• Title/Summary/Keyword: Range of variation

Search Result 3,245, Processing Time 0.031 seconds

A Review of the Topographical Causes of Gloss Variation and the Effect on Perceived Print Quality

  • MacGregor, Michael A.
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.26-43
    • /
    • 2000
  • It is well accepted that gloss variation deteriorates the print quality and there are various objective ways to measure this. Several studies now have shown that the coefficient of variation in the octave band passed printed gloss image has an excellent correlation with ratings by an expert panel using a magnitude estimation scaling method. The correlation improves when the gloss level is also taken into account beyond that of the COV. There is also evidence that the correlation would improve even more if the gloss spatial distribution could be better accounted for. We show that much (at least 80% and perhaps up to 90%) of the gloss distribution can be accounted for by the paper topography over a wide range of dimensions (scale). Recent work has supported the role that microroughness and multiple surface scattering play in the gloss distribution. This offers the promise of showing that even a greater amount of gloss variationcan be explained by topography.

  • PDF

The Variation of Active Reactive Power of Fluorescent lamp Ballast as a Function of Potential (전원전압 변동에 따른 형광등용 안정기의 유.무 무효전력 변화)

  • 이진우;이석원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.14-16
    • /
    • 1999
  • This paper gives a basic data of fluorescent lamp equiprrents for calculating of receiving capacity. The fluorescent lamp equiprrent has non-linear cl1arocteristics of the active and the reactive power variation. Therefore we need real measurerrents. We tested and rreasured active and reactive power of fluorescent lamp equiprrents which use 4O[W] lamps and various ballasts. The potential variation range is A.C. 200~240[V].240[V].

  • PDF

Adaptive Neuro-Fuzzy Ingerence based Torque Model of SRM (적응 뉴로퍼지 추론기법에 의한 SRM의 토오크모델)

  • 홍정표;박성준;홍순일;김철우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.279-284
    • /
    • 1999
  • Although the switched reluctance motor (SRM) has a several advantages such as simple magnetic structure, robustness, wide range of speed characteristics and simple driving, it has a considerable inherent torque ripple and speed variation duet to the driving characteristics of pulse current waveform and the nonlinear inductance profile. The high torque ripple and speed variation inhibits wide application. The minimization of the torque ripple is very important in high performance servo drive applications, which require smooth operation with minimum torque pulsations. This paper presents the new SRM torque modeling technique for the control of instantaneous torque. The SRM is modeled by the database of torque profiles for every small variation in currents and rotor angles, which is inferred from the several measured data by the adaptive neuro-fuzzy inference technique. Simulation results demonstrating the effectiveness of proposed torque modeling technique are presented.

  • PDF

Electroencephalogram Variation by Electromagnetic Wave on Human Light Sensing (인체 광인식에 있어서 전자파에 의한 뇌파 변화)

  • Park Hyung-Jun;Yoon Jae-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.2
    • /
    • pp.82-89
    • /
    • 2006
  • The electroencephalogram generated by light stimulation in human body of dark adaption state was measured and analyzed in the cases that electromagnetic wave was put in and not put in, respectively. Shieldroom being able to interrupt the light and the electromagnetic wave of outer was constructed, and the experimental system being able to apply any light and any electromagnetic wave was designed. When the electromagnetic wave was applied to body or not, the variation characteristics of each component in the electroencephalogram were i3s follows. The 6 wave was increased and the $\alpha$ wave and the $\beta$ wave were decreased in the case that the electromagnetic wave was applied, and the variation range of the $\Theta$ wave was small. And the influence of electromagnetic wave on human body was that the appearance time of the $\beta$ wave was late, and it moaned that the time of visual recognition was delayed.

A Zero-Voltage-Switching Programmable Power Supply (영전압 스위칭 프로그래머블 전원장치에 관한 연구)

  • O, Deok-Jin;Im, Sang-Eon;Kim, Hui-Jun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.551-556
    • /
    • 2000
  • A zero-voltage-switching(ZVS) programmable power supply employing the ZVS active clamp forward converter is suggested. Through the analysis on operation region of the supply, the constant power region and the maximum current limit region are clearly identified. Furthermore, the duty ratio range corresponding to the variation range of the output voltages and the control scheme at the minimum duty ration region are presented. Finally, in order to vefity the validity of the operation for the proposed power supply, experimental evaluation results obtained on an 1kW prototype power supply for the 198~242VAC input voltage range(220VAC$\pm$10%), the 0~25V output voltage range, and the 100kHz switching frequency are presented.

