• 제목/요약/키워드: Rapid Heating

검색결과 391건 처리시간 0.032초

ZnO-Bi2O3계 세라믹스의 미세구조 및 전기적 특성 (Microstructure and Electrical Characteristics of ZnO-Bi2O3 Ceramics)

  • 이승주;한상목
    • 한국세라믹학회지
    • /
    • 제25권6호
    • /
    • pp.645-654
    • /
    • 1988
  • The microstructure and electrical characteristics of ZnO-Bi2O3 ceramics containing 5mol% Bi2O3 have been studied in relation to sintering temperature and mode. The distribution and thickness of Bi2O3 intergranular layer was varied with sintering temperature and mode. Intergranular layer was more homogeneous with increasing sintering temperature, when sintering by direct heating and rapid cooling mode showed the best distribution of intergranular layer. These microstructural changes affected electrical characteristics directly, at 140$0^{\circ}C$ and C mode obtained high value of electrical resistivity and nonlinear exponent. Varistor voltage decreased with increasing sintering temperature, increased with decreasing holding time at high temperature. Barrier voltage obtained by calculation was about 1.5V.

  • PDF

연소시험법에 의한 산화성물질의 위험성 평가 (Risk Evaluation of Oxidizing Substances by Burning Test Method)

  • 정국삼
    • 한국안전학회지
    • /
    • 제7권3호
    • /
    • pp.73-82
    • /
    • 1992
  • This paper was concerned with the risk evaluation of oxidizing substances by burning test method. The samples were prepared the heaped cone-shaped mixtures of solid oxidizing sub-stance with sawdust, and ignition of the sample was made on contact with heating wire inside the combution chamber that the temperature and humidity of atmosphere can be kept at $25^{\circ}C$ and 60% respectively. Accordingly, it were measured the combustivity effect of mixing ratio and amount of sample weight on the burning rate. As a result of burning test of these samples, it could be noticed that the case when the sawdust has so and 30 wt.% in the mixing ratio shows effective combustivity, and as the amount of sample weight was increasing, It showed more rapid burning time. So the average burning time could be obtained by considering the weighting factors to the parameters of the mixing ratio and the amount of sample weight. Finally, it was compared with the effects of cation and anion of oxidizing substances and also applied analytically to the classification and evaluation of oxidizing sub-stances as dangerous goods.

  • PDF

Sensorless Control for a PM Synchronous Motor in a Single Piston Rotary Compressor

  • Cho Kwan-Yuhl
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.29-37
    • /
    • 2006
  • A sensorless control for an IPM (Interior Permanent Magnet) synchronous motor in a single piston rotary compressor is presented in this study. The rotor position is estimated from the d-axis and q-axis current errors between the real system and a motor model of the position estimator. The torque pulsation of the single piston rotary compressor is compensated to reduce speed ripples, as well as, mechanical noise and vibration. The proposed sensorless drive enables the compressor to operate at a lower speed which increases energy savings and reduces mechanical noise. It also gives high speed operations by a flux weakening control for rapid air-cooling and heating of the heat pump air-conditioners.

Cure Characteristics of Metal Particle Filled DGEBA/MDA/SN/ zeolite Composite System for EMI Shielding

  • Cho, Young-Shin;Lee, Hong-Ki;Shim, Mi-Ja;Kim, Sang-Wook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.548-551
    • /
    • 1999
  • The cure characteristics of metal particle filled DGEBA/MDA/SN/ zeolite epoxy resin composite system for EMI shielding were investigated by dynamic DSC run method and FT-lR spectroscopy. As the heating rate increased, the peak temperature on dynamic DSC curve increased because of the rapid cure reaction. From the straight line of the Kissinger plot, the curing reaction activation energy and pre-exponential factor could be obtained. As the post-curing time at 15$0^{\circ}C$ increased, the glass increased the glass transition temperature or the thermal stability increased. When the post curing time is too long, the system filled with metallic Al particle can be thermally oxidized by the catalytic reaction of metal filler and the thermal stability of the composite for the EMI shielding application may be decreased.

  • PDF

열전냉각 모듈을 이용한 국소 냉각에 관한 연구 (A Study on the Hot Spot Cooling Using Thermoelectric Cooler)

  • 김욱중;이공훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.640-645
    • /
    • 2007
  • An experimental apparatus to show the hot spot cooling of an IC chip using a thermoelectric cooler is developed. The spot heating in very small area is achieved by the applying CO$_2$ laser source and temperatures are measured using miniature thermocouples. The active effects of thermoelectric cooler on the hot spot cooling system such as rapid heat spreading in the chip and lowering the peak temperature around the hot spot region are investigated. The experimental results are simulated numerically using the TAS program, which the performance characteristics such as Seebeck coefficient, electrical resistance and thermal conductivity of the thermoelectric cooler are searched by trial and error. Good agreements are obtained between numerical and experimental results if the appropriate performance data of the thermoelectric cooler are given.

  • PDF

X-선 회절 분석을 통한 고온 피해 시멘트 경화체의 성분 변화 분석 (Analysis of the Changes of composition of Hardened Cement at High Temperature by X-Ray Diffraction)

  • 지우람;박지웅;신기돈;이건철;허영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2017
  • In this study, the change of composition of cement hardened at high temperature through XRD was observed. The specimen was made of cement paste and the heating rate condition was applied at rapid thermal annealing (10.0℃ / min). The decrease of calcium hydroxide was not confirmed, but the calcium carbonate tended to be impossible or decreased after 800℃. Calcium silicate and larnite were observed to increase with increasing temperature. It is considered that silicic acid, which is a stable structure due to the decomposition of calcium silicate, is changed into a phase such as lime.

