• Title/Summary/Keyword: Rate of change of frequency

Search Result 562, Processing Time 0.031 seconds

A Study on Dielectric Properties of PCW-PNN-PZT ceramics (PCW-PNN-PZT계 세라믹의 유전 특성에 관한 연구)

  • Shin, Hye-Gyeong;Lee, Sung-Ho;Jung, Bo-Ram;Bae, Seon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.51-53
    • /
    • 2005
  • This study was to measure the minuteness structure, dielectric properties of 0.03PCW-0.07PNN-0.9PZT ceramics according to sintering temperature manufacture the specimens with a general method. The results of this study were gotten such as follows. The crystal structure of ceramic changed the rombohedral structure into teteragonal structure according to rising sintering temperature in XRD. Dielectric constant at $20^{\circ}C$ showed its maximum value 510.599 in specimens sintered at $1100^{\circ}C$ and dielectric loss showed its minimum value 7.43% in specimens sintered at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of frequency showed its minimum value 0.029/kHz at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of temperature showed its minimum value $1.40/^{\circ}C$ at $1500^{\circ}C$.

  • PDF

A Study of Tool Breakage Dection Using AE Sensor (AE(acoustic emission)센서를 이용한 공구파손검출에 관한 연구)

  • Lee, Jae-Jong;Song, Jun-Yeop;Park, Hwa-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.61-68
    • /
    • 1989
  • As the system monitoring technology become required in order to improve the system performance and the productivity, we’ve studied to the detection for the tool wear and the tool breakage using AE sensors that is able to detection of generated high frequency stress pulse at cutting. The detection system is consist of a sensing part, a amplifier part, a signal processing part, and a analysis & output part. The moment (a rms and a kurtosis) of statistical method is used for analysis of AE singnal. The experiment are carried out in a CNC lathe. In this study, we achieved that the amplitude level of the AE signal and statistical moments was largely changed as the tool failure. The change rate of Kurtosis was especially large, but the change rate of the rms was small.

  • PDF

FPGA Implementation of BCH Encoder to change code rate (부호율 변경이 가능한 BCH Ecoder의 FPGA구현)

  • Jegal, Dong;Byon, Kun-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.485-488
    • /
    • 2009
  • The class of BCH codes is a large class of error correction codes. HDL implementation of BCH code generator to change code rate. and used System Generator, and implemented hardware to FPGA. Loaded bit stream to a FPGA board in order to verify this design to Hardware co-simulation from these results. Also, compared as investigated the maximum action frequency through timing analysis and resource of logic in order to evaluate performance of BCH code generator.

  • PDF

Spectral Analysis of Heart Rate Variability during Treadmill Exercise at Various Speeds and Grades

  • Kim, Hyeong-Jin;Kim, Ki-Hong;Ahn, Dong-Kuk;Park, Jae-Sik
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • This study was aimed to elucidate the changes in heart rate variability during treadmill exercise at various speeds and grades by spectral analysis. Thirty-three untrained male college students aged $20{\sim}26\;yr $were employed to exercise on a treadmill using 4 speeds (4.02, 5.47, 6.76 and 8.05 km/h) and 6 grades (0, 4, 8, 12, 16 and 20%). A fixed speed was selected for each session with the grade increased every 3 min. The electrocardiogram, respiration and the stepping activity were continuously recorded through an A/D converter system on the computer disk. Power spectra of heart rate variability (RRV) were obtained by use of a fast Fourier transform algorithm. The frequency domain was divided into 3 bands: $VLF\;(0{\sim}0.04\;Hz),\;LF\;(0.04 {\sim}0.15\;Hz)\;and\;HF\;(0.15{\sim}1.00\;Hz).$ Heart rate was $74.4{\pm}2.1\;beats/min$ at rest and showed a steady increase during treadmill exercise with increasing speed and grade up to $196.7{\pm}5.0\;beats/min.$ Total power of HRV was $35.0{\pm}6.7\;(beats/min)^{2}$ at rest and progressively decreased during exercise down to $1.9{\pm}0.3\;(beats/min)^{2}.$ The %VLF power of HRV was $34.5{\pm}3.7\; %$ at rest and showed no significant change during exercise except for a decrease observed at the highest intensity of exercise. The %LF power was $44.1{\pm}3.0\;%$ at rest and showed a progressive decrease down to $4.5{\pm}1.0\;%$ during those stages of exercise where heart rate was over 135 beats/min. The %HF power was $21.4{\pm}2.9\;%$ at rest and showed a progressive increase up to $87.1{\pm}6.7\;%$ during higher intensity exercise where heart rate was over 165 beats/min. Peak frequency of HF band was $0.200{\pm}0.018\;Hz$ at rest and was shifted to higher frequencies up to $0.909{\pm}0.048\;Hz$ at heart rates greater than 135 beats/min. Respiratory frequency was $18.0{\pm}1.5$ breaths/min at rest and significantly increased during exercise up to $53.0{\pm}3.7$ breaths/min. Stride frequency during treadmill exercise showed an increasing tendency with increasing speed from $55.6{\pm}0.9$ steps/min at 4.02 km/h to $81.2{\pm}0.6$ at 8.05 km/h. It was concluded that total power of HRV decreased progressively with increasing exercise intensity due to the withdrawal of parasympathetic activity. At higher exercise intensity, % LF power decreased and %HF power increased with its peak frequency shifted to higher values in a progressive mode with increasing speed and grade, reflecting a readjustment in the cardiovascular system and the increased respiration and its rate, respectively.

