• 제목/요약/키워드: Rate of power consumption

검색결과 874건 처리시간 0.028초

플라스틱 연료탱크 생산 설비에서의 소비 전력 저감을 위한 공조 시스템 설계 및 경제성 평가 (Design and Economics of HVAC System for Reduction of Power Consumption in Blow Mold Machine)

  • 이영재;최석천
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.84-93
    • /
    • 2017
  • This study was carried out to improve the electric power consumption of HVAC in the blow mold machine(BMM) and work environment. The experiment was conducted with the simulated HVAC system of 1/15 of the actual BMM. The temperature of main facility and two preheaters was fixed at 200 and $60^{\circ}C$ respectively in all test conditions. The measured points of temperature were chosen as critical locations considering the work environment. The tendency of temperature distributions decreases as the duct was closed to the main facility. The reduction rate of power consumption of HVAC increases up to 32.3% when both duct and cooling systems are operated. Also the efficiency of HVAC is improved about 9% through the modified design of duct system. It notes that the electric power consumption of HVAC can be reduced by the optimum design and operating condition of duct and cooling system.

섬유기반 녹화시스템 적용에 따른 노후주택의 누진세기반 전력요금 저감효과에 대한 모니터링 연구 (A Study on Monitoring the Progressive Tax-based Power Charges Reduction Effects by Applying Fiber-based Artificial Vegetation System to Obsolete Houses)

  • 김태한;이소담
    • 한국환경복원기술학회지
    • /
    • 제20권6호
    • /
    • pp.67-77
    • /
    • 2017
  • Demands for housing has diversified recently due to low birth rate and the growth of aging population. Also, a share of idle houses and obsolete houses over 20 years old is gradually rising. Therefore, there is a need for a sustainable, environment-friendly improvement policy that is in line with a new housing paradigm and avoids full-scale new construction, such as a customized housing renovation plan considering local economic circumstances. Therefore, afforestation system applicable to buildings are assessed positively, but lack objective performance evaluation. Through one-year, long-term monitoring of replicated obsolete buildings that have poor insulation performance, this study calculated monthly average power consumption and analyzed power charges by applying pricing plans before and after the revision of progressive tax in order to examine economic effects expected by applying the afforestation system. In the obsolete buildings, the study showed that monthly average power consumption was reduced by 16.6kWh with 5.2% average reduction rate. Highest reduction was made in July at 11.3%. Aggregate monthly power consumption charges were relatively high in winter before and after the revision of progressive tax. Power charges reduction effect was highest in March when monthly power consumption was reduced to 300kWh level by applying the afforestation system.

심층신경망을 활용한 도심용 무인항공기의 전력소모 예측 모델링 및 분석 (Power Consumption Modeling and Analysis of Urban Unmanned Aerial Vehicles Using Deep Neural Networ)

  • 김민지;백돈규
    • 한국산업정보학회논문지
    • /
    • 제28권1호
    • /
    • pp.17-25
    • /
    • 2023
  • 도심용 무인항공기의 사용범위가 넓어지면서 다양한 미션을 효율적으로 수행하기 위해서는 배터리를 합리적으로 운용해야 한다. 배터리를 합리적으로 운용하기 위해서는 실제 비행 미션을 수행하기 전에 다양한 시뮬레이션을 통해 최적의 경로를 도출할 수 있다. 이를 위해서는 배터리의 전력 소모 및 에너지 잔량을 예측 하는 것이 중요하다. 본 논문에서는 도심용 무인항공기의 비행 중 속도 및 가속도에 따른 소비전력 간의 관계성을 분석하고 이를 이용해 빠르게 소비전력을 도출 할 수 있는 선형 전력 소모 모델을 도출하였다. 또한, 정확한 전력 소모를 예측하기 위해서 딥러닝에 기반한 전력 소모 모델을 도출하였다. 이때 정확하며 효율적인 전력소모 모델을 얻기 위해 모델링 입력 값으로 1) GPS 3축 속도 및 가속도, 2) IMU 3축 속도, 3) IMU 3축 속도 및 가속도 데이터를 사용한 모델들을 도출하여 비교하였다. 최종적으로 얻은 모델은 전력소모 오차율 5.86%을 얻었으며, 누적 에너지 오차율 1.50%를 얻었다.