  • PDF

Degradation Analysis of User Terminal EIRP and G/T due to Station-Keeping Variation of Stratospheric Platform

  • Ku, Bon-Jun;Ahn, Do-Seob;Baek, Dong-Cheol;Park, Kwang-Ryang;Lee, Seong-Pal
    • ETRI Journal
    • /
    • v.22 no.1
    • /
    • pp.12-19
    • /
    • 2000
  • Wireless communication systems using airship have been proposed in worldwide. The airship will be located at the stratosphere about $20{\sim}23\;km$ above the sea level. The position of airship will vary within the station keeping range with time due to the drag of the wind in the stratosphere. When the earth station antenna has a high gain without the tracking function, the antenna performance may be degraded by a small variation of the airship. This means that variation of airship location could result in serious degradation of the system performance. In this paper, degradation in earth station's Equivalent Isotropic Radiated Power (EIRP) and Gain to noise Temperature ratio (G/T) due to the stratospheric platform movements has been derived by calculating the deviation angle of the main beam directions between the earth station and the platform antenna. In this case, the antenna of the earth station has been assumed circular and/or patch array antennas.

  • PDF

A new hybrid control scheme for reduction of secondary diode voltage stresses Based on interleaved PFC Asymmetrical Half Bridge Topology (Asymmetrical 반브리지 컨버터의 이차측 다이오드 전압스트레스저감을 위한 새로운 하이브리드 제어기법)

  • Park, Nam-Ju;Lee, Dong-Yun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1416-1418
    • /
    • 2005
  • This paper presents a new hybrid control method of asymmetrical half-bridge converter(AHBC) with low voltage stresses of the diodes and interleaved PFC(power factor correction). The proposed new control scheme can observe variation of secondary diodes voltage stresses by variation of duty ratio and then decide the control portions which are asymmetrical control and PFM(Pulse Frequency Modulation). Therefore, the proposed control scheme has many advantages such as a low rated voltage of the secondary diodes, low conduction loss according to the low voltage drop and wide zvs range by load variation. Through simulation results, the validity of the proposed control scheme is demonstrated.

  • PDF

Yearly and Genotypic Variations in Seed Isoflavone Content of Local Soybean Cultivars

  • Yang, Kae-Jin;Chung, Ill-Min
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.2
    • /
    • pp.139-144
    • /
    • 2001
  • To analyze their isoflavones contents by HPLC analysis during two years on 60 collected old local traditional soybean varieties from various districts of Korea was conducted. There was a yearly variation in the seed isoflavon concentrations. The total contents on 5 isoflavones were in the range from 16.21mg/g to 25.21 mg/g and from 6.47 mg/g to 15.44 mg/g, in 1997 and 1998, respectively. Collected soybean from Gunsnsi-1(25.21 mg/g) in 1997 and from Gangjingun-3 (16.50 mg/g) in 1998 showed the highest amount of isoflavones as compared with other collected soybean varieties. The highest amount among 5 isoflavones was genistin as 48.45% and 49.73%, in 1997 and 1998, respectively, indicating the genotypic variation in seed isoflavon contents of local soybean cultivar. Our data suggest that it may be feasible for improving soybean variety with higher antioxiadtive activity and substances.

  • PDF

A Study on Spray Behaviors with Variation of Nozzle Diameter in the Diesel Combustion Chamber (분사 노즐 분공경에 따른 디젤 엔진 연소실내 분무 거동에 관한 연구)

  • 차경세;정우인;박찬국
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.3
    • /
    • pp.18-27
    • /
    • 2000
  • The spray models incorporated into the GTT code were tested for free spray, spray in swirling flows and the sprays impinging on a flat wall. And the validity of the models has been confirmed by comparing the calculated results with the experimental data. Using this code, the spray behavior in the diesel combustion chamber have been numerically analyzed for variation of nozzle diameter. Also, the effects of nozzle diameter in diesel combustion was investigated experimentally by measuring the performance in a D.I engine. This study provides the information for the spray characteristics and emissions with variation of nozzle diameter. As a result, it has shown that decreasing nozzle diameter resulted in improving smoke and specific fuel consumption in a middle speed range.

  • PDF

Photonic Glucose Sensor Using a Vertically Coupled Polymeric Microdisk Resonator (수직 결합형 폴리머 마이크로디스크 공진기를 이용한 광학적 글루코스 센서)

  • Kim, Gun-Duk;Son, Geun-Sik;Lee, Hak-Soon;Kim, K-Do;Lee, Sang-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1412-1415
    • /
    • 2008
  • A glucose biosensor using a microdisk resonator in polymeric waveguides was developed by observing either the shift in the resonant wavelength or the variation in the optical power. The deformation in the transfer curve of the vertically coupled resonator sensor resulting from the variation in the disk-to-ring coupling, which was incurred by the application of the target analyze, was suppressed. And the refractive index of the polymeric waveguide was devised to closely follow that of the analyze itself for enhancing the sensitivity of the sensor. The sensitivity and measurement range were observed to be respectively 0.14 pm/(mg/dL) and 1500 mg/dL (theoretically up to 4700 mg/dL, for the wavelength shift method and 0.04 dB/(mg/dU and 140 mg/dL the power variation scheme.