  • PDF

Temperature Controllable HPLC Column for Preparative Fractionation of Polymers

  • Im, Kyu-Hyun;Park, Hae-Woong;Kim, Young-Tak;Chang, Tai-Hyun
    • Macromolecular Research
    • /
    • 제16권6호
    • /
    • pp.544-548
    • /
    • 2008
  • An HPLC column with a self-contained temperature control device was constructed for preparative temperature programmed interaction chromatography. Two Peltier plates were attached to a large bore column ($120{\times}22\;mm$ i.d.) and the column temperature was controlled by PID mode feed back control. At a flow rate of 1.5 mL/min, the column temperature could be increased and decreased at a rate as high as $50^{\circ}C/min$ and $10^{\circ}C/min$, respectively, which is much faster than using a column jacket and bath/circulator. The rapid heating and cooling rates allows a high repetition rate of chromatographic fractionation. The performance of the temperature controllable column was demonstrated successfully by the fractionation of homo-polymer precursors from diblock copolymers.

Rapid Formation of Optically Active and Organosoluble Polyamides Containing L-Alaninephthalimide Side Chain via Microwave Irradiation

  • Mallakpour, Shadpour;Rafiee, Zahra
    • Macromolecular Research
    • /
    • 제17권11호
    • /
    • pp.901-906
    • /
    • 2009
  • Several aromatic optically active polyamides (PA)s were synthesized from 5-(2-phthalimidiylpropanoylamino)isophthalic acid with various aromatic diamines via direct polycondensation with triphenyl phosphite and pyridine in the presence of calcium chloride and N-methyl-2-pyrrolidone under microwave irradiation and conventional heating conditions. Under the optimized conditions, the reaction mixture was irradiated for 2 min. with a 100% irradiation power (900 W). The resulting polymers were obtained in high yield and moderate inherent viscosity ranging from 0.35 to 0.60 dL/g. All synthesized polymers showed excellent solubility in amide-type solvents. Thermogravimetric analysis revealed a 10% weight loss temperature and char yield at $600^{\circ}C$ in a nitrogen atmosphere of > $350^{\circ}C$ and > 58%, respectively, which suggests that the resulting PAs have good thermal stability.

Exothermic processes in nitric acid solutions imitating highly active raffinate

  • E.V. Belova;V.V. Kalistratova;A.S. Obedkov
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3808-3814
    • /
    • 2023
  • The thermal stability of nitric acid solutions after contact with non-irradiated and irradiated tributyl phosphate (TBP) and its solution in Isopar-M has been studied. It has been established that exothermic processes occur during heating due to the interaction of soluble radiolysis products and the decomposition of the extractant with nitric acid. Such processes can occur at temperatures below 100 ℃, but unlike a thermal explosion that occurs in seconds, they are longer in time and are accompanied by weak heat evolution. Their intensity depends on the composition of the extractant, the concentration of HNO3, and the volume ratio of the organic and aqueous phases. The presence of extractant degradation products in raffinates does not pose a risk of a rapid evolution of gaseous products during evaporation, however, the presence of reducing agents can significantly increase the intensity of the exothermic decomposition of raffinates.

모발 수분 함량 평가를 위한 가열 온도와 기준 수분 정량 조건 연구 (Study of Heating Temperature and Quantification Conditions of Standard Water for Evaluating Hair Water Content)

  • 송상훈;주장호;박현섭;손성길;강내규
    • 대한화장품학회지
    • /
    • 제50권1호
    • /
    • pp.11-18
    • /
    • 2024
  • 최근에 모발 케어 화장품 효능으로서 모발 보습 효과를 소구하려는 시도가 있지만 아직까지 모발 수분 추출을 어떤 온도에서 진행해야 하는지 평가법이 정해져 있지 않아 공인된 인체시험 평가가 없는 실정이다. 모발 수분 정량평가법을 확립하기 위해서 본 연구는 진행되었다. 모발 수분의 거동 패턴을 확인하기 위해 할로겐 수분 분석기로 온도를 다르게 하여 모발에 열을 가할 경우 수분 검출량은 가열 온도가 증가하면 계속 늘어나는 것을 확인하였다. 시차주사열량계로 모발의 흡열 반응 에너지를 평가한 결과 75 ℃ 부근에서 급격한 흡열 반응이 일어나는 특이한 현상을 관찰하였다. 인종별로 다른 모발에서도 이 현상은 관찰되었다. 모발 큐티클 장벽을 산화, 열로 손상시킨 모발에서는 급격히 상승하는 이 흡열 반응 온도가 조금 더 높은 77 ℃에서 일어났고, 이 모발을 극성오일 또는, 컨디셔닝 폴리머나 케라틴 단백질로 도포한 경우에는 73 ℃에서 관찰되었다. 이 반응이 모발 표면에서 어떤 영향을 미치는지 알아보기 위해서 원자현미경으로 마찰력을 관찰한 결과 75 ℃ 보다 높은 온도에서 가열할 때 큐티클 마찰력이 상승하고 그보다 높은 90 ℃에서는 변화가 없는 것을 관찰하였다. 마침내 75 ℃ 근처가 모발에 결합된 수분 분자의 탈착이 본격적으로 일어나는 임계온도임을 결론내렸다. 이를 통해 모발 수분을 검출해서 정량화하기 위한 조건으로 75 ℃가 가열온도로 최적합하고 이 때 검출된 수분량 10% 가량이 모발 케어 화장품 처리 전과 후를 비교할 수 있는 모발 수분 정량 기준값이 될 수 있음을 제시하였다.