• Title/Summary/Keyword: RapidArc

Search Result 142, Processing Time 0.038 seconds

A Study on the Properties of Underwater Wet Arc Welding for the Mild Steels (연강의 습식 수중 아크 용접 특성에 관한 연구)

  • Kwak, H.H.;Kim, C.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.107-114
    • /
    • 2007
  • Underwater wet arc welds were experimentally performed on 11mm thick SS400 mild steel plate as base metal by using six different types of flux coated electrodes of 4.0mm diameter; KSKR, KSKT, USBL, JPUW, UWEA, and UWEB. As results, the developed flux coated underwater electrode had a good weldability compared with other domestic terrestrial electrodes. By rapid cooling rate, the hardness value of HAZ were increased by quenching effects. Mechanical properties for the multi-pass butt-welding specimen are also tested experimentally. The feasibility of the developed underwater electrode was experimentally studied and the results achieved in this wet arc welds have shown that the developed wet welding electrode UWEB can have a degree of integrity.

  • PDF

Photovoltaic Characteristics of Low-density Concentration GaAs Solar Cells with/without Anti-reflective Coating

  • Noh, Sam Kyu;Kim, Jong Soo;Kim, Jin Soo;Yu, Jae Su
    • Applied Science and Convergence Technology
    • /
    • v.23 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • We have studied photovoltaic characteristics of single-junction GaAs solar cells with/without an $MgF_2/ZnS$ anti-reflective coating (ARC) illuminated by low-density concentration (<10 suns). By the ARC deposition, the short-circuit current density ($J_{SC}$) and the fill factor (FF) are increased by $5mA/cm^2$ and 5% at a standard illumination (1 sun), respectively, and the resulted conversion efficiency is enhanced by 45%. In contrast with the cell with no ARC showing a rapid degradation with increasing concentration power, the efficiency of ARC-deposited cell remains almost constant as ($17.7{\pm}0.3$)% regardless of the concentration. It informs that ARC treatment is very effective in GaAs concentrator solar cells.

The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection (765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책)

  • Ahn, Sang-Pil;Kim, Chull-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

A comprehensive comparison of IMRT and VMAT plan quality for orbital lymphoma (안와 림프종 환자의 방사선치료를 위한 세기조절방사선치료와 용적세기조절회전치료의 전산화 치료계획에 대한 고찰)

  • Yoo, Soon Mi;Ban, Tae Joon;Yun, In Ha;Baek, Geum Mun;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.281-287
    • /
    • 2014
  • Purpose : The purpose of this study is to compare the plan quality of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of orbital lymphoma. IMRT, partial single arc(SA) and partial-double arc(DA) VMAT plans for four patients with orbital lymphoma treated at our institution were used for this study. Conformity Index(CI), Paddick's Conformity Index(PCI) and Homogeneity Index(HI) of planning target volume(PTV) were used to evaluate dosimetric quality of each plan. The Monitor Unit (MU), treatment time and dose of ipsilateral lens from each type of plan were measured for comparison. Materials and Methods : The CI of PTV for IMRT, SA and DA were measured as 0.88, 0.86, 0.92. The PCI of DA was the lowest as 1.33. Also HI of DA was the lowest in measured plans as 1.15. Mean dose of lens, lacrimal gland, optic chiasm, the opposite optic nerve and both orbit was analyzed with V30, V20, V10, V5. The result showed that the lowest dose in IMRT highest in SA in opposite lens, lacrimal gland, optic nerve, orbit. Results : Treatment time and average MU of IMRT was about three times higher than SA. Conclusion : Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating orbital lymphoma.

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Study of Polymer Rapid Setting Cement Concrete Using Electric Arc Furnace Oxidizing Slag Aggregate (전기로(電氣爐) 산화(酸化)슬래그 잔골재를 이용한 폴리머 속경성(速硬性) 시멘트 콘크리트 기초물성(基礎物性) 연구(硏究))