  • PDF

The Optimum Modification of Dynamic Characteristics of Stiffened Plate Structure Including the Number of Stiffener (보강재의 수를 포함한 보강판 구조물의 동특성의 최적변경)

  • 박성현;고재용
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.4
    • /
    • pp.461-469
    • /
    • 2001
  • The purpose of this paper is the optimum modification of dynamic characteristics of stiffened plate structure including the number of stiffener. This paper shows the optimum structural modification method by dynamic sensitivity analysis and quasi-least squares method and considers it's validity. In the method of the optimization, finite element method, sensitivity analysis and optimum structural modification method are used. The change of natural frequency and total weight are made to be an objective function. Thickness of plate, the number of stiffener and cross section moment of stiffener become a design variable. The dynamic characteristics of stiffened plate structure is analyzed using finite element method. Next, rate of change of dynamic characteristics by the change of design variable is calculated using the sensitivity analysis. Then, amount of change of design variable is calculated using optimum structural modification method. It is shown that the results are effective in the optimum modification for dynamic characteristics of the stiffened plate structure including the number of stiffener.

  • PDF

Study on the Optimum Modification and Modal Analysis of Stiffened Plate of Ship Hull Structure (신체의 Stiffened Plate 구조물의 모우드해석과 최적변경법에 관한 연구)

  • 박성현;박석주;고재용
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.10b
    • /
    • pp.51-58
    • /
    • 2000
  • The purpose of this study is the optimum modification of dynamic characteristics of stiffened plate structure. In the method of the optimization ,finite element method (FEM), sensitivity analysis and optimum structural modification method are used. To begin with, using FEM, the dynamic characteristics of stiffened plate structure is analyzed. Next, rate of change of dynamic characteristic by the change of design variable is calculated using the sensitivity analysis. Then, amount of change of design variable is calculated using this sensitivity value and optimum structural modification method. The change of natural frequency is made to be an objective function. Thickness of plate and cross section moment become a design variable. It is shown that the results are effective in the optimum modification for dynamic characteristics of the stiffened plate structure.

  • PDF

Cardiac Activation Associated with Non-Periodic Leg Movements in Comparison to Periodic Leg Movements during Sleep in Patients with Restless Legs Syndrome and Healthy Subjects

  • Kim, Min-Jong;Cha, Kwang Su;Kim, Tae-Joon;Jun, Jin-Sun;Jung, Ki-Young
    • Journal of Sleep Medicine
    • /
    • v.15 no.2
    • /
    • pp.68-73
    • /
    • 2018
  • Objectives: Periodic leg movements in sleep (PLMS) are associated with arousals and autonomic activation, which may contribute to higher cardiovascular disease risk in patients with restless legs syndrome (RLS). Non-periodic leg movements in sleep (NPLM) are leg jerks in sleep that does not satisfy standard criteria of PLMS. The aim of this study was to evaluate impact of short-interval leg movements in sleep (SILMS) and isolated leg movements in sleep (ILMS) in comparison to PLMS on heart rate in both patients with RLS and healthy controls. Methods: Seven idiopathic RLS patients and 9 controls were enrolled in this study. Polysomnographic studies were analyzed and leg movements (LM) were automatically detected. NPLM can be classified as SILMS and ILMS. SILMS are LM separated by an inter-movement interval (IMI) shorter than 10 s, and ILMS are LM with IMI longer than 90 s. Frequency and heart rate associated with SILMS, ILMS, and PLMS in RLS patients were compared to those in controls. Heart rate change associated with LM were determined for a fixed time window. Results: Frequencies of SILMS and ILMS of patients with RLS were not significantly different to those of controls. RLS patients presented higher heart rate change associated with SILMS than PLMS before movement onset, while heart rate change associated with SILMS, ILMS, and PLMS were not different in the controls. Conclusions: Although the number of SILMS is not higher than PLMS, SILMS may have closely associated with higher cardiac activation of RLS than PLMS. Therefore, SILMS might be an important treatment target for patients with RLS to reduce long-term cardiovascular risk. Long-term prospective studies are needed to evaluate the relationship between NPLM and cardiovascular disease in patients with RLS.

