• Title/Summary/Keyword: RapidArc

Search Result 142, Processing Time 0.022 seconds

Pyrolysis/GC-Mass Spectrometry Analysis for Rapid Identification of Volatile Flavour Compounds of Accelerated Ripened Cheddar Cheese and Enzyme-Modified Cheese (단기숙성치즈 및 EMC 치즈의 휘발성 풍미성분 신속분석방법으로서 Pyrolysis/GC-Mass Spectrometry의 이용)

  • ;;;S.S.B. Haileselassie;V.A. Yaylayan;B.H. Lee
    • Food Science of Animal Resources
    • /
    • v.21 no.3
    • /
    • pp.256-264
    • /
    • 2001
  • Pyrolysis/GC-mass spectrometry(Hewlet-Packard 5890GC/mass selective detector, 5971 BMSD), interfaced to a CDS Pyroprobe 1500 was optimized for rapid analysis of flavour compounds in Cheddar cheese. Twenty flavour compounds, including aldehydes(4), ketones(4), fatty acids(10), alcohol(1), and hydrocarbon(1), were identified from Cheddar cheeses. In total, Twenty-three flavour compounds aldehydes(2), ketones(8), alcohols(3), fatty acids(7), lactone(1), benzene derivative(1) and amide(1) were identified from two samples of accelerated-ripened Cheddar cheese treated with the proteolytic enzymes of Lactobacillus casei LGY. In total, Twenty-one flavour compounds; aldehydes(2), ketones(5), alcohols(2), fatty acids(11), and lactone(1) were identified from enzyme-modified cheese(EMC) treated with the combination of the proteolytic enzymes of Lactobacillus casei LGY and commercial endopeptidase or lipase. However, All the flavour compounds identified by pyrolysis/GC/MS in samples of ARC and EMC were not determined whether they are recognized as typical Cheddar flavour or not. More studies were requested on the development of methods for a rapid and convienent analysis of dairy fermented products using pyrolysis/GC-mass spectrometry.

  • PDF

Effects of Additives and Sintering Method on the Properties of Light Aggregate Prepared from EAF Dust/Clay (첨가제와 소결방법이 EFA Dust/점토 소결체의 경량화에 미치는 영향)

  • 권영진;이기강;김유택;김영진;강승구;김정환;박명식
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.3
    • /
    • pp.309-316
    • /
    • 2003
  • EAF(Electric Arc Furnace) Dust classified as special wastes containing heavy metal contaminants may cause to damage an environment such as underground water contamination if they were not treated properly. The possibility of producing the porous sintered body made from EAF Dust/clay composition system was studied. Mixing of EAF Dust and clay was carried out using wet-mixing process and two different sintering methods such as rapid and normal heat treatment were tried. By observing density, porosity and microstructure of sintered bodies, it was found that the bloating phenomenon depend on the contents of C, where the liquid phase occur or not during the sintering process. To obtain a light-aggregate of porous body due to bloating, the rapid heating was better than the normal heating at sintering process.

Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma

  • Mbewe, Jonathan;Shiba, Sakhele
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.130-136
    • /
    • 2021
  • Purpose: The Halcyon radiotherapy platform at Groote Schuur Hospital was delivered with a factory-configured analytical anisotropic algorithm (AAA) beam model for dose calculation. In a recent system upgrade, the Acuros XB (AXB) algorithm was installed. Both algorithms adopt fundamentally different approaches to dose calculation. This study aimed to compare the dose distributions of cervical carcinoma RapidArc plans calculated using both algorithms. Methods: A total of 15 plans previously calculated using the AAA were retrieved and recalculated using the AXB algorithm. Comparisons were performed using the planning target volume (PTV) maximum (max) and minimum (min) doses, D95%, D98%, D50%, D2%, homogeneity index (HI), and conformity index (CI). The mean and max doses and D2% were compared for the bladder, bowel, and femoral heads. Results: The AAA calculated slightly higher targets, D98%, D95%, D50%, and CI, than the AXB algorithm (44.49 Gy vs. 44.32 Gy, P=0.129; 44.87 Gy vs. 44.70 Gy, P=0.089; 46.00 Gy vs. 45.98 Gy, P=0.154; and 0.51 vs. 0.50, P=0.200, respectively). For target min dose, D2%, max dose, and HI, the AAA scored lower than the AXB algorithm (41.24 Gy vs. 41.30 Gy, P=0.902; 47.34 Gy vs. 47.75 Gy, P<0.001; 48.62 Gy vs. 50.14 Gy, P<0.001; and 0.06 vs. 0.07, P=0.002, respectively). For bladder, bowel, and left and right femurs, the AAA calculated higher mean and max doses. Conclusions: Statistically significant differences were observed for PTV D2%, max dose, HI, and bowel max dose (P>0.05).

