• 제목/요약/키워드: Range of motion(ROM)

검색결과 660건 처리시간 0.026초

The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charite$^{TM}$ in the Human Cadaveric Spine under Physiologic Compressive Follower Preload: A Comparative Study between Load Control Protocol and Hybrid Protocol

  • Kim, Se-Hoon;Chang, Ung-Kyu;Chang, Jae-Chil;Chun, Kwon-Soo;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권2호
    • /
    • pp.144-151
    • /
    • 2009
  • Objective: To compare two testing protocols for evaluating range of motion (ROM) changes in the preloaded cadaveric spines implanted with a mobile core type Charite$^{TM}$ lumbar artificial disc. Methods: Using five human cadaveric lumbosacral spines (L2-S2), baseline ROMs were measured with a bending moment of 8 Nm for all motion modes (flexion/extension, lateral bending, and axial rotation) in intact spine. The ROM was tracked using a video-based motion-capturing system. After the Charite$^{TM}$ disc was implanted at the L4-L5 level, the measurement was repeated using two different methods: 1) loading up to 8 Nm with the compressive follower preload as in testing the intact spine (Load control protocol), 2) loading in displacement control until the total ROM of L2-S2 matches that when the intact spine was loaded under load control (Hybrid protocol). The comparison between the data of each protocol was performed. Results: The ROMs of the L4-L5 arthroplasty level were increased in all test modalities (p < 0.05 in bending and rotation) under both load and hybrid protocols. At the adjacent segments, the ROMs were increased in all modes except flexion under load control protocol. Under hybrid protocol, the adjacent segments demonstrated decreased ROMs in all modalities except extension at the inferior segment. Statistical significance between load and hybrid protocols was observed during bending and rotation at the operative and adjacent levels (p< 0.05). Conclusion: In hybrid protocol, the Charite$^{TM}$ disc provided a relatively better restoration of ROM, than in the load control protocol, reproducing clinical observations in terms of motion following surgery.

목말밑관절 가동범위 측정방법에 관한 연구 (A Study of Measurement Methods for Subtalar Joint Motion)

  • 김기원;홍완성
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.57-64
    • /
    • 2010
  • Purpose: This study aimed to determine whether there are differences in subtalar joint range of motion (ROM) when using different measurement methods, and to determine inter- and intra-rater reliability of goniometry as used in clinical setting. Methods: Subjects were thirty-one healthy males and females (sixty-two ankles) living in Korea. Three raters with different clinical experiences measured inversion and eversion range of motion of the subtalar joint two times. Measurements were done with subjects prone (open kinetic chain) and standing (closed kinetic chain). Rater and measurement methods were based on analyzing differences in range of motion. Intra-class correlation coefficients (ICCs) were calculated to determine intra-rater and inter-rater reliability. Results: Mean subtalar jont range of motion for inversion ranged from $9.31^{\circ}$ to $11.94^{\circ}$ for eversion, it ranged from $6.73^{\circ}$ to $9.20^{\circ}$. The differences in ROM between raters and between measurement methods were significant (p<0.01). The ICCs for interrater reliability ranged from $0.02^{\circ}$ to $0.20^{\circ}$ for inversion and from $0.23^{\circ}$ to $0.39^{\circ}$ for eversion. Intrarater reliability ranged from $0.32^{\circ}$ to $0.78^{\circ}$ for inversion and from $0.45^{\circ}$ to $0.73^{\circ}$ for eversion. Conclusion: Subtalar joint inversion and eversion ROM show differences for measurement methods low reliability between different raters, and low to high intra-rater reliability within sessions.

운동발달 중재가 선천성 기운목 아동의 목빗근 두께와 목 운동범위에 미치는 영향 (The Effect of Motor Developmental Intervention on the SCM Muscle Thickness and Range of Motion in Subjects with Congenital Muscular Torticollis: A Pilot Study)

