• Title/Summary/Keyword: Rate of change of frequency

Search Result 553, Processing Time 0.032 seconds

The Characteristics and Improvement Directions of Regional Climate Change Adaptation Policies in accordance with Damage Cases (지자체 기후변화 적응 대책 특성 및 개선 방향)

  • Ahn, Yoonjung;Kang, Youngeun;Park, Chang Sug;Kim, Ho Gul
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.296-306
    • /
    • 2016
  • There is a growing interest in establishing a regional climate change adaptation policy as the climate change impact in the region and local scale increases. This study focused on the analysis of 32 regions on its characteristics of local climate change adaptation plans. First, statistic program R was used for conducting cluster analysis based on the frequency and budgets of adaptation plan. Further, we analyzed damage frequency from newspapers regarding climate change impacts in eight categories which were caused by extreme weather events on 2,565 cases for 24 years. Lastly, the characteristics of climate change adaptation plan was compared with damage frequency patterns for evaluating the adequacy of climate change adaptation plan on each cluster. Four different clusters were created by cluster analysis. Most clusters clearly have their own characteristics on certain sectors. There was a high frequency of damage in 'disaster' and 'health' sectors. Climate change adaptation plan and budget also invested a lot on those sectors. However, when comparing the relative rate among regional governments, there was a difference between types of damage and climate change adaptation plan. We assumed that the difference could come from that each region established their adaptation plans based on not only the frequency of damage, but vulnerability assessment, and expert opinions as well. The result of study could contribute to policy making of climate change adaptation plan.

A Comparison of FFH/SSMA and DS/CDMA Communications in a Rician Fading Channel

  • Jeungmin Joo;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.497-500
    • /
    • 2000
  • In this paper, we compare the bit-error-rate performance of the fast-frequency-hopped spread-spectrum multiple-access (FFH/SSMA) and direct-sequence code-division multiple access (DS/CDMA) systems in a Rician fading channel. Each system has a same data rate, bandwidth and transmits over a Rician fading channel. The results illustrate tradoffs in performance between the FFH/SSMA and DS/CDMA systems as a function of the parameters such as average signal to noise ratio and processing gain. The performance of the FFH/SSMA system is shown to be less sensitive to the change of fading environments, while the change of processing gain and average signal to noise ratio gives considerable affect to the FFH/SSMA system compared with the DS/CDMA system. Without respect to the change of system parameters, for most of Rician fading channels (except non-fading channel), FFH/SSMA system gives better performance than DS/CDMA system in BBR < 10$\^$-3/.

  • PDF

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

A Study on the Design of a Digital Hearing Aids Signal Processing System in the Wavelet Transform Domain (WT평면에서의 디지탈 청각 보조 신호 처리 시스템의 설계)

  • 이현철;석광원
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.347-354
    • /
    • 1996
  • This paper presents digital hearing aids signal processing system in WT(wavelet transform) domain. For implementation of hearing aids in WT domain, the gain in frequency domain is approximated in WT domain. We also present the gain selection algorithm to deal with the change of input signal power. Most transform methods produce blocking effect, and this effect degrades the convergence rate of feedback canceller. As a solution, we proposed wavelet transform bascd feedback canceller. To evaluate the performance, we compared it with LOT (lapped orthogonal transform) method in the frequency domain. This system has not shown the blocking effect, and improves convergence rate as compared with the LOT based feedback canceller.

  • PDF

Regional Frequency Analysis for Future Precipitation from RCP Scenarios (대표농도경로 시나리오에 의한 미래 강수량의 지역빈도해석)

  • Kim, Duck Hwan;Hong, Seung Jin;Choi, Chang Hyun;Han, Dae Gun;Lee, So Jong;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.80-90
    • /
    • 2015
  • Variability of precipitation pattern and intensity are increasing due to the urbanization and industrialization which induce increasing impervious area and the climate change. Therefore, more severe urban inundation and flood damage will be occurred by localized heavy precipitation event in the future. In this study, we analyze the future frequency based precipitation under climate change based on the regional frequency analysis. The observed precipitation data from 58 stations provided by Korea Meteorological Administration(KMA) are collected and the data period is more than 30 years. Then the frequency based precipitation for the observed data by regional frequency analysis are estimated. In order to remove the bias from the simulated precipitation by RCP scenarios, the quantile mapping method and outlier test are used. The regional frequency analysis using L-moment method(Hosking and Wallis, 1997) is performed and the future frequency based precipitation for 80, 100, and 200 years of return period are estimated. As a result, future frequency based precipitation in South Korea will be increased by 25 to 27 percent. Especially the result for Jeju Island shows that the increasing rate will be higher than other areas. Severe heavy precipitation could be more and more frequently occurred in the future due to the climate change and the runoff characteristics will be also changed by urbanization, industrialization, and climate change. Therefore, we need prepare flood prevention measures for our flood safety in the future.

Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation (고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화)

  • Choi, Yoo-Rim;Lee, Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.

A Technique for Accurate Measurement of Power System Frequency (전력설비의 정밀주파수진단을 위한 기법)

  • Nam, S.B.;Lee, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.66-70
    • /
    • 2006
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, il requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.68-71
    • /
    • 2004
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

An Iterative Technique for Fast and Accurate Measurement of Power System Frequency (전력계통 주파수의 고속.정밀측정을 위한 반복기법)

  • Nam, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.92-95
    • /
    • 2003
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints. it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Technique for Fast Measurement of Power System Frequency (전력계통 주파수의 고속측정을 위한 기법)

  • Nam, S.B.;Kim, Jin-Su;Ma, Seok-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.145-149
    • /
    • 2005
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF