• 제목/요약/키워드: Range of motion(ROM)

검색결과 660건 처리시간 0.027초

다발성 신경병증 및 근병증으로 추정되는 환자의 치료 2례에 대한 증례보고 (The Clinical Study on 2 Cases of Poly neuropathy or Myopathy estimated Patients)

  • 이태호;황희상;장소영;차정호;정기훈;이은용
    • 척추신경추나의학회지
    • /
    • 제2권1호
    • /
    • pp.59-67
    • /
    • 2007
  • Objective : Poly neuropathy