동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구 (A study on energy efficiency improvement of waste-water treatment system by freeze concentration method)

  • 김정식;임승택;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.467-476
    • /
    • 2013
  • 동결농축법은 열역학적 효율이 높고 에너지 소비량이 작으며 처리수를 재활용할 수 있는 장점을 가지고 있다. 본 연구에서는 중소규모로 상용화 가능한 동결농축폐수처리시스템을 설계하고, 각 시스템의 에너지 소비효율과 일일처리량을 비교하여 시스템 개발방향을 제안하고자 하였다. 시스템을 완속운전시스템과 급속운전시스템으로 각각 모델링하고 해석을 통해 소비동력과 운전시간을 계산하여 비교한 다음 설계처리량에 따른 변화를 추가 검토하였다. 연구결과 급속운전시스템의 소비전력량비가 0.6 Wh/kg 만큼 다소 높으나 일일처리량은 19 % 증가하였으며, 설계처리량이 큰 시스템일수록 소비전력량비가 작아지고 일일처리량이 큰 결과를 얻었다.

Low-Swing 기술을 이용한 저 전력 병렬 곱셈기 설계 (Design of a Low-Power Parallel Multiplier Using Low-Swing Technique)

  • 강장희;김정범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.79-82
    • /
    • 2003
  • This paper describes a new low-swing inverter for low power consumption. To reduce a power consumption, an output voltage swing is in the range from 0 to $V_{ref}-V_{TH}$, where $V_{ref}=V_{DD}-nV_{TH}$. This can be done by the inverter structure that allow a full swing or a swing on its input terminal without leakage current. Using this low-swing voltage technology, we propose a low-power $4\times4$ bit parallel multiplier. The proposed circuits are simulated with HSPICE under $0.35{\mu}m$ CMOS standard technology. Compare to the previous works, this circuit can reduce the power consumption rate of 11.2% and the power-delay product of 10.3%.

  • PDF

공공하수처리시설에서 에너지 사용현황 및 절감방안 연구 (A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant)

  • 김종락;이가희;유광태;김동윤;이호식
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

저전력 무선 센서네트워크를 위한 비터비 알고리즘의 적용 및 분석 (Analysis of Viterbi Algorithm for Low-power Wireless Sensor Network)

  • 박우준;김건욱
    • 대한전자공학회논문지TC
    • /
    • 제44권6호
    • /
    • pp.1-8
    • /
    • 2007
  • 한정된 배터리 전원을 사용하는 무선 센서 네트워크에서 노드의 수명유지를 위해 전력 소모량은 매우 중요한 문제이다. 전력소모를 줄이기 위해 저전력 RF 통신을 사용함으로써 무선 센서 네트워크의 에러 발생률이 증가하게 된다. 본 논문에서는 무선 센서 네트워크의 오류 정정 부호 사용과 그에 따른 전력 소모량을 분석하였다. 오류 정정 부호는 변 복조 과정에서 소모되는 저려 소모가 있지만, 부호화 이득을 통해 전송 에너지를 절약할 수 있다. 센서 노드의 특성상 전송 에너지는 프로세서의 계사에 소모되는 에너지보다 큰 비중을 차지하고 있다. 본 논문에서는 낮은 전송 전력으로 전송한 데이터를 짧은 구속장의 Viterbi 알고리즘을 적용하여 오류 정정을 할 경우 단순한 ARQ(Auto Repeat Request) 방식을 사용할 경우보다 최대 20%의 재전송 횟수의 감소와 18%의 전력 소모의 감소를 분석하였다.

