• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.032 seconds

Analysis of temperature effects on DC parameters of AlGaAs/GaAs HBT (AlGaAs/GaAs HBT의 DC 파라미터에 미치는 온도영향의 해석)

  • 김득영;박재홍;송정근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.12
    • /
    • pp.39-46
    • /
    • 1996
  • In AlGaAs/GaAs HBT the temperature dependence of DC parameters was investigated over the temperature range between 95K and 580K. The temperature dependence of DC parameters depends on the relative contribution of each of the current components suc as emitter-injection-current, base-injection-current, bulk recombination current, interface recombination curretn, thermal generation ecurrent and avalanche current due to impact ionization within the collector space charge layer in a specific temperature. In this paper we investigated the temperature effects on DC parameters such as V$_{BE,ON}$ current gain, input and output characteristics, V$_{CE, OFF}$, R$_{E}$, R$_{C}$ and analyzed the origins, and extracted the qualitativ econditions for a stable HBTs against the temperature variation. Finally, in order to keep HBTs stable with respect to the variation of temperature, the valance-band-energy-discontinuity at emitter-base heterojunction should be large enough to enhance the effect of carrier suppression at a relatively high temperature. In addition the recombination centers, especially around collector junction, should be removed and the area of emitter and collector junction should be identical as well.

  • PDF

Metabolic Heat Production and Rectal Temperature of Newborn Calves

  • Mundia, C.M.;Yamamoto, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.304-307
    • /
    • 1997
  • Rectal temperature (Tr), skin surface temperatures (Ts), and heart rate (HR) were measured continuously from birth (day 1) till day 7, while resting heat production (HP) was measured in a chamber on days 1, 3, 5 and 7, in order to study the characteristic variation of Tr in newborn calves by heat balance methods. Despite constant levels of milk being given to the newborn calves each day, daily mean resting HP was lowest on the day of birth, then increased to peak on day 3 and then decreased slightly thereafter. Daily mean HR was higher on days 2, 3 and 4, than on other days. Tr exhibited diurnal rhythms and daily mean Tr was low on day 1, high on day 3, and then decreased slightly after day 3. Daily average mean skin temperature (mTs) was similar on all days. Mean body temperature (Tb) exhibited diurnal rhythms and had a similar range between days, suggesting that heat balance and thermoregulation were carried out effectively on each day. The variation of Tb appeared to be synchronized with that of HP and suggested that newborn calves might use variations in the levels of Tb to facilitate the body's required levels of heart loss.

Hydraulic and Morphometric Characteristics of the Channel Bends (유로 만곡부의 수리 및 계량형태학적 특성)

  • Song, Jai Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 1992
  • A feature typical of natural rivers is the bend. The purpose of this study is to examine hydraulic and morphometric characteristics in channel bend reach by the deterministic approach. Cross section shape factor, "As" is suggested for a new cahracteristic factor of channel bend reach analysis. The variation of this new factor along the river reach showed the location of the concentration of the force due to the current all over the reach, that is curved or not. Some general meander factors are used for correlation with new factor suggested, and the applicability of "As" is verified. The range R/W values are concentrated 2~4, the meanning of this value can be regarded to the warning for bank erosion or breaking. And this paper dealt with prediction of cross section bed shape variation.

  • PDF

Absorption Rate Variation of TiNOx/Ti/Al Films Depending on N2 Gas Flow Rate (N2 Gas 유량에 따른 TiNOx/Ti/Al 흡수율 변화)

  • Kim, Jin-Gyun;Jang, Gun-Eik;Kim, Hyun-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.75-79
    • /
    • 2015
  • Ti was deposited on the Al substrate using DC magnetron sputtering with changing the $N_2$ gas for the possible application of a solar absorbing layer. $N_2$ gas ranged from 50 to 75 sccm was systematically applied in the 5 sccm interval and the variation of the absorption rate was investigated. Microstructural examination and elemental analysis indicate that Ti was reacted with $N_2$ gas and formed $TiNO_x$ compound. As compared with the film without any exposure of $N_2$ gas, absorption rate improved by more than 20%. Typically the average absorption of $TiNO_x$ fim with 65% of $N_2$ gas was about 99% in the visible range, and the average absorption was more than 90% in the infrared absorption region respectively.

Application of Geometry-Efficiency Variation Technique to Activity Measurement of $^{204}T1$ for 3-PM Liquid Scintillation Counting

  • Lee Hwa Yong;Seo Ji Suk;Kwak Ji Yeon;Hwang Han-Yull;Lee K. B.;Lee Jong Man;Park Tae Soon
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • 3-PM liquid scintillation counting using the geometry-efficiency variation technique has been applied to the activity measurement of $^{204}T1$, which decays to $^{204}Hg\;and\;^{204}Pb\;by\;{\beta}^-$ and E.C., respectively. The TDCR values K have been derived over a wide range, 0.78 < K < 0.97, by displacing the detectors up to 50 mm away from an unquenched liquid scintillation sample $^{204}Tl$. The derived plots of the logic sums of double coincidences $N_D(K)$ very K vary linearly in the observed regions. The fractions of losses due to electron capture decay have been taken into account by employing a PENELOPE Monte Carlo simulation. The calibrated activity is 102.3 kBq at a reference date of July 1st, 2002 (UT) with a combined uncertainty of $0.63\%$. This is consistent with the value determined by means of the CIEMAT/NIST method at KRISS.

