• Title/Summary/Keyword: Raoult′s law

Search Result 61, Processing Time 0.023 seconds

Transient State Theory of Significant Liquid Structure applied to Binary Mixture, Benzene-Cyclohexane (이성분 액체 혼합물의 통계열역학적 연구)

  • Ahn, Woon-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.136-142
    • /
    • 1966
  • The Transient State Theory of Significant Liquid Structure has been successfully extended to binary mixture, benzene-cyclohexane system, which gives positive deviation from Raoult's law. The partition function has been derived, and from it various thermodynamic properties, such as total and partial vapor pressures, molar volumes, and excess entropies have been calculated at the temperatures $303.15^{\circ},\;\313.15^{\circ},\;and\;343.15^{\circ}K$. The calculated values agree satisfactorily with the experimental data.

  • PDF

Thermodynamic interaction parameter between Zn and Cu, Ag, In, Bi, Pb, Sn in Dilute cadmium alloy by Touch Instant electro-motive force method (순간접전기전력법에 의한 용융 Cd중의 Zn과 Cu, Ag, In, Bi, Pb 및 Sn와의 상위작용 파라미터)

  • 김대룡;윤겸하
    • Journal of the Korean institute of surface engineering
    • /
    • v.15 no.4
    • /
    • pp.192-207
    • /
    • 1982
  • A study has been made of the interaction parameters of Zn other elements in dilute solutesd solution of molten cadmium alloys over the temperature range of 450 to 570$^{\circ}C$. The experi-mental measurementss were made in a touch instant cell using a fusedd Licl-KCl electrolyte. The activity of zinc in binary and ternary solutions sexhibiteds a strong positive deviation from Raoult's law. The addition of silver, indium or lead increased the activity of zinc whereas addition of copper, bismuth or tin decreased the zinc activity slightly. The results for all the metallic solutions showed a linear dependence of reciprocal of ab-solute temperature over the experimental range. The interaction parameters obtained are as follows.

  • PDF

The Behavior of Solutes in Nonaqueous Solutions (Ⅱ). Relative Viscosities and Osmotic Coefficients of Urea, 1,3-Dimethylurea, Acetamide, and Propionamide (물아닌 용액에서의 용질의 행동에 관한 연구 (제2보). 요소, 1,3-디메틸요소, 아세트아미드와 프로피온아미드의 상대점도와 삼투계수)

  • Si-Joong Kim;Young-Kook Shin
    • Journal of the Korean Chemical Society
    • /
    • v.24 no.3
    • /
    • pp.209-217
    • /
    • 1980
  • The relative viscosities and osmotic coefficients of solutions of urea, 1,3-dimethyl-urea(DMU), acetamide(AA), and propionamide (PA) in dimethylsulfoxide(DMSO), water, methanol, and in ethanol have been measured at 25 and $45^{\circ}$C by viscometry and osmometry. Viscosity increment in nonaqueous solutions decreased with increasing of the partial molal volumes of the solutes, but in aqueous solution the result was inversed. Viscosity increment of aqueous solution was smaller than that of aqueous DMU solution, but that of nonaqueous urea solution was larger than that of DMU. Amides, however, showed similar viscosity increment in any solvent.Osmotic coefficients of aqueous solution of urea were larger than those of DMU. In the nonaqueous solutions urea exhibited larger deviation from Raoult's law than DMU. The results indicated that urea molecules break water-structure in water, self-associate in DMSO, and showed larger solute-solvent interaction in alcohols than DMU. It can be also confirmed that amides break alcohol structure to a greater extent than any other solutes.

  • PDF

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

The Measurement of Flash Point for Binary Mixtures of 2,2,4-Trimethylpentane, Methylcyclohexane, Ethylbenzene and p-xylene at 101.3 kPa

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.279-285
    • /
    • 2020
  • Laboratories and industrial processes typically involve the use of flammable substances. An important property used to estimate fire and explosion risk for a flammable liquid is the flash point. In this study, flash point data at 101.3 kPa were determined using a SETA closed cup flash point tester on the following solvent mixtures: {2,2,4-trimethylpentane + methylcyclohexane}, {2,2,4-trimethylpentane + ethylbenzene}, and {2,2,4-trimethylpentane + p-xylene}. The purpose of this work is to obtain flash point data for binary mixtures of 2,2,4-trimethylpentane with three hydrocarbons (methylcyclohexane, ethylbenzene, and p-xylene), which are representative compounds of the main aromatic hydrocarbon fractions of petroleum. The measured flash points are compared with the predicted values calculated using the GE models' activity coefficient patterns: the Wilson, the Non-Random Two-Liquid (NRTL), and the UNIversal QUAsiChemical (UNIQUAC) models. The non-ideality of the mixture is also considered. The average absolute deviation between the predicted and measured lower flash point s is less than 1.99 K, except when Raoult's law is calculated. In addition, the minimum flash point behavior is not observed in any of the three binary systems. This work's predicted results can be applied to design safe petrochemical processes, such as identifying safe storage conditions for non-ideal solutions containing volatile components.