  • 김영민;한진태;이은주
    • 대한물리의학회지
    • /
    • 제12권4호
    • /
    • pp.133-138
    • /
    • 2017
  • PURPOSE: The purpose of this study was to investigate the effect of modified motor developmental intervention on the SCM muscle thickness and the range of motion (ROM) of neck in subjects with congenital muscular torticollis. METHODS: Thirteen subjects who had congenital muscular torticollis were participated in this study and they were offered the modified motor developmental interventions for 8 weeks by pediatric physical therapist. SCM thickness of affected and non-affected side and ROM of neck rotation were collected between before and after intervention. SCM thickness was measured by using Ultrasound Unit (IU 22, Ultrasound system, Philips, Netherlands) and ROM of neck was measured by using the goniometer (Arthrodial protractor, North coast, USA). Data were represented as means ${\pm}SD$. Paired t-test was used to determine the effect of interventions on the SCM muscle thickness and neck ROM. RESULTS: SCM thickness of affected side was significantly decreased after the modified motor developmental interventions and that of non-affected side was generally increased but it was not significantly difference between pre and post interventions. ROM of neck rotation and lateral flexion was significantly increased after interventions. CONCLUSION: These results suggested that the modified motor developmental interventions could improve the recovery of SCM muscle thickness and neck ROM.

어깨뼈 다이나믹 테이핑이 어깨 수술 환자의 통증과 기능장애 수준, 상지 자세와 관절가동범위에 미치는 영향 (The Effect of Scapular Dynamic Taping on Pain, Disability, Upper Body Posture and Range of Motion in the Postoperative Shoulder)

  • 박세진;김선엽
    • 대한물리의학회지
    • /
    • 제13권4호
    • /
    • pp.149-162
    • /
    • 2018
  • PURPOSE: The aim of this study was to investigate the effect of scapular dynamic taping on pain, disability, upper body posture, and range of motion (ROM) in the postoperative shoulder. METHODS: Twenty-two patients who underwent acromioplasty and rotator cuff repair surgery volunteered for this study. The subjects were randomly divided into an experimental group (EG, n=11) and a control group (CG, n=11). For the EG, exercise therapy, manual therapy, and scapular dynamic taping were applied for 6 weeks; for the CG, only exercise therapy and manual therapy were applied for 6 weeks. Shoulder pain, disability, upper body posture, and ROM were evaluated at baseline, after 3 weeks of intervention, and after 6 weeks of intervention. Assessment tools included quadruple visual analog scale (QVAS) for level of pain; shoulder pain and disability index (SPADI) for functional disability level; forward head angle (FHA), forward shoulder angle (FSA), and pectoralis minor index (PMI) for upper body posture; and ROM testing. RESULTS: Significant differences were observed between the EG and CG in SPADI total scores; internal rotation and external rotation ROM of the glenohumeral joint ; FSA ; and PMI. All groups showed statistically significant improvement in QVAS; SPADI; flexion; abduction; external rotation and internal rotation ROM of the glenohumeral joint; FSA; and PMI. CONCLUSION: These results suggest that, for patients who have undergone acromioplasty and rotator cuff repair surgery, the addition of scapular dynamic taping during therapy is effective for improvement of shoulder disability level, ROM, and upper body posture.

Effects of sling exercise and McKenzie exercise program on neck disability, pain, muscle strength and range of motion in chronic neck pain

  • Seo, Seung-Cheol;Choi, Jin-Young;Joo, Min-Young;Kim, Je-Hoon;Chang, Seul-Ki
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.40-48
    • /
    • 2012
  • Objective: The aim of this study was to compare sling exercise group to McKenzie exercise group in patients with chronic neck pain. Design: Two group pretest-posttest design. Methods: Twenty subjects who have chronic neck pain were randomly divided into sling exercise group (n=10) and McKenzie exercise (n=10). Sling exercise group (n=10) received sling exercise for 30 minutes per day, twice a week over a 4 week period. And the other group were exercised McKenzie exercise (n=8) for 30 minutes per day, twice a week over a 4 week period. Neck disability index (NDI), Visual analog scale (VAS), algometer, digital manual muscle tester (MMT) and cervical muscle strength and cervical range of motion (ROM) are closely measured to identify the effect of sling exercise and McKenzie exercise. Results: For NDI, VAS, algometer on both trapezius, both rotation of cervical muscle strength, both lateral flexion of cervical muscle strength, cervical extension of ROM and both lateral flexion of ROM were significantly increased after intervention in sling exercise group (p<0.05), For VAS, algometer on both trapezius, left (Lt.) rotation of cervical muscle strength, Lt. lateral flexion of cervical muscle strength, cervical flexion and extension of ROM and Lt. lateral flexion of ROM were significantly increased after than before intervention in McKenzie exercise group (p<0.05). Conclusions: These study outcomes clearly support the notion that sling and McKenzie exercise improved pain, Muscle strength and ROM of patients with chronic neck pain. These results suggest that sling and McKenzie exercise program is suitable for chronic neck pain.

