• Title/Summary/Keyword: Rate Test

Search Result 13,503, Processing Time 0.042 seconds

ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.928-940
    • /
    • 2017
  • An experiment using the $Prim{\ddot{a}}rkreisl{\ddot{a}}ufe$ Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg smallbreak loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

A Dissimilarity with Dice-Jaro-Winkler Test Case Prioritization Approach for Model-Based Testing in Software Product Line

  • Sulaiman, R. Aduni;Jawawi, Dayang N.A.;Halim, Shahliza Abdul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.3
    • /
    • pp.932-951
    • /
    • 2021
  • The effectiveness of testing in Model-based Testing (MBT) for Software Product Line (SPL) can be achieved by considering fault detection in test case. The lack of fault consideration caused test case in test suite to be listed randomly. Test Case Prioritization (TCP) is one of regression techniques that is adaptively capable to detect faults as early as possible by reordering test cases based on fault detection rate. However, there is a lack of studies that measured faults in MBT for SPL. This paper proposes a Test Case Prioritization (TCP) approach based on dissimilarity and string based distance called Last Minimal for Local Maximal Distance (LM-LMD) with Dice-Jaro-Winkler Dissimilarity. LM-LMD with Dice-Jaro-Winkler Dissimilarity adopts Local Maximum Distance as the prioritization algorithm and Dice-Jaro-Winkler similarity measure to evaluate distance among test cases. This work is based on the test case generated from statechart in Software Product Line (SPL) domain context. Our results are promising as LM-LMD with Dice-Jaro-Winkler Dissimilarity outperformed the original Local Maximum Distance, Global Maximum Distance and Enhanced All-yes Configuration algorithm in terms of Average Fault Detection Rate (APFD) and average prioritization time.

Effects of Thoracic Flexibility Exercise Program on Pain, Heart Rate Variability, and Depression in Patients with Chronic Low Back Pain (흉추 가동성 운동프로그램이 만성 요통 환자의 통증과 심박 변이도 및 우울증에 미치는 영향)

  • Park, Donghwan;Lee, Eunhyuk;Lee, Kangseong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.161-170
    • /
    • 2019
  • Purpose : This study aimed to investigate the effects of a thoracic flexibility exercise program on pain, heart rate variability (HRV), and depression in patients with chronic low back pain. Methods : Fifty patients with chronic low back pain participated in this study. Each participant performed a pre-test and post-test. The outcome measures evaluated were a visual analog scale, HRV test results (automatic activity, standard deviation normal to normal [SDNN], low frequency [LF], high frequency [HF], and LF/HF ratio), and the Beck Depression Inventory. Patients underwent conventional physiotherapy for 35 minutes per session. In addition, a thoracic flexibility exercise program (trunk rotation exercise, McKenzie exercise, and supine thoracic extension exercise) were performed 3 times per week for 4 weeks. Results : After the training period, the visual analog scale results showed a significant decrease in the post-test compared to the pre-test. Automatic activity, SDNN, LF, HF, and LF/HF ratio significantly increased in the post-test compared to the pre-test. The Beck depression inventory results significantly decreased in the post-test compared to the pre-test. Conclusion : This study demonstrated that a thoracic flexibility exercise program improves a visual analog scale, HRV (automatic activity, SDNN, LF, HF, and LF/HF ratio), and the Beck Depression Inventory in patients with chronic low back pain.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

A Study on Questionnaires through the Test-Retest Method of Questionnaire for the Sasang Constitution Classification II (사상체질분류검사지에서 검사-재검사법을 통한 설문 문항에 대한 연구)

