• Title/Summary/Keyword: Rate Dependence

Search Result 928, Processing Time 0.03 seconds

A Data-driven Classifier for Motion Detection of Soldiers on the Battlefield using Recurrent Architectures and Hyperparameter Optimization (순환 아키텍쳐 및 하이퍼파라미터 최적화를 이용한 데이터 기반 군사 동작 판별 알고리즘)

  • Joonho Kim;Geonju Chae;Jaemin Park;Kyeong-Won Park
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.1
    • /
    • pp.107-119
    • /
    • 2023
  • The technology that recognizes a soldier's motion and movement status has recently attracted large attention as a combination of wearable technology and artificial intelligence, which is expected to upend the paradigm of troop management. The accuracy of state determination should be maintained at a high-end level to make sure of the expected vital functions both in a training situation; an evaluation and solution provision for each individual's motion, and in a combat situation; overall enhancement in managing troops. However, when input data is given as a timer series or sequence, existing feedforward networks would show overt limitations in maximizing classification performance. Since human behavior data (3-axis accelerations and 3-axis angular velocities) handled for military motion recognition requires the process of analyzing its time-dependent characteristics, this study proposes a high-performance data-driven classifier which utilizes the long-short term memory to identify the order dependence of acquired data, learning to classify eight representative military operations (Sitting, Standing, Walking, Running, Ascending, Descending, Low Crawl, and High Crawl). Since the accuracy is highly dependent on a network's learning conditions and variables, manual adjustment may neither be cost-effective nor guarantee optimal results during learning. Therefore, in this study, we optimized hyperparameters using Bayesian optimization for maximized generalization performance. As a result, the final architecture could reduce the error rate by 62.56% compared to the existing network with a similar number of learnable parameters, with the final accuracy of 98.39% for various military operations.

Growth and Photocurrent Properties of $CuGaSe_2$ Single Crystal ($CuGaSe_2$ 단결정 박막 성장과 광전류 특성)

  • K.J. Hong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.81-81
    • /
    • 2003
  • The stochiometric mixture of evaporating materials for the CuGaSe$_2$ single crystal thin films were prepared from horizontal furnace. Using extrapolation method of X-ray diffraction patterns for the polycrystal CuGaSe$_2$, it was found tetragonal structure whose lattice constant no and co were 5.615$\AA$ and 11.025$\AA$, respectively. To obtains the single crystal thin films, CuGaSe$_2$ mixed crystal was deposited on throughly etched GaAs(100) by the Hot Wall Epitaxy(HWE) system. The source and substrate temperature were 61$0^{\circ}C$ and 45$0^{\circ}C$ respectively, and the growth rate of the single crystal thin films was about 0.5${\mu}{\textrm}{m}$/h. The crystalline structure of single crystal thin films was investigated by the double crystal X-ray diffraction(DCXD). Hall effect on this sample was measured by the method of van der pauw and studied on carrier density and mobility depending on temperature. From Hall data, the mobility was likely to be decreased by pizoelectric scattering in the temperature range 30K to 150K and by polar optical scattering in the temperature range 150K to 293K. The optical energy gaps were found to be 1.68eV for CuGaSe$_2$ single crystal thin films at room temperature. The temperature dependence of the photocurrent peak energy is well explained by the Varshni equation then the constants in the Varshni equation are given by a=9.615$\times$ 10$^{-4}$ eV/K, and $\beta$=335K. From the photocurrent spectra by illumination of polarized light of the CuGaSe$_2$ single crystal thin films. We have found that values of spin orbit coupling ΔSo and crystal field splitting ΔCr was 0.0900eV and 0.2498eV, respectively. From the PL spectra at 20K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0626eV and the dissipation energy of the acceptor-bound exciton and donor-bound exciton to be 0.0352eV, 0.0932eV, respectively.