  • PDF

Comparison of the immediate effect of hamstring stretching techniques on hamstring muscle range of motion, pressure pain threshold and muscle tone

  • Yu, June-Su;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.210-217
    • /
    • 2019
  • Objective: This study was conducted to compare the immediate effect of hamstring stretching techniques of static stretching, proprioceptive neuromuscular facilitation (PNF) hold-relax and PNF irradiation on the hamstring muscle. Design: Three-group pretest-posttest design. Methods: Fifty-one subjects with shortened hamstrings were randomly assigned to the static stretching group (n=17), PNF hold-relax group (n=17), and the PNF irradiation group (n=17). All subjects performed an active knee extension (AKE) test to assess for the lower extremity with a shortened hamstring. The static stretching group performed stretches by lifting their leg to the maximum extent (3 times, 30 seconds). The PNF hold-relax group performed maximal isometric contraction against the experimenter's resistance (3 times, 10 seconds). The PNF irradiation group performed maximum isometric contraction against the experimenter's resistance toward the direction of the body (5 times, 5 seconds). The pre and post-tests measured range of motion (ROM), pressure pain thresholds (PPT) and muscle tone. Results: There were significant differences in ROM and PPT between pre and post intervention in each group (p<0.05). There was a significant difference only in the ROM among groups (p<0.05). Post-hoc analysis showed that the changes in ROM occurred in the order of the PNF hold-relax group, static stretching group and PNF irradiation group (p<0.05). Conclusions: The findings of this study suggest that the PNF irradiation technique may improve ROM and may be used to improve ROM similar to other stretching techniques. Therefore, the PNF irradiation technique could be included in stretching programs and can be used as a suitable stretching method depending on the situation.

유방암 절제술과 견관절 수술을 한 여성의 견관절 관절가동범위, 통증수준, 기능수준, 견갑골의 자세 비교 (Comparison of Shoulder Range of Motion, Pain, Function, Scapular Position Between Breast Cancer Surgery and Shoulder Surgery Female Patients)

  • 이민지;김선엽;심재광
    • 한국전문물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.9-18
    • /
    • 2015
  • This study aimed to compare the characteristics of breast cancer surgery and shoulder surgery patients on the shoulder range of motion (ROM), degree of pain and dysfunction, and scapular position. This study was carried out with a total of 90 women: a breast cancer surgery group (BS, $n_1=30$), a shoulder surgery group (SS, $n_2=30$) and a control group ($n_3=30$). Shoulder ROM, the Quadruple Visual Analogue Scale (QVAS), the Shoulder Pain and Disability Index (SPADI), and the Scapular Index (SI) were used to assess shoulder function. Statistical analyses were performed using a one-way analysis of variance, crosstab test, and independent sample t-test. Post-hoc testing was carried out with Bonferroni test. There were significant differences in shoulder ROM when the BS and the SS were compared with the control group. However, there was no significant difference in ROM between the BS and SS. Furthermore, there was a significant difference in shoulder pain between both surgery groups, and there was greater shoulder dysfunction in the SS than in the BS. There was also a significant difference in upper extremity posture when the BS and the SS were compared to the control group. Finally, there was no significant difference in upper extremity posture between the BS and the SS. This study compared shoulder ROM, pain, dysfunction, and upper extremity postures between the BS and SS. While there were no significant differences in shoulder ROM, pain, and upper extremity posture between both surgery groups, the level of dysfunction was found to be significantly different. Therefore, health professionals managing for breast cancer surgery or shoulder surgery patients should consider these outcomes.