Activity Measurement of Zn in Liquid Zn-Cd Alloy Using EMF Method (기전력법을 이용한 용융 Zn-Cd 합금중 Zn의 활동도 측정)

  • Jeong, Seong-Yeop;Jeong, U-Gwang;Park, Jong-Jin
    • Korean Journal of Materials Research
    • /
    • v.12 no.4
    • /
    • pp.283-289
    • /
    • 2002
  • The E.M.F of the galvanic cell with fused salt was measured to determine the activities of zinc at 700-820K over the entire composition range of liquid Zn-Cd alloys. The cell used was as follows: (-) W | Zn(pure) $Zn^{2+}(KCI-LiCl)$ | Zn(in Zn-Cd alloy) | W (+) The activities of zinc in the alloys showed positive deviation from Raoult's law over the entire composition range. The activity of cadmium and some thermodynamic functions such as Gibbs free energy, enthalpy, entropy were derived from the results by the thermodynamic relationship. The comparison of the results and the literature data was made. The liquid Zn-Cd alloy is found to be close to the regular solution. The concentration fluctuations in long wavelength limit, $S_{cc}(o)$, in the liquid alloy was calculated from the results.

Significant Liquid Structure of Binary Mixture, $C_6H_6-C_2H_4Cl_2$ (이성분 액체 혼합물의 통계열역학적 연구)

  • Ahn, Woon-Sun;Pak, Hyung-Suk;Chang, Sei-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.4
    • /
    • pp.215-221
    • /
    • 1965
  • The significant liquid structure theory is extended to binary mixture, benzene-ethylenechloride system. The partition function, applicable throughout the temperature range in which Raoult's law is satisfied is derived. The thermodynamic quantities such as total and partial pressures, molar volumes and mixing entropies are calculated from the partition function at the temperatures $293.15^{\circ},\;323.14^{\circ}\;and\;357.15^{\circ}K.$ The theoretical values, thus calculated, are found to agree with the experimental data in the literatures.

  • PDF

Development of a Fission Product Transport Module Predicting the Behavior of Radiological Materials during Severe Accidents in a Nuclear Power Plant

  • Kang, Hyung Seok;Rhee, Bo Wook;Kim, Dong Ha
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • Background: Korea Atomic Energy Research Institute is developing a fission product transport module for predicting the behavior of radioactive materials in the primary cooling system of a nuclear power plant as a separate module, which will be connected to a severe accident analysis code, Core Meltdown Progression Accident Simulation Software (COMPASS). Materials and Methods: This fission product transport (COMPASS-FP) module consists of a fission product release model, an aerosol generation model, and an aerosol transport model. In the fission product release model there are three submodels based on empirical correlations, and they are used to simulate the fission product gases release from the reactor core. In the aerosol generation model, the mass conservation law and Raoult's law are applied to the mixture of vapors and droplets of the fission products in a specified control volume to find the generation of the aerosol droplet. In the aerosol transport model, empirical correlations available from the open literature are used to simulate the aerosol removal processes owing to the gravitational settling, inertia impaction, diffusiophoresis, and thermophoresis. Results and Discussion: The COMPASS-FP module was validated against Aerosol Behavior Code Validation and Evaluation (ABCOVE-5) test performed by Hanford Engineering Development Laboratory for comparing the prediction and test data. The comparison results assuming a non-spherical aerosol shape for the suspended aerosol mass concentration showed a good agreement with an error range of about ${\pm}6%$. Conclusion: It was found that the COMPASS-FP module produced the reasonable results of the fission product gases release, the aerosol generation, and the gravitational settling in the aerosol removal processes for ABCOVE-5. However, more validation for other aerosol removal models needs to be performed.

The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa (Methanol, Ethanol, 2-Propanol 그리고 1-Butanol 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정 및 예측)

  • Oh, In Seok;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.1-6
    • /
    • 2015
  • Flash point is one of the most important variables used to characterize fire and explosion hazard of liquids. The lower flash point data were measured for the binary systems {methanol + 1-butanol}, {ethanol + 1-butanol} and {2-propanol + 1-butanol} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following activity coefficient models: Wilson, Non-Random Two Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC). The measured FP data agreed well with the predicted values of Raoult's law, Wilson, NRTL and UNIQUAC models. The average absolute deviation between the predicted and measured lower FP was less than 1.14 K.

The Measurement of Flash Point for Unflammable-Flammable Binary Mixtures(CCl4+o-Xylene and CCl4+p-Xylene) Using Open Cup Tester (개방식 장치를 이용한 난연성-가연성 이성분계 혼합물(CCl4+o-Xylene and CCl4+p-Xylene)의 인화점 측정)

  • Kim, Chang-Seob;Lee, Sungjin;Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.18-23
    • /
    • 2015
  • The flash point is used to categorize inflammable liquids according to their relative flammability. The flash point is important for the safe handling, storage, and transportation of inflammable liquids. The flash point temperature of two binary liquid mixtures($CCl_4+o-xylene$ and $CCl_4+p-xylene$) has been measured for the entire concentration range using Tag open cup tester. The flash point temperature was estimated using Raoult's law, UNIQUAC model and empirical equation. The experimentally derived flash point was also compared with the predicted flash point. The empirical equation is able to estimate the flash point fairly well for $CCl_4+o-xylene$ and $CCl_4+p-xylene$ mixture.