  • PDF

Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor (범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발)

  • Jong-kyu Cheon;Sunghwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.367-373
    • /
    • 2023
  • Aircrews and passengers are exposed to radiation from cosmic rays and secondary scattered rays generated by reactions with air or aircraft. For aircrews, radiation safety management is based on the exposure dose calculated using a space-weather environment simulation. However, the exposure dose varies depending on solar activity, altitude, flight path, etc., so measuring by route is more suggestive than the calculation. In this study, we developed an instrument to measure the cosmic radiation dose using a general-purpose Si sensor and a multichannel analyzer. The dose calculation applied the algorithm of CRaTER (Cosmic Ray Telescope for the Effects of Radiation), a space radiation measuring device of NASA. Energy and dose calibration was performed with Cs-137 662 keV gamma rays at a standard calibration facility, and good dose rate dependence was confirmed in the experimental range. Using the instrument, the dose was directly measured on the international line between Dubai and Incheon in May 2023, and it was similar to the result calculated by KREAM (Korean Radiation Exposure Assessment Model for Aviation Route Dose) within 12%. It was confirmed that the dose increased as the altitude and latitude increased, consistent with the calculation results by KREAM. Some limitations require more verification experiments. However, we confirmed it has sufficient utilization potential as a cost-effective measuring instrument for monitoring exposure dose inside or on personal aircraft.

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

Kinetic Studies on the Thermal Degradation of Ginsenosides in Ginseng Extract (Ginsenosides의 처리온도(處理溫度) 및 시간(時閭)에 따른 반응속도론적(反應速度論的) 연구(硏究))

  • Choi, Jin-Ho;Kim, Doo-Ha;Sung, Hyun-Soon;Kim, Woo-Jung;Oh, Sung-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.197-202
    • /
    • 1982
  • Kinetic study for the thermal degradation of ginsenosides in ginseng extract was conducted. The results indicate that the thermal degradation followed first order kinetics and rate constants varied substantially depending on the types of ginsenosides and heat treatment temperatures. Activation energy calculated by Arrhenius plots ranged from 16.80 kcal/mole to 30.10 kcal/mole and $Q_{10}$ values ranged from 2.01 to 3.49. Correlation coefficients between the change of ginsenoside contents by thermal degradation and heat treatment temperature were $0.995{\sim}0.999$. The dependence on temperatures of the decomposition rate constant of total ginsenoside can be expressed as $k=4.574{\times}10^8$ exp(8898.8/T).

  • PDF

The Effect of Contamination of Ion Source on Ionic Current of Quadrupole Mass Spectrometer (사중극 질량 분석기의 이온소스 오염이 이온전류에 미치는 영향)

  • Lee, K.C.;Park, C.J.;Kim, J.T.;Oh, E.S.;Hong, K.S.;Hong, S.S.;Lim, I.T.;Yun, J.Y.;Kang, S.W.;Shin, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.197-202
    • /
    • 2009
  • The long term stability of ion current of QMS has been one of key parameters for monitoring gas process in vacuum. The time dependence of ionic current was monitored while the pressure of nitrogen gas was kept at a fixed pressure by introducing the gas into vacuum chamber. The chamber was evacuated to ${\sim}3{\times}10^{-9}\;Torr$ to reduce background signals before the measurement. Two ion sources were tested; one had brownish or black color due to gas contamination and the other one was new, i.e. cleaner. At a nitrogen pressure of $1{\times}10^{-5}\;Torr$, the ionic currents measured by the contaminated ion source decreased faster with time. The decrease rate was respectively ${\sim}46%$ for cleaner one and ${\sim}84%$ for contaminated one after ${\sim}5.5%$ hours. In order to test the effect of filament material on the ion current decrease, we fabricated a tungsten(W) filament which consisted of two parts; one half was made of W and the other was coated with yttria. The similar decrease of ionic currents were shown for the two types of filaments, indicating that slight change of temperature of filament due to material difference i.e. baking effect could not improve the origin of ionic current decrease. Overall the decreasing rate of ionic current is more closely associated with contaminated ion source of QMS rather than its filament materials.

Effect of Temperature on Amino-Carbonyl Reaction (Amino-Carbonyl 반응(反應)에 미치는 온도(溫度)의 영향(影響))

  • Kim, Yong-Nyun;Kim, Chang-Mok;Han, Kang-Wan;Oh, Sung-Ki
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 1982
  • The thermal degradation of 0.05M glucose-arginine model system was occurred during heat treatment for 0$\sim$7 hours at $60{\sim}120^{\circ}C$. and the melanoid in formation was investigated as a function of temperature. The decomposition reaction of glucose and arginine, as well as the reaction of melanoidin formation, followed first-order kinetics, except the reaction at $120^{\circ}C$. and the rate constants ($hr^{-1}\times 10^3$) of those reactions were ranged from 14.20 to 837. 10. Temperature dependence of the rate constants was characterized by the Arrhenius equation, except the reaction at $120^{\circ}C$. The ranges of activation energy and $Q_{10}$ values were 12.122$\sim$18.142 kcal/mole and 1.65$\sim$2.12, respectively.