Effects of Extracorporeal Shock Wave Therapy on Ankle Function, Range of Motion, and Dynamic Balance in Patients with Chronic Ankle Instability

  • Lee, Su Bin;Kwon, Jung Won;Yun, Seong Ho
    • The Journal of Korean Physical Therapy
    • /
    • 제34권3호
    • /
    • pp.91-97
    • /
    • 2022
  • Purpose: This study investigated the short-term effectiveness of extracorporeal shock wave therapy (ESWT) on pain, the ankle instability, the ankle function, dorsiflexion range of motion (ROM), and dynamic balance in patients with chronic ankle instability (CAI). Methods: Eighteen participants were divided into an experimental (n=9) and control group (n=9). The ESWT in the experimental group was applied to the lateral collateral ligament in combination with the tibialis anterior whereas the ESWT was applied to the lateral collateral ligament of the ankle alone in the control group. Pain, the ankle instability, the ankle function, dorsiflexion ROM, and dynamic balance were measured using the Visual analog scale, Cumberland ankle instability tool, American Orthopedic Foot and Ankle Society ankle-hindfoot score, weight-bearing lunge, and Y-balance test, before and after ESWT intervention. Results: Significant interactions (group × time) and time effects were observed in the dorsiflexion ROM and dynamic balance. Bonferroni's post-hoc analysis showed that the experimental group revealed a more significant change in dorsiflexion ROM and dynamic balance than the control group. There was a significant time effect in the pain, the ankle instability, and the ankle function, but no significant interaction (group × time) was observed. Conclusion: The ESWT could improve the pain, ankle instability, ankle function, dorsiflexion ROM, and dynamic balance in patients with CAI. Furthermore, the ESWT combined with lateral ankle ligaments and tibialis anterior more improves the dorsiflexion ROM and dynamic balance.

에비안스-함베르크 스트레칭 방법이 고관절의 능동 가동범위와 우모각에 미치는 영향 (The Effects of Evjenth-Hamberg Stretching on Active Range of Motion of the Hip Joint and the Pennation Angle)

  • 천승철;장기연
    • 한국전문물리치료학회지
    • /
    • 제17권2호
    • /
    • pp.43-50
    • /
    • 2010
  • The purpose of this study was to investigate the effects of Evjenth-Hamberg stretching on the active range of motion (ROM) of the hip joint and the pennation angle of the semitendinosus muscle. Eighty healthy adults participated in this study. The active ROM of the hip joint was measured by a goniometer and the pennation angle of the semitendinosus muscle was measured by ultrasonographic imaging (USI). Both ROM and pennation angle were recorded before and after the static stretching and the Evjenth-Hamberg stretching, respectively. Data were analyzed using paired t-lest and independent t-test at p<.05. The results were as follows: 1) The active ROM of the hip joint increased significantly after both stretching interventions compared with the baseline (p<.001). However, the active ROM of the hip joint increased significantly in Evjenth-Hamberg stretching compared with static stretching. 2) The pennation angle decreased significantly after both stretching interventions compared with the baseline (p<.001). However, the pennation angle decreased significantly in Evjenth-Hamberg stretching compared with static stretching. 3) Reliability data showed that there was a high consistency in USl measurements (ICC=.978). Our findings suggest that the Evjenth-Hamberg stretching was more effective than static stretching in increasing the active ROM of the hip joint and decreasing the pennation angle of the semitendinosus muscle.

정적 스트레칭과 에비안스-함베르크 스트레칭이 슬관절의 관절가동범위의 변화에 미치는 영향 (The Effects of Static Stretching and Evjenth-Hamberg Stretching on Range of Motion of Knee Joint)

  • 이현희;육동원;고의석;박윤식;이한우
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.37-43
    • /
    • 2005
  • The purpose of this study was to examine the effects of static stretching and Evjenth-Hamberg stretching the on range of motion (ROM) of the knee joint. The subjects were composed of twenty healthy males without weight-training experience. The ROM of the knee joint was measured by using an En-Knee. Three tests (performed on the 1st week, 4th week, and 8th week) were conducted to examine the change of each variable. Data were analyzed with a $2{\times}3$ analysis of variance (group${\times}$test) for repeated measures on last factor through SPSS 10.0. The data analysis revealed the change in the ROM was dependent on the stretching method. The results were as follows: The ROM was improved in both methods by each time, but the E-HS was more improved than the SS. In conclusion, this study indicated that the E-HS is more efficient than the SS on the ROM of the knee joint.

  • PDF