• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.039 seconds

Storm-Time Behaviour of Meso-Scale Field-Aligned Currents: Case Study with Three Geomagnetic Storm Events

  • Awuor, Adero Ochieng;Baki, Paul;Olwendo, Joseph;Kotze, Pieter
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.133-147
    • /
    • 2019
  • Challenging Minisatellite Payload (CHAMP) satellite magnetic data are used to investigate the latitudinal variation of the storm-time meso-scale field-aligned currents by defining a new metric called the FAC range. Three major geomagnetic storm events are considered. Alongside SymH, the possible contributions from solar wind dynamic pressure and interplanetary magnetic field (IMF) $B_Z$ are also investigated. The results show that the new metric predicts the latitudinal variation of FACs better than previous studies. As expected, the equatorward expansion and poleward retreat are observed during the storm main phase and recovery phase respectively. The equatorward shift is prominent on the northern duskside, at ${\sim}58^{\circ}$ coinciding with the minimum SymH and dayside at ${\sim}59^{\circ}$ compared to dawnside and nightside respectively. The latitudinal shift of FAC range is better correlated to IMF $B_Z$ in northern hemisphere dusk-dawn magnetic local time (MLT) sectors than in southern hemisphere. The FAC range latitudinal shifts responds better to dynamic pressure in the duskside northern hemisphere and dawnside southern hemisphere than in southern hemisphere dusk sector and northern hemisphere dawn sector respectively. FAC range exhibits a good correlation with dynamic pressure in the dayside (nightside) southern (northern) hemispheres depicting possible electrodynamic similarity at day-night MLT sectors in the opposite hemispheres.

Occupational asthma related to indoor air pollution in a worker at an indoor air gun shooting range: a case report

  • Kwang Min Lee;Seungho Lee;Yoon-Ji Kim;Seung-eun Lee;Youngki Kim;Dongmug Kang;Se-Yeong Kim
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.13.1-13.12
    • /
    • 2023
  • Background: Indoor air pollution can cause and exacerbate asthma. We report a previously undescribed case of occupational asthma related to indoor air pollution in a worker at an indoor air gun shooting range and highlight the potential risk of developing occupational asthma in this environment. Case presentation: A 31-year-old man presented with dyspnea, cough, and sputum and was diagnosed with asthma complicated by pneumonia. Objective evidence of asthma was obtained by performing a methacholine bronchial provocation test. It was suspected that the patient had occupational asthma, which began one month after changing jobs to work within the indoor air gun shooting range. The highest peak expiratory flow (PEF) diurnal variability on working days was 15%, but the highest variation was 24%, with 4 days out of 4 weeks having a variation of over 20% related to workplace exposure. Conversely, the diurnal variability on the rest days was 7%, and no day showed a variation exceeding 20%. The difference in the average PEF between working and rest days was 52 L/min. PEF deterioration during working days and improvement on rest days were noted. Conclusions: The results obtained from the in-depth analysis of the PEF were adequate to diagnose the patient with occupational asthma. Exposure to indoor air pollution and lead and the patient's atopy and allergic rhinitis may have contributed to the development of occupational asthma.

A Study on Control Method for Built-in Type Spindle (Built-in Type 스핀들 구동을 위한 제어방법에 관한 연구)

  • Han S. Y.;Yoon J. M.;Park S. H.;Won C. Y.;Kim Y. R.;Choi C.;Lee S. H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.51-55
    • /
    • 2003
  • In this paper, the authors propose a new high performance Built-in Type spindle motor drive using vector-controlled technique at 15,000 r/min. Control method is changed by variation of motor speed in a conventional Built-in type spindle drive. In the drive system to be presented, the conventional vector control is used in the low-speed range, and the vector control without encoder is used in the high-speed range. Furthermore, in order to drive the motor from 0 to 15,000 rpm smoothly, the vector control with encoder in the low-speed range (from 0 to 8,000 rpm) is utilized and the vector control without encoder in the high-speed range (from 8,000 to 15,000 rpm) is utilized. This paper describes problem of control method in conventional spindle drive and proposes control method as variation of motor speed

  • PDF

Maximum number of total born piglets in a parity and individual ranges in litter size expressed as specific characteristics of sows

  • Freyer, Gertraude
    • Journal of Animal Science and Technology
    • /
    • v.60 no.5
    • /
    • pp.13.1-13.7
    • /
    • 2018
  • Background: The objective of this study was to underline that litter size as a key trait of sows needs new parameters to be evaluated and to target an individual optimum. Large individual variation in litter size affects both production and piglet's survival and health negatively. Therefore, two new traits were suggested and analyzed. Two data sets on 5509 purebred German Landrace sows and 3926 Large White and crossing sows including at least two parental generations and at least five parities were subjected to variance components analysis. Results: The new traits for evaluating litter size were derived from the individual numbers of total born piglets (TBP) per parity: In most cases, sows reach their maximum litter size in their fourth parity. Therefore, data from at least five parities were included. The first observable maximum and minimum of TBP, and the individual variation expressed by the range were targeted. Maximum of TBP being an observable trait in pig breeding and management yielded clearly higher heritability estimates ($h^2{\sim}0.3$) than those estimates predominantly reported so far. Maximum TBP gets closer to the genetic capacity for litter size than other litter traits. Minimum of TBP is positively correlated with the range of TBP ($r_p=0.48$, $r_g$ > 0.6). The correlation between maximum of TBP and its individually reached frequency was negative in both data sets ($r_p=-0.28$ and - 0.22, respectively). Estimated heritability coefficients for the range of TBP comprised a span of $h^2=0.06$ to 0.10. Conclusion: An optimum both for maximum and range of total born piglets in selecting sows is a way contributing to homogenous litters in order to improving the animal-related conditions both for piglets' welfare and economic management in pig.

Elimination of environmental temperature effect from the variation of stay cable force based on simple temperature measurements

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.137-149
    • /
    • 2017
  • Under the interference of the temperature effect, the alternation of cable force due to damages of a cable-stayed bridge could be difficult to distinguish. Considering the convenience and applicability in engineering practice, simple air or cable temperature measurements are adopted in the current study for the exclusion of temperature effect from the variation of cable force. Using the data collected from Ai-Lan Bridge located in central Taiwan, this work applies the ensemble empirical mode decomposition to process the time histories of cable force, air temperature, and cable temperature. It is evidently observed that the cable force and both types of temperature can all be categorized as the daily variation, long-term variation, and high-frequency noise in the order of decreasing weight. Moreover, the correlation analysis conducted for the decomposed variations of all these three quantities undoubtedly indicates that the daily and long-term variations with different time shifts have to be distinguished for accurately evaluating the temperature effect on the variation of cable force. Finally, consistent results in reducing the range of cable force variation after the elimination of temperature effect confirm the validity and stability of the developed method.

Geomagnetic Field Monitoring at King Sejong Station, Antarctica (남극 세종기지에서의 지자기 모니터링)

  • Kim, DonIl;Jin, YoungKeun;Nam, SangHeon;Lee, JooHan
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.1
    • /
    • pp.11-21
    • /
    • 2004
  • The variation of geomagnetic field and absolute magnetic field at the geomagnetic observatory of King Sejong Station has been measured with 3-component ring core fluxgate magnetometer, proton magnetometer and D-I magnetometer. With data obtained from King Sejong Station during 2003, thediurnal and annual variations of geomagnetic field were researched and compared with those at other observatories. The deviation of daily variation of magnetic field in antarctica decreased gradually during winter season due to sun effect. The rates of componental annual variation of magnetic field at King Sejong Station were calculated using the least-square method under the assumption that the annual variation of magnetic field is linear. The rates are -55.93 nT/year in horizontal intensity, -0.87 min./year in declination, 58.30 nT/year in vertical intensity, and -69.85 nT/year in total intensity of magnetic field. A remarkable variation was caused by the magnetic storms occurred on 29~30 October, which were so powerful that the variation was observed in mid latitudes as well as high latitudes. The values of variation are generally 1500 2000 nT in Antarctica including King Sejong Station, 350 500 nT in East Asia. The measurement of absolute magnetic field shows that ring core fluxgate magnetometer has relatively large error range under cold temperature.

  • PDF

Voltage-to Frequency Converter using BiCMOS (BiCMOS 기술을 이용한 전압-주파수 변환 회로)

  • 최진호
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.193-196
    • /
    • 2000
  • In this work, I propose a temperature stable voltage-to-frequency converter in which the output frequency is directly proportional to the input voltage. The output frequency range is from 20㎑ to 60㎑ and the difference between simulated and calculated values is less than about 5% for this range of output frequency. The temperature variation of sample output frequencies is less than ${\pm}$0.5% in the temperature range -25$^{\circ}C$ to 75$^{\circ}C$.

  • PDF

Time Series Observations of Atmospheric Radon Concentration in Seoul, Korea for an Analysis of Long-Range Transportation of Air Pollutants in the North-East Asia (동북아 오염물질 장거리이동 분석을 위한 서울시 대기 중 라돈농도의 시계열적 특성에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Kim, Ki-Youn;Jeon, Hyung-Jin;Kim, Jong-Cheol;Iida, Takao
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Atmospheric concentrations of radon had been continuously observed in Seoul, Korea since December 1999, as a tracer for long-range transport of air pollutants from China continent to Korea. In order to study radon as a tracer of long-range transport, it is important to know information about the atmospheric distribution and variation of radon concentration and its time variation. Atmospheric radon concentration are measured with electrostatic radon monitor(ERM) at Hanyang University located in Eastern area of Seoul. Air sample is taken into a vessel of ERM, and alpha particles emitted by radon daughters $Po^{218}$ are detected with ZnS(Ag) scintillation counter. Hourly mean concentrations and hourly alpha counts are recorded automatically. The major results obtained from time series observation of atmospheric radon were as follows : (1) The mean of airborne radon concentration in Seoul was found to be $7.62{\pm}4.11\;Bq/m^3$ during December $1999{\sim}January$ 2002. (2) The hourly variation of radon concentrations showed the highest in 8:00AM ($8.66{\pm}4.22\;Bq/m^3$) and the lowest in 3:00AM ($6.62{\pm}3.70\;Bq/m^3$) and 5:00AM ($6.62{\pm}3.39\;Bq/m^3$). (3) the seasonal variation of radon concentrations showed higher during winter-to-fall and lower during summer-to-spring. (4) Correlation between airborne radon concentration and the meteorological factors were -0.21 for temperature, 0.09 for humidity, -0.20 for wind speed, and 0.04 for pressure. (5) The mean difference of airborne radon concentration between Asian dust ($5.36{\pm}1.28\;Bq/m^3$) and non-Asian dust ($4.95{\pm}1.49\;Bq/m^3$) phenomenon was significant (p=0.08). We could identify time series distribution of radon concentration related meteorological factors. In addition, radon can be considered a good natural tracer of vertical dispersion and long-range transport.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Investigations on coefficient of variation of extreme wind speed

  • Xu, Fuyou;Cai, Chunsheng;Zhang, Zhe
    • Wind and Structures
    • /
    • v.18 no.6
    • /
    • pp.633-650
    • /
    • 2014
  • The uncertainty of extreme wind speeds is one key contributor to the uncertainty of wind loads and their effects on structures. The probability distribution of annual extreme wind speeds may be characterized using a classical Gumbel Type distribution. The expression that establishes the relationship between the extreme wind speeds at different recurrence periods and the corresponding coefficients of variation is formulated, and its efficacy is validated. The coefficients of variation are calibrated to be about 0.125 and 0.184 according to defined Chinese and US design specifications, respectively. Based on the wind data of 54 cities in China, 49 meteorological stations in the US, 3 stations in Singapore, the coefficients span intervals of (0.1, 0.35), (0.08, 0.20) and (0.06, 0.14), respectively. For hurricanes in the US, the coefficients range approximately from 0.3 to 0.4. This convenient technique is recommended as one alternative tool for coefficient of variation analyses in the future revisions of related codes. The sensitivities of coefficients of variation for 49 meteorological stations in the US are quantified and demonstrated. Some contradictions and incompatibilities can be clearly detected and illustrated by comparing the coefficients of variation obtained with different combinations of recurrence period wind data.