  • PDF

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

A Study on the Effect of Social Enterprises Characterics on Financial and Social Performance (사회적기업의 특성이 재무적 성과와 사회적 성과에 미치는 영향: CEO 특성을 중심으로)

  • Hwang, Sooo-Young;Kim, Yong-Duck
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2018.11a
    • /
    • pp.165-175
    • /
    • 2018
  • Since the 1997 financial crisis, large scale unemployment and poverty have become serious, and public and social job creation projects have been carried out. However, with the limitations of low-wage and short-term jobs, the need for long-term and high quality jobs gradually began to attract attention. In recent years, social enterprises have grown both quantitatively and qualitatively and interest in social enterprises has increased. And also it is interested in the determinants of success and failure of social enterprises in the academic field. In this study, we examined the effects of social enterprise characteristics on financial and social performance, and we analyzed empirically by using social enterprises registered in the Korea Social Enterprise Agency. The financial performance of the social enterprise is measured by the net income ratio, operating income ratio, and the return on asset. The social performance of the social enterprise is measured by total number of workers and the employment rate of the vulnerable social groups. The characteristics of the social enterprise include the CEO characteristics (gender, age, experience in operating the social enterprise), the firm size, and the elapsed time of the authentication. The results of the empirical analysis are as follows. First, as a result of analysis for the effect on financial performance, we found that the financial performance have a statistically significant positive relationship with firm size, organizational form, government subsidies and capital adequacy ratio. And it is found that the social performance have a statistically significant negative relationship with CEO age, credit debt dependence. Second, as a result of analysis for the effect on social performance, we foumd that total number of workers have a significant positive relationships with CEO gender, CEO age, and firm size, government subsidies, while total number of workers have a significant negative relationship with certification type and industry dummy. On the other hand, the employment rate of the vulnerable social groups have a siginificant positive relationship with CEO gender and certification type and It have not statistically significant relationship with the government subsidies and the firm size.

  • PDF

The Impact of Social Enterprises on the Financial and Social Performance: An Empirical Analysis in Korea (재무적·사회적 성과를 결정하는 사회적기업의 특성)

  • Hwang, Soo-Young;Kim, Yong-Deok;Koo, Inhyouk
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.14 no.2
    • /
    • pp.61-72
    • /
    • 2019
  • Since the financial crisis in 1997, large scale unemployment and poverty have become serious, but there has been a surge in public and social job creation projects. However, with the limitations of low-wage and short-term jobs, the need for long-term, high quality jobs gradually began to garner attention. In recent years, social enterprises have grown both quantitatively and qualitatively and interest in social enterprises has increased; more specifically, scholars are interested in the determinants of success and failure of social enterprises in the academic field. In this study, we examined the effects of social enterprise characteristics on financial and social performance. In particular, we empirically analyzed social enterprises registered in the Korea Social Enterprise Agency. The financial performance of the social enterprise was measured using the net income ratio, operating income ratio, and the return on asset. The social performance of the social enterprise was measured by the total number of workers and the employment rate of vulnerable social groups. The characteristics of the social enterprise included CEO characteristics (gender, age, experience in operating the social enterprise), firm size, and the elapsed time of authentication. The results of the empirical analysis are as follows. First, as a result of analysis for the effect on financial performance, we found that the financial performance has a statistically significant, positive relationship with firm size, organizational form, government subsidies, and capital adequacy ratio. And we found that the social performance has a statistically significant, negative relationship with CEO age and credit debt dependence. Second, as a result of analysis for the effect on social performance, we found that the total number of workers had a significant, positive relationship with CEO gender and CEO age, as well as firm size, government subsidies; whereas the total number of workers had a significant, negative relationship with certification type and industry dummy. Comparatively, the employment rate of the vulnerable social groups had a significant, positive relationship with CEO gender and certification type, but there was no statistically significant relationship with the government subsidies or firm size.