• Title/Summary/Keyword: Rapid test

Search Result 2,241, Processing Time 0.036 seconds

A Feasibility Analysis of Rapid Acquisition Test for Cement Fineness using Hydrometer (시멘트 인수검사 시 액체밀도계법에 의한 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Kim, Young-Tae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.29-34
    • /
    • 2018
  • In this research, regarding the cement supplied to ready mixed concrete plant, the feasibility of rapid acquisition test for cement fineness using hydrometer which used for early strength evaluation of concrete was analyzed. Additionally, regarding the rapid test with hydrometer control factors were provided. As a result of analysis, quality control using hydrometer was possible with the regressive equation obtained in five minute between density of suspension and fineness of cement powder. As the control factors, dispersing admixture, replacing kerosene as a medium, and temperature of cement and water were evaluated. According to the control factor evaluation, the tap water was optimum as a medium and calibration of keeping the temperature of water to $20^{\circ}C$ or correction factor was needed for density results. Finally, it is considered that the suggested rapid quality evaluation method using hydrometer is cheaper and easier method than currently used Blaine test.

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

The Sensitivity Comparison of Immunodiagnostic Assays for Diagnosing Dengue Fever

  • Zahoor, Muhammad;Bahadar, Haji;Uddin, Salah;Naz, Sumaira
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.4
    • /
    • pp.275-279
    • /
    • 2016
  • Dengue fever is a vector borne disease caused by a dengue virus. It is an RNA virus of the family flaviviridae, with different serotypes. Herein, we report our attempt to carry out a sensitivity comparison of immunodiagnostic assays for dengue fever in dengue positive patients. Blood samples from 189 volunteers were collected. To determine the sensitivity of the NS1 test, two different types of tests-immunochromatographic tri-line test and rapid dengue test (RDT)-as well as IgM and IgG capture ELISA were performed. The result of RDT has shown that 59.7% of volunteers were IgM positive and 50.2% were IgG positive. Conversely, the results from capture ELISA shows 79.8% and 59.7% for IgM and IgG, respectively. The sensitivity of the capture ELISA test for IgM and IgG was higher than that of immunochromatographic tri-line rapid test, but the specificity was lower. Therefore, to confirm dengue fever, we recommend performing more detailed, investigative tests since a single test may not be sufficient.

Reliability of Stool Antigen Tests: Investigation of the Diagnostic Value of a New Immunochromatographic Helicobacter pylori Approach in Dyspeptic Patients

  • Korkmaz, Huseyin;Findik, Duygu;Ugurluoglu, Ceyha;Terzi, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.657-660
    • /
    • 2015
  • Background: A diagnosis of H. pylori infection can be made by invasive or non-invasive methods. Several noninvasive diagnostic tests based on the detection of H. pylori stool antigen (HpSA) have been developed. The Genx H. pylori stool antigen card test is a new rapid, non-invasive test that is based on monoclonal immunochromatographic assay. The aim of this study was to determine its sensitivity, specificity, and diagnostic accuracy for diagnosing H. pylori infection in adult patients. Materials and Methods: A total of 162 patients were included in the study. A gastric biopsy was collected for histopathology and rapid urease testing. Stool specimens for HpSA testing were also collected. Patients were considered H. pylori positive if two invasive tests (histological and rapid urease tests) were positive. Results: Using the reference test, 50.6% of the samples were positive for H. pylori infection. The Genx H. pylori antigen test was positive in 19.7% of patients. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the Genx H. pylori antigen test were 51.6%, 96.0%, 88.8%, 76.1%, and 79.0%, respectively. Conclusions: The Genx H. pylori stool antigen card test is a new non-invasive method that is fast and simple to perform but provides less reliable results.

Chloride Permeability of High Strength Concrete (고강도 콘크리트의 염화물 침투특성)

  • ;;;Kawano, Hirotaka
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.985-990
    • /
    • 2001
  • Chloride permeability of high strength concrete(HSC) was investigated using saltwater pending test and rapid chloride permeability test by electrical potential(ASTM C 1202). The lower water-cement ratio concrete showed the lower diffusion coefficient of chloride. The relationship between the diffusion coefficient of chloride and charge passed by the rapid chloride permeability test could be obtained. This relationship appears to be an effective method for evaluating chloride permeability of low water-cement HSC.