Analysis of Concept's Diversity and Proximity for Photosynthesis in Grade 7 Students

  • Lim, Soo-Min;Jeong, Jae-Hoon;Kim, Youngshin
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.6
    • /
    • pp.1050-1062
    • /
    • 2012
  • Concepts of science have been developed by occupying 'ecological niche' within conceptual ecology. The ecological niche is determined from the mutual effect between intellectual environmental of the learner and new concept, which few studies have been conducted. This study examined how the ecological niche of the concept of photosynthesis in $7^{th}$ grade is changed by instruction. The ecological niche was analyzed using 2 methods: (1) the change in the diversity of concepts, and (2) the change in the proximity of concepts based on the frequency and the relativeness score of the concepts. The concept of photosynthesis was analyzed in the 4 domains in the place of photosynthesis, products of photosynthesis, reactants of photosynthesis, and environmental factors. The results of this study are as follows: (1) reduced diversity of concepts, (2) increased frequency and relativeness score of the scientific concepts, and (3) increased proximity of the scientific concepts by instruction. With these results, the mutual effects of the concepts within the conceptual ecology have become active by class to differentiate the relationships between the concepts, which accordingly displayed their changes in status.

The Effect of Electrical Stimulation Applied in Dominant Forearm on Autonomic Nervous System Response of Both Hands (우세측 전완에 적용한 전기자극이 양쪽 손 자율신경계 반응에 미치는 효과)

  • Lee, Dong-Geol;Seo, Sam-Ki;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effect of electrical stimulation applied in dominant forearm on autonomic nervous system response of both hands. Methods : Fourteen healthy subjects (women) received low frequency-high intensity electrical stimulation to one forearm. The subjects assigned to two groups; a ipsilateral stimulation group (n=7) and a contralateral stimulation group (n=7). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was set as 15 minutes. Measuring items were the skin conduction velocity, the blood flow, and the pulse rate, which were measured total 3 times (pre, post, and post 10 min.). Results : The skin conduction velocity showed a significant difference according to the change of the time in both hands, but there was no significant difference according to time in the blood flow, and the change of the pulse frequency regardless of stimulus side. Conclusion : These results demonstrate that the low frequency-high intensity electrical stimulation applied dominant forearm can increase selectively only with the skin conduction velocity, which may be helpful for the activation of the sudomotor function of both hands by the activation of sympathetic nerve.

Characteristic Analysis of High Speed Inkjet Printing Head for Digital Textile Printing (디지털날염용 고속 구동형 잉크젯 프린팅 헤드의 특성해석)

  • Lee, Duck-Gyu;Hur, Shin
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.421-426
    • /
    • 2018
  • To develop a piezoelectric inkjet printhead for high-resolution and high-speed printing, we studied the characteristics of an inkjet printhead by analyzing the major design parameters. An analytical model for the inkjet printhead was established, and numerical analysis of the coupled first-order differential equation for the defined state variables was performed using state equations. To design the dimension of the inkjet printhead with a driving frequency of 100 kHz, the characteristics of the flow rate and discharge pressure of the nozzle were analyzed with respect to design variables of the flow chamber, effective sound wave velocity, driving voltage, and voltage waveform. It was predicted that the change in the height of the flow chamber does not significantly affect the Helmholtz resonance frequency and discharge speed of the nozzle. From the analysis of change in flow chamber width, it is observed that as the width of the flow chamber increases, the ejection speed greatly increases and the Helmholtz resonance frequency decreases considerably, thereby substantially affecting the performance of the inkjet printhead.