An Experimental Study on the Arc Stability Improvement of Underwater Wet Welding with Flux Ingredients (피복성분에 의한 수중용접봉의 아크 안정성 개선에 관한 실험연구)

  • 김복인;노창석;정교헌;김민남
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.73-79
    • /
    • 2001
  • Underwater wet bead-on-plate welds were experimentally performed on 11mm thick SS400 steel plate as base metal by using six different types of flux coated electrodes of 3.2mm diameter. Two kinds of different flux coated wet arc electrodes (UW-1, UW-2) were individually designed flux materials, three kinds of the electrodes (E4301, E4311, E4313) were terrestrial electrodes and the another one (TN20) was an imported underwater wet welding electrode. As results, the individually designed flux coated underwater electrode, UW-2 and TN20 had a good starting and the excellent arc stability compared with other electrodes. No significant difference of bead appearance could be detected, but the slag detachability of TN20 electrodes was relatively undesirable. By rapid cooling rate, the hardness value and the portion of martensite of HAZ were increased, but it was considerably maintain stable for TN20 and UW-2 electrodes. The individually designed flux coated electrode, UW-2 could be used in practice for underwater bead welds.

  • PDF

Development of Hybrid Extinction $SF_6$ Interrupter using Analytical and Experimental Method ($SF_6$ 자력팽창 소호부 개발에 관한 실험 및 해석적 고찰)

  • Sohn, J.M.;Kang, J.S.;Lee, B.W.;Kim, Y.K.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.696-698
    • /
    • 2001
  • This paper considers the research of the hybrid interrupter which adopts both rotating arc and thermal expansion technology. The operating principle of this device depends on rapid arc rotation due to the magnetic field created by the fault current through a coil which is mounted on contacts and also relies on the principle of thermal expansion created by arc energy in extinguishing chamber and finally causes pressure rise in expansion volume. To develope this type of interrupter, we introduced analytical analysis including electromagnetic and arc fluid simulation and experimental analysis including construction of current source generation facility and arc behavior measurements. In this research, the principle of the interrupting techniques are given and analytical and experimental results of hybrid interrupter which is developed by new technology is introduced.

  • PDF

Analysis of Simulation Results for Secondary Arc in 765kV single transmission line (765kV 1회선 선로의 2차아크 모의결과 분석)

  • Ahn, S.P.;Kim, C.H.;Park, N.O.;Ju, H.J.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.36-38
    • /
    • 2004
  • In many countries, including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for UHV transmission lines to ensure requirements for high reliability of main lines. But, because of the high voltage and long span of UHV lines, the secondary arc current flows across the fault point even after the interruption of the fault current. i.e. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. In Korea transmission lines, it is scheduled to energize 765kV single transmission line(79km) between Sin-Ansung S/S and Sin-Gapyeong S/S at June 2006. Therefore this paper analyzes characteristics of the secondary arc extinction on 765kV single transmission line using EMTP. Simulation results shows that the average value of the secondary arc is $30A_{rms}$ and the auto-extinction time of it is longer at closer point to Sin-Gapyeong S/S.

  • PDF

Influence of Couch and Collimator on Dose Distribution of RapidArc Treatment Planning for Prostate Cancer in Radiation Therapy (치료테이블과 콜리메이터가 전립선암 래피드아크 치료계획의 선량분포에 미치는 영향)

  • Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • We investigated the influence of photon energy, couch and collimator angle differences between arcs on dose distribution of RapidArc treatment planning for prostate cancer. RapidArc plans were created for 6 MV and 10 MV photons using 2 arcs coplanar and noncoplanar fields. The collimator angle differences between two arcs were $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$. The plans were optimized using same dose constrains for target and OAR (organ at risk). To evaluate the dose distribution, plans were analyzed using CI (conformity index), HI (homogeneity index), QOC (quality of coverage), etc. Photon energy, couch and collimator angle differences between arcs had a little influence on the target and OAR. The difference of dosimetric indices was less than 3.6% in the target and OAR. However, there was significant increase in the region exposed to low dose. The increase of V15% in the femur was 6.4% (left) and 5.5% (right) for the 6 MV treatment plan and 23.4% (left), 24.1% (right) for the noncoplanar plan. The increase of V10% in the Far Region distant from target was 54.2 cc for the 6 MV photon energy, 343.4 cc for the noncoplanar and 457.8 cc for the no collimator rotation between arcs.

Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

  • Ashamalla, Hani;Tejwani, Ajay;Parameritis, Ioannis;Swamy, Uma;Luo, Pei Ching;Guirguis, Adel;Lavaf, Amir
    • Radiation Oncology Journal
    • /
    • v.31 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods: Sixteen patients were studied. Prostate ($PTV_P$), right pelvic ($PTV_{RtLN}$) and left pelvic lymph nodes ($PTV_{LtLN}$), and organs at risk were contoured. $PTV_P$, $PTV_{RtLN}$, and $PTV_{LtLN}$ received 50.40 Gy followed by a boost to $PTV_B$ of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose ($D_{MEAN}$) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results: Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The $D_{MEAN}$ of bladder was within 2% of each other. The rectum $D_{MEAN}$ in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion: For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF