• 제목/요약/키워드: Range of motion(ROM)

검색결과 670건 처리시간 0.025초

견관절 충돌증후군 환자에 대한 삼각근 억제 테이핑이 견부 통증과 기능수행 수준, 근력, 관절가동범위에 미치는 즉각적 영향 (The Initial Effect of Deltoid Inhibition Taping on Shoulder Pain, Function, Strength Level and Range of Motion in Patients With Shoulder Impingement Syndrome)

  • 한기성;김선엽
    • 대한물리의학회지
    • /
    • 제6권3호
    • /
    • pp.341-351
    • /
    • 2011
  • Purpose : The purpose of this study was to determine the initial effects of deltoid inhibition taping to Pain, Function, Strength, ROM in shoulder impingement syndrome (SIS). Methods : This study is 28 patients(male 16, female 12) with shoulder impingement syndrome(SIS).The experimental group received deltoid inhibition taping and the control group had sham taping. Outcome variables measured degree of pain, disability, strength, and range of motion at pre-post intervention. The changes between pre-post interventions are analyzed by a repeated measure ANOVA test. Results : Pain and disability index significantly decreased (p<.05), and the rate of change in pain and disability level of the experimental group increased significantly more than control group (p<.05). Strength and range of motion significantly increased (p<.05), but the rate of change of the two groups showed no significant difference (p>.05). Conclusion : These results suggest that deltoid inhibition taping was initial effective in decreasing pain and disability in SIS patients.

뇌졸중 환자의 경직 및 관절가동범위, 균형에 간섭전류 치료가 미치는 효과 (The Effects of Interferential Current therapy on Spasticity, Range of Motion, and Balance Ability in stroke Patient)

  • 김보용;최원호
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.187-194
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the effects of interferential current therapy (ICT) on spasticity, ROM, and the balance function in patients with stroke. Methods: 30 inpatients with stroke were randomly divided into 2 groups: the ICT group (n=15) and the placebo-ICT group (n=15). Two groups have got the traditional rehabilitation for 30 minutes before applying either ICT or placebo-ICT stimulation. The stimulus of ICT has been applied to gastrocnemius at the level of 100 Hz, two times of sensation threshold, while the placebo-ICT group has put on the electrode without electrical stimulus. To assess spasticity in ankle, the modified Ashworth scale (MAS) was used, and goniometer was applied to measure the passive range of motion (PROM). Also, the Berg Balance Scale (BBS), the Timed-up and go (TUG), and the Functional Reach Test (FRT) were carried out to examine the balance ability. Results: The ICT group showed a significant reduction of spasticity and significantly increased PROM than the placebo-ICT group (p<0.05). The placebo-ICT group did not show significant changes in the BBS, the TUG, and the FRT, while the ICT group significantly improved the BBS, the TUG, and the FRT (p<0.05). Conclusion: Our results demonstrated that ICT applied to gastrocnemius effectively decreased spasticity and improved range of motion and balance function in patients with stroke.

지연발생근육통에 대한 테이핑 처치가 통증정도와 가동성 회복에 미치는 영향에 관한 사례연구 (A Case Study of Taping Therapy Effects on Range of Motion and Pain in Delayed Onset Muscle Soreness)

  • 박래준;이문환
    • The Journal of Korean Physical Therapy
    • /
    • 제14권4호
    • /
    • pp.331-341
    • /
    • 2002
  • This case study was peformed to assess the effectiveness of taping therapy for the patient who have delayed onset muscle soreness(DOMS ). The results were as follows: 1. Pain degree of VAS was decreased at every taping therapy. 2. The range of motion of ankle joint was increased at every taping therapy. 3. Diameter of calf muscle was increased at every taping therapy. 4. Pattern of gait was normalized at every taping therapy. We found improve of pain degree, ROM of ankle joint, diameter of calf muscle, and pattern of gait. Therefore we can infer that taping therapy had effectiveness to those who had DOMS.

  • PDF

3차원 아바타를 이용한 관절 가동 범위 시각화 시스템 개발 (Development of Range of Motion Visualization System using 3D Avatar)

  • 윤창락;장윤섭;김재철
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2022년도 추계학술발표대회
    • /
    • pp.303-304
    • /
    • 2022
  • 근골격계 질환 재활환자들의 신체 능력을 평가하기 위한 주요 측정 도구로 관절 가동 범위(ROM: Range of Motion)가 사용된다. 본 논문에서는 근골격계 환자들의 재활운동을 통한 관절 가동 범위 정보를 시각적 이해하기 용이하도록 서비스하기 위하여 3차원 아바타를 이용한 관절 가동 범위 시각화 시스템을 제안한다. 제안하는 3차원 아바타를 이용한 관절 가동 범위 시각화 시스템은 근골격계 질환 재활환자들의 관절 가동 범위 데이터를 3차원 아바타의 대응하는 관절 작동 범위로 사상하고 다양한 시점으로 시각화하거나 애니메이션으로 재현함으로써 재활 수준의 변화를 직관적으로 제공할 수 있다.

기능적 전기자극 치료가 편마비 환자의 균형에 미치는 영향 (Effects of Functional Electrical Stimulation on the Balance of Hemiplegic Patients)

  • 김용철;이석민;송창호
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.97-111
    • /
    • 2004
  • This study, adopting the pretest-post test experimental study, is designed to find out how the functional electrical stimulation makes effect on the balance of a patient with spasticity of the ankle plantarflexor muscle caused by hemiplegic after stroke. The 46 subjects for this study were randomly sampled out of the patients who were hospitalized from September 1, 2003 to November 30, 2003 in H sanitarium in Yangpyung. The patients were with spasticity of the ankle plantarflexor muscle caused by hemiplegic after stroke and able to walk without supporting implements. The purpose of the study is firstly to analyze the change of ROM, FRTof a patient with spasticity of the ankle plantarflexor muscle when the functional electrical stimulation is applied and secondly to find out how the sex, age, height, weight, part of the diagnosis, duration of pain, experience of relapse and getting hurt from a fall of a patient make effect on the change. The experimental group for the study is divided into two to compare the differences of the effect. The exercising treatment only was performed for the conrtol group, and the functional electrical stimulation to the ankle dorsiflexor muscle as well as the exercising treatment was applied to the experimental group. The ROM test was performed to check the range of motion of the ankle with a double armed universal goniometer. The test was done 3 times to take an average. FRT were performed to check the balance. The statistical test was conducted using the SPSS 10.0/PC program by means of the following methods: χ2-test and t-test for testing homogeneity between the groups; paired t-test, independent sample t-test, F-test, and two-way ANOVA for analyzing the changes before and after the treatment. The levels of statistical significance of all the data were maintained at p<.05. According to the test, ROM has more decreased in experimental group than in control group when the functional electrical stimulation was applied only to the experimental group. However, the significant statistic difference was not shown (p=.059). FRT showed remarkable differences in the experimental group compared to the control group, showing the significant statistic difference (p=.000). On the one hand, the change of ROM, FRT related with the sex, age, height, weight, part of the diagnosis, and experience relapse was a meaningless minimum value. The change of ROM related to the duration of pain and the experience of falling down was also meaningless. However, FRT showed significant statistic difference (p<.05). According to the test above, the application of functional electrical stimulation to a patient with spasticity of the ankle dorsiflexor muscle caused by hemiplegic after stroke makes significant effect on the balance of a patient, but the result has nothing with the sex, age, height, weight, part of the diagnosis, duration of pain, experience of relapse and getting hurt from a fall of a patient. However, it is regarded to give contribution to the balance improvement of a patient. Therefore, this study expects to be a valuable clinical material for a patient with spasticity.

  • PDF

탄력밴드를 이용한 PNF 운동이 유방암 절제술에 속발한 상지 림프부종 환자의 부종, 관절가동범위 및 통증에 미치는 영향 -열린 홀딩과 닫힌 홀딩의 차이- (The Effects of Proprioceptive Neuromuscular Facilitation (PNF) Using Elastic Bands on Edema, Range of Motion, and Pain in Post-Mastectomy Patients with Upper Limb Lymphedema: Differences between Open-Hand and Closed-Hand Grips)

  • 조예진;이상열
    • PNF and Movement
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2020
  • Purpose: This study was conducted to examine the effects of a PNF intervention using elastic bands on edema, range of motion (ROM), and pain in post-mastectomy patients with upper limb lymphedema, according to their hand grip type. Methods: The subjects were 14 female patients who were at Stage II lymphedema after undergoing mastectomy for Stage II breast cancer. They were randomly divided into an experimental group (n =7) and a control group (n = 7). Both groups participated in a treatment program four times (one time under the therapist's instructions and three times as self-exercise) a week for 4 weeks. Both groups repeated an upper limb PNF pattern exercise for 30 min using elastic bands after receiving a manual lymph drainage treatment for 1 hour. Here, subjects in the experimental group performed the PNF exercise with an open-hand grip by putting their hands into the loops of elastic bands and keeping their fingers spread out. Subjects in the control group performed the PNF exercise with a closed-hand grip by holding the loops of elastic bands with their fingers. In both groups, the subjects' edema, ROM, and pain levels were measured before the intervention and 2, 3 and 4 weeks after the intervention. Results: As a result of the experiment, both groups demonstrated edema reductions, ROM increases, and pain reductions in four areas of the upper limbs. Notably, the experimental group exhibited larger ROM increases in flexion, extension, and abduction as well as greater edema and pain reductions than the control group. In particular, the most significant effects were found in the elbow of the four upper limb areas for edema reductions and in extension for ROM increases. Conclusion: The present study indicates that exercise therapy-based approaches using elastic bands in post-mastectomy patients with upper limb lymphedema can have different effects depending on the type of hand grip (open or closed), which is the body's most distal part. Therefore, these approaches should be based on the conditions of the distal parts of the patient's body for their effective applications in clinical practice.

측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구 (Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion)

  • 이소준;허영구
    • 대한물리치료과학회지
    • /
    • 제8권1호
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

슬관절 전치환술 후 만성기 여성 노인의 슬관절 신전근에 근에너지기법이 근력, 관절가동범위, 균형, 보행능력에 미치는 영향 (Effects of Muscle Energy Technique on Knee Extensor Muscle Strength, Knee Range of Motion, Balance, and Walking Ability in Elderly Women during the Chronic Phase after Total Knee Replacement)

  • 송형봉;박근홍
    • 대한정형도수물리치료학회지
    • /
    • 제27권2호
    • /
    • pp.55-67
    • /
    • 2021
  • Background: This study aimed to use the muscle energy technique (MET) with total knee replacement (TKR) during the chronic phase in a clinical setting and confirm its effects on the knee extensor strength and ROM, balance, and walking ability. Methods: A total of 20 female patients who underwent TKR 1~4 years ago were assigned to two groups (Control: Q setting exercise+general physical therapy, n=10; Exp: MET+general physical therapy, n=10). Interventions were performed three times a week for 4 weeks. The strength of the knee extensor was evaluated using an aneroid sphygmomanometer, and ROM was evaluated using degrees at the end range on active knee flexion. The main balance outcomes were evaluated using two standard scale (TSS) and timed up and go (TUG) test, whereas the walking ability was evaluated using the 10 meter walk test (10MWT). Results: Analysis showed that both groups had significant increases in strength, ROM, TSS, TUG, and 10MWT. Differences in all variables were significant between the control and Exp groups at the post-intervention evaluation (p<.05). However, no significant difference was observed in strength and TUG. Conclusion: Results of this study demonstrated that MET would help improve the strength, ROM, balance, and walking ability of patients with chronic TKR who want to enhance their abilities and performance in activities of daily living.

달리기 시 속도 증감에 따른 지지국면에서 발 분절 움직임 분석 (Effects of Running Speed on the Foot Segments Motion at the Stance Phase)

  • 류지선
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.35-42
    • /
    • 2012
  • The aim of the present study was to investigate effect of running speed conditions on the kinematic pattern of the metatarsus, mid-foot, calcaneus. Twenty-two healthy young adults were made to run on treadmill at three different running speeds(normal speed, 9.2; slow speed, 7.4; fast speed, 11.1km/hr.) and the trajectories of the 10 reflective markers for each subject were recorded by an eight-camera motion capture system at 200 Hz. Three-dimensional angles for the foot segment in the support phase during running were calculated according to Euler's technique. Results showed that running speed did not affect the peak of the dorsi/plantar flexion, inversion/eversion, and adduction/abduction or their range of motion for each foot segment. However, when the running speed was fast, significant differences were found in the peak of the plantar flexion, eversion, and adduction and ROM(range of motion) of the dorsi/plantar flexion, inversion/eversion, and adduction/abduction between the foot segments, metatarsus, mid-foot, and calcaneus. It was proposed that the foot segment should be analyzed from a multi-segment system point of view on the basis of anatomical reference during locomotion.

웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석 (Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves)

  • 김은경;김진홍;김유리;홍예지;이강표;전은혜;배준범;김수인;이상이
    • PNF and Movement
    • /
    • 제21권2호
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.