  • PDF

HIV Screening Using the $OraQuick^{(R)}$ $ADVANCE^{TM}$ Rapid HIV-1/2 Antibody Test (OraQuick Test) in Dentistry: A Literature Review ($OraQuick^{(R)}$ $ADVANCE^{TM}$ Rapid HIV-1/2 Antibody Test를 이용한 치과에서의 인간면역결핍바이러스 검사: 문헌고찰)

  • Im, Jae-Hyung;Kim, Su-Gwan;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.286-291
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the use of OraQuick tests in previously reported articles. Methods: The literature was searched using Pubmed Medline with keywords, such as "OraQuick" or "rapid HIV test". Articles that included the specificity and sensitivity of this device were reviewed. Results: A total of 11 journal articles including 3 domestic articles were reviewed. The sensitivity of the OraQuick Test was reported to be 97.8 to 100% and its specificity was 98.8 to 100%. Conclusion: The results indicated that the simple OraQuick assay has proven to be accurate and it can be used to detect patients with HIV and to prevent the spread of HIV on test screens.

Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition (영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발)

  • Lee, Ji Eun;Joo, Yoon Ha;Lee, Jung Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

A Realization of the Process Chain from Reverse Engineering to Rapid Tooling (Reverse Engineering을 이용한 신속 기능성 시제품 제작)

  • 송용억;박세형;하성도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.841-845
    • /
    • 1996
  • Reverse engineering enables a fast creation of CAD model from an existing part without any technical drawing or digital data. This method of data acquisition is necessary in several industrial applications when the modification of an existing product design has to be performed and verified afterwards. In this paper, the surface of an existing ship propeller was measured by a tactile measuring system and the acquired point data of the surface were used for modeling of a solid model in CAD system. By using LOM and casting processes, an aluminum propeller for functional test was manufactured and then its accuracy was measured by a laser scanner and compared with the origin릴 CAD data. As the results show, the use of LOM as a rapid prototyping process and casting as a secondary process delivers a functional prototype propeller which can be used for test purposes.

  • PDF

Evaluation of Rapid Immunochromatographic Assay Kit for HBsAg-Screening Using Whole Blood

  • Shin, Hyeong-Soon;Heo, Tae-Ryeon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.5
    • /
    • pp.362-365
    • /
    • 2000
  • A rapid immunochromatographic assay kit using whole blood to screen hepatitis B surface antigen was developed and evaluated by using sera from 240 patients. The reference diagnosis was based on the results obtained with GENEDIA Anti-HBs Rapid kit which is very similar to the above kit except for the use of serum. The test demonstrated a good correlation with the reference immunochromatographic assay kit, that is, the sensitivity and the specificity of the kit was 100%, respectively. The rapid test kit using whole blood should be more convenient and useful for the diagnosis of hepatitis B virus because the kit does not need machines and time to prepare serum. In addition, this kit is safe from inadvertent infection during sample treatment because the blood is sterilized with hydrogen peroxide, eliminates the procedure required to prepare serum and reduces the possibility of exposure to infectious agents.

  • PDF

A Benchmark Study on the Stereo-lithography-type Rapid Prototyping Apparatus using Transparent Materials (투명 재료를 사용하는 광조형 방식 쾌속조형 장비의 성능 비교 시험)

  • Kim, Gi-Dae;Sung, Joo-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.138-145
    • /
    • 2007
  • Among various rapid prototyping processes, stereo-lithography process which can manufacture transparent prototype is known to be the greatest in the form & dimensional accuracy and surface roughness. In this paper, bench mark tests of 4 stereo-lithography-type rapid prototyping apparatus were carried out using transparent materials. The test includes measurement of mechanical properties, form accuracy, building speed and manufacturing cost. It was observed that ViperPRO of 3D systems is advantageous in the mechanical properties and building speed, RM600011 of CMET in sub-milli scale form accuracy and manufacturing cost, and relatively economical Eden500V of Objet is great in tensile strength at room temperature.