Physical Therapists (임상 물리치료사의 경험에 따른 시각적 보행 분석의 신뢰도 연구)

  • Lee, In-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.174-179
    • /
    • 2013
  • Purpose: Visual gait analysis plays a pivotal role in determining the important gait problem of patients. A few studies have been published and have received little attention regarding visual gait analysis on patients with orthopedic problems. The purposes of this study were to investigate the difference of reliability levels according to experience of clinical physical therapists. Methods: Thirty-five clinical physical therapists, 5 high experienced, 15 experienced, and 15 inexperienced, were recruited and individually evaluated these videotaped gait patterns of the participants, and filled up the structured gait analysis form. The gait of nine participants was videotaped. Reliability levels were calculated by the Intraclass Correlation Coefficients (ICC). Results: The inter-rater reliability of high experienced group (ICC=0.56; 95% CI: 0.50-0.62) was comparable to that of the experienced raters (ICC=0.48; 95% CI: 0.43-0.53) and inexperienced group (ICC=0.42; 95% CI: 0.38-0.46). High experienced group reached a higher inter-rater reliability level. The average intra-rater reliability of the high experienced group was 0.70 (ICCs ranging from 0.54 to 0.82). The experienced group reached an average intra-rater reliability of 0.61 (ICCs ranging from 0.47 to 0.81). The inexperienced group attained average ICC values of 0.53 (ICCs ranging from 0.30 to 0.74). Conclusion: Use of a structured gait analysis form as described in this study was found to be moderately reliable. Clinical experience appears to increase the reliability of visual gait analysis.