  • Jung, Won-Kyong;Gill, Yong-Soo;Kang, Seung-Hee
    • Resources Recycling
    • /
    • v.21 no.1
    • /
    • pp.30-40
    • /
    • 2012
  • Electric arc furnace slag is made in ironworks during steel refining, it is been increasing chemical and physical resistibility using ageing method of unstable state of melting steel slag for using concrete's fine aggregates. Which is been changing stable molecular structure of aggregates, it restrains moving of ion and molecule. In Korea, KS F 4571 has been prepared for using the electric arc furnace oxidizing slag to concrete aggregates(EFS). In this study, Electric arc furnace oxidizing slag is used in the PRCC(Polymer Rapid setting Cement Concrete) which is applied a bridge pavement of rehabilitation, largely. The results showed that the increment of compressive strength development by 10- 20%. The flexural strength of EFS-Con increased greatly as the electric arc furnace oxidizing slag changed. The compressive strength and flexural strength developed enough for opening the overlayed EFS-Con to the traffic after 4 hours of EFS-Con placement. The permeability of EFS-Con was evaluated as negligible due to its very low charge passed. Thus, EFS-Con could be used at repairing or overlaying the concrete at fast-track job sites.

Study on Cooling Characteristic Improvement in Underwater Wet Arc Welding of TMCP Steelplate (TMCP강의 습식수중 아크용접부의 냉각특성 개선에 관한 연구)

  • 김민남
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.113-124
    • /
    • 1992
  • The offshore industry created a need for quality wet weld repairs. Wet welding is a fast method of repair providing sound, structural quality welds. It requires less support equipment than a similar underwater dry weld repair or the alternative mechanical connections. Compared to welds made in air, underwater wet welds are plagued by increased hardness due to rapid quenching by the surrounding water. In this paper is described the experimntal study of improving the cooling rates of wet welds of TMCP steel plate by shielding around weld arc surroundings. The principal results of this experimental investigation can be summarized as follows : By shielding around weld arc surrounding, the cooling rates resulting from wet welds on TMCP steel plate could be lower than that of nonshielded wet welds and the fesibility on high quality of mecanical properties of wet weld on TMCP steel plate was carried out with shielded weld arc surrounding.

  • PDF

The Flow Analysis of Arc in LG Hybrid Interrupter Using PHOENICS Code (PHOENICS Code를 이용한 자력팽창 소호부 내 아크유동해석)

  • Lee, J.C.;Lee, B.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.44-46
    • /
    • 2001
  • This paper describes the use of the PHOENICS CFD package for the simulation of the high-current period of the arcing process in a hybrid rotating arc/auto expansion by interrupter. The operating principle of this device depends on rapid arc rotation due to the magnetic field created by the fault current through a coil which is mounted on contacts and also relies on the principle of thermal expansion created by arc energy in extinguishing chamber and finally causes pressure rise in expansion volume. This paper is divided into three main sections. The first gives a brief overview of the interrupter. The second section gives a full description of the methods used in the calculation. The final section presents some sample results for the hybrid interrupter.

  • PDF

A Basic Study on the Development of Domestic Underwater Wet Arc Welding Electrode (습식 수중 아크용접봉의 국산화개발에 관한 기초연구)

  • 김민남;김복인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1122-1129
    • /
    • 2001
  • Underwater wet arc welding process was experimentally investigated by using the six types of flux coated electrodes of 3.2 mm diameter and the KR-RA steel plate of 11 mm thickness as base metal. Two types of electrodes were domestic covered arc welding electrode(CR13, CR14) and another two types of wet welding electrodes(UWCS, TN20)were imported goods, and the other two type (UWX1, UWX2) were individually designed flux coated electrodes for experimental welding purpose. Main experimental results are summerized as follows: 1. It is ascertained that individually designed flux coated electrode(UWX1) could be used in practice with KR-RA steel plate for underwater wet arc bead welds. 2. Welding arc can be generated easily and considerably kept in stable using TN20 and UWX1 electrodes. 3. The micro Vickers hardness value and the portion of martensite in the HAZ were increased in all the electrodes by rapid cooling rate, but it is relatively maintain stable for UWCS, TN20 and UWX1 electrodes.

  • PDF

A Study on the High Dynamic Performance of the Inverter Arc Welder (인버터 아크용접기의 고성능제어에 관한 연구)

  • 김규식;정해천
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.40-44
    • /
    • 1997
  • Along with the rapid growth in microelectronics and power electronics technologies, various advanced control methods have been successfully implemented in real time and shown to be useful in controlling CO2 arc welding systems with high dynamic performance. In this paper, the slope of welding currents is controlled not to be so high in the case of short circuit welding mode. This results in less spatter. In addition, the data-base is constructed for the optimal welding conditions.

  • PDF