8-bit 10-MHz CMOS A/D 변환기 (A 8-bit 10-MHz CMOS A/D Converter)

  • 박창선;손주호;이준호;김종민;김동용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.263-266
    • /
    • 1999
  • In this work, a A/D converter is implemented to obtain 8bit resolution at a conversion rate of 10MS/s for video applications. This architecture is proposed using the Pipelined architecture for high speed conversion rate and the Successive - Approximation architecture for low power consumption, and consists of two identical stages that consist of sample/hold circuit, low power comparator, voltage reference circuit and MDAC of binary weighted capacitor array. Proposed A/D converter is designed using 0.25${\mu}{\textrm}{m}$ CMOS technology The SNR is 80㏈ at a sampling rate of 10MHz with 1.95MHz sine input signal. When an 8bit 10MS/s A/D converter is simulated, the Differential Nonlinearity / Integral Nonlinearity (DNL/ INL) error are $\pm$0.5 / $\pm$2 LSB, respectively. The power consumption is 13㎽ at 10MS/s.

  • PDF

전력선통신 시스템을 위한 딥 러닝 기반 전력량 예측 기법 (Power Consumption Prediction Scheme Based on Deep Learning for Powerline Communication Systems)

  • 이동구;김수현;정호철;선영규;심이삭;황유민;김진영
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.822-828
    • /
    • 2018
  • 최근 전력 사용량의 증가로 인한 대규모 블랙아웃 등 에너지 문제가 대두되고 있으며, 이 문제들로 인해 전력 소비량 예측에 대한 정확도를 개선할 필요성이 부각되었다. 본 연구에서는 딥 러닝 기반의 전력 사용량 예측 실험을 통해서 실제 전력 소비량과 예측된 전력 소비량의 차이를 계산하고, 이를 통해서 전력 예비율을 기존 대비 하향 조정할 수 있는 가능성에 대해서 살펴본다. 예비 전력은 사용하지 않으면 손실되는 전력으로, 본 논문에서의 딥 러닝 기반 전력 소비량 예측을 통해서 여분의 전력을 과도하게 생산하지 않도록 오차범위 내에서 전력 예비율을 감소시킬 수 있는 기반을 마련할 수 있다. 본 논문에서 사용하는 딥 러닝 기법은 시계열 데이터를 처리하는 Long-Short-Term-Memory(LSTM) 구조의 학습 모델을 이용한다. 컴퓨터 시뮬레이션에서는 임의 생성한 전력 소비 데이터를 토대로 모델을 학습시키고, 학습된 모델을 토대로 전력 사용 예측값을 구하고 실제 전력 소비량 간에 오차를 계산한 결과 오차율 21.37%를 얻을 수 있었다. 이는 최근의 전력 예비율 45.9%를 고려할 때, 본 연구에서 제안한 전력 소비량 예측 알고리즘을 적용하는 경우 20% 포인트 정도의 예비율 감축이 가능하다.

Performance Improvement and Power Consumption Reduction of an Embedded RISC Core

  • Jung, Hong-Kyun;Jin, Xianzhe;Ryoo, Kwang-Ki
    • Journal of information and communication convergence engineering
    • /
    • 제10권1호
    • /
    • pp.78-84
    • /
    • 2012
  • This paper presents a branch prediction algorithm and a 4-way set-associative cache for performance improvement of an embedded RISC core and a clock-gating algorithm with observability don’t care (ODC) operation to reduce the power consumption of the core. The branch prediction algorithm has a structure using a branch target buffer (BTB) and 4-way set associative cache that has a lower miss rate than a direct-mapped cache. Pseudo-least recently used (LRU) policy is used for reducing the number of LRU bits. The clock-gating algorithm reduces dynamic power consumption. As a result of estimation of the performance and the dynamic power, the performance of the OpenRISC core applied to the proposed architecture is improved about 29% and the dynamic power of the core with the Chartered 0.18 ${\mu}m$ technology library is reduced by 16%.