  • Mi Ran, Shin;Go, Ho-Yeon;Jae-Hyok, Lee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.35 no.1
    • /
    • pp.35-45
    • /
    • 2023
  • Objectives We tried to examine the change in the test-retest response for the questionnaire itself regarding the QSCCII. Methods Tests were conducted twice times with an interval of 6 months between tests for test-retest reliability analysis. We examined the test-retest answer agreement rate (%) in all items of QSCCII . We conducted NcNemar analysis to examine test-retest reliability for 77 items selected from the QSCCII. Results The body shape-multiple-choice items showed a tendency of low test-retest agreement rate and most of the questions about when I was not well and when I felt my body condition improve showed an high test-retest agreement rate tendency in all items of QSCCII. As a result of the research on the selected 77 items, there was a significant change in the answer in item No.25, 58(in the item of Soeumin) item No.45, 103(in the item of Taeumin) and item No.87 (in the item of Soeumin) (Table.3, 4, 5, 6). Conclusion The QSCCII is shown as a questionnaire composed of mostly no significant response changes in test-retest in each item through this study. Some items were appropriately deleted in the process of developing the advanced model, but there are also items that should be considered further. It is thought that some items should be used after being refined in content and form.

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Quality of Sleep and Heart Rate Variability by Physical Activity in High School Students (고등학생의 신체활동에 따른 수면의 질 및 심박변이도)

  • Park, Min Sun;Choi, Mona;Lee, Hyangkyu;Lee, Myoungho
    • Child Health Nursing Research
    • /
    • v.21 no.3
    • /
    • pp.195-203
    • /
    • 2015
  • Purpose: This study was done to investigate quality of sleep and heart rate variability by the physical activity in high school students. Methods: A survey that measures physical activity and quality of sleep was distributed to 118 students at Y High School. Heart rate variability was obtained using the LXC3203 heart rate monitor. The data of 105 students were analyzed using descriptive statistics, t-test, x2-test, and ANOVA with $Scheff{\acute{e}}$ test. Results: Boys and students with part-time jobs had significantly higher physical activity. The quality of sleep was significantly high when the students were non-smokers, felt healthy, happy, less stressed, and satisfied with their school lives. Mean heart rate was significantly higher among girls, and standard deviation from normal to normal R-R intervals were high in boys. Physical activity had no significant relationships with quality of sleep and heart rate variability. Conclusions: Physical activity should be encouraged for high school students, especially for girls. An experimental study with different intensity and time of physical activity is recommended to examine the relationships with quality of sleep and heart rate variability in the future.

Excessive Leakage Measurement Using Pressure Decay Method in Containment Building Local Leakage Rate Test at Nuclear Power Plant (원전 격납건물 국부누설률시험에서의 압력감소법을 이용한 과다누설 측정 방법)

  • Lee, Won Kyu;Kim, Chang Soo;Kim, Wang Bae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.231-235
    • /
    • 2016
  • There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

Effect Mo Addition on Corrosion Property and Sulfide Stress Cracking Susceptibility of High Strength Low Alloy Steels

  • Lee, Woo Yong;Koh, Seong Ung;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.39-44
    • /
    • 2005
  • The purpose of this work is to understand the effect of Mo addition on SSC susceptibility of high strength low alloy steels in terms of microstructure and corrosion property. Materials used in this study are high strength low alloy (HSLA) steels with carbon content of 0.04wt% and Mo content varying from 0.1 to 0.3wt%. The corrosion property of steels was evaluated by immersion test in NACE-TM01-77 solution A and by analyzing the growth behavior of surface corrosion products. SSC resistance of steels was evaluated using constant load test. Electrochemical test was performed to investigate initial corrosion rate. Addition of Mo increased corrosion rate of steels by enhancing the porosity of surface corrosion products. However, corrosion rate was not directly related to SSC susceptibility of steels.

Deterioration and Residual Life of Grease for Sealed Ball Bearing (밀봉형 볼베어링용 그리이스의 노화와 잔류수명)

  • 최인혁;김정길;김지현;손성구
    • Tribology and Lubricants
    • /
    • v.18 no.4
    • /
    • pp.273-278
    • /
    • 2002
  • Grease deterioration of mineral oil type grease was investigated using sealed deep groove ball bearings (6203) and bearing life test rig. The bearing test was performed under 3,000 rpm and 245 N radial load at 120。C. Grease taken ken tested bearings was checked in using certain evaluation methods, for example, oxidation induction time (OIT), FT-IR peak intensity, leakage .ate, bleeding .ate, total acid number. (TAN) and bearing noise increase. Within these test conditions, OIT, TAN, bleeding rate were changed gradually in accordance with bearing operating time and showed useful indices for deterioration of grease.