Nitrogen Doping in Polycrystalline Anatase TiO2 Ceramics by Atmosphere Controlled Firing

  • Chang, Myung Chul
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.4
    • /
    • pp.374-386
    • /
    • 2019
  • A process for nitrogen doping of TiO2 ceramics was developed, whereby polycrystalline titania particles were prepared at 450-1000℃ with variation of the firing schedule under N2 atmosphere. The effect of nitrogen doping on the polycrystallites was investigated by X-ray diffraction (XRD) and Raman analysis. The microstructure of the TiO2 ceramics changed with variation of the firing temperature and the firing atmosphere (N2 or O2). The microstructural changes in the nitrogen-doped TiO2 ceramics were closely related to changes in the Raman spectra. Within the evaluated temperature range, the nitrogen-doped titania ceramics comprised anatase and/or rutile phases, similar to those of titania ceramics fired in air. Infiltration of nitrogen gas into the titania ceramics was analyzed by Raman spectroscopy and XRD analysis, showing a considerable change in the profiles of the N2-doped TiO2 ceramics compared with those of the TiO2 ceramics fired under O2 atmosphere. The nitrogen doping in the anatase phase may produce active sites for photocatalysis in the visible and ultraviolet regions.

Control of Environments in Greenhouse Using Programmable Logic Controller (PLC를 이용한 온실의 환경제어)

  • 김동억;조한근;김형준
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.599-606
    • /
    • 1998
  • This study was carried out to develop the control system with PLC and its operating software and to investigate its control ability of greenhouse environments. Two experimental greenhouses were controlled by PLC and ON/OFF controller, respectively. In greenhouse controlled by PLC, target values of air temperature, relative humidity and $CO_2$ concentration were automatically changed. In warm-water heating, the variation of air temperature was reduced to $\pm$ $0.6^{\circ}C$ by the method of proportional-integration(PI) control with an inverter. In ventilation, the variation of air temperature was reduced, since windows open and close with multistage by mutual relation formula among the target, indoor, and outdoor temperature. Relative humidity at daytime was maintained with range of 35% to 55% by PLC controlled fogger. $CO_2$ concentration was automatically controlled from 300 to 800 $\mu$molㆍ$mol^{-1}$ according to amount of solar radiation. The suppling amount and frequency of nutrient solution were controlled by total integrated solar radiation. Difference in the yield of cucumber in the greenhouse controlled by PLC and by ON/OFF controller was not significant at the 5% level.

  • PDF

Embedded System Design with COS LoRa technology (COS LoRa 기반의 임베디드 시스템 설계)

  • Hong, Seonhack;Cho, Kyungsoon;Yoon, Jinseob
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 2018
  • It is the approach of embedded system design that analyzes COS(Cut Out Switch) failure in the power distribution and an instantaneous breakdown of power distribution supply could cause the weakness of industrial competence and therefore we need to feed the stable power distribution with developing the technology of open-source embedded system. In this paper, we apply the LoRa technology which is the Internet of Things(IoT) protocol for low data rate, low power, low cost and long range sensor applications. We designed the hardware and software architecture setup and experimented the embedded system with network architecture and COS monitoring system including accelerometer for detecting the failure of distribution line and sensing the failure of its fuse holder by recognizing the variation and collision and afterwards sending the information to a gateway. With experimenting we designed the embedded platform for sensing the variation and collision according to the COS failure, monitoring its fuse holder status and transferring the information of states with LoRa technology.

Behavior of an Impinging Droplet on a Solid Surface with a Variation of Liquid Temperature (액체 온도 변화에 따른 평판 충돌 액적의 거동에 관한 연구)

  • Lee Dong Jo;Park Byung Sung;Chung Jin Taek;Kim Ho Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.330-339
    • /
    • 2005
  • An experimental study on the behavior of droplets impinging on a solid flat surface was carried out in the present study. Breakup of a liquid droplet impinging on a solid surface has been investigated experimentally for various liquids with different properties. The liquid droplet temperature and incident angle were chosen as major parameters. Liquid droplet temperature and incident angle varied in the range from $-20{\circ}C\;to\;30{\circ}C\;and\;from\;30{\circ}\;to\;60{\circ},$ respectively. It was found that the variation of droplet temperature influences upon the mean diameter and uniformity of droplets which were bounced out from the solid surface. With increase of incident angle the dispersion mass fraction increases, causing the decrease of liquid film flow rate. As the liquid temperature increases, dispersion mass fraction increases since the surface tension decreases.

AC susceptibility of current-carrying iron whiskers : Effect of current variation (전류에 의한 철단결정의 교류 자기감수율 : 전류 변화에 의한 효과 )

  • Jae-Gwang Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.179-184
    • /
    • 1995
  • The ac magnetic susceptibility of {100} iron whiskers as a function of currents is studied with and without external field. The ac susceptibility depends on the magnitude and the direction of the applied dc current when a small external field is applied along the magnetization of the central domain of the whisker. Variation of the central domain size accounts for the current-dependent response. The measured magnetic responses are explained, using a micromagnetic calculation based on a simple model, as a function of applied currents over a wide range except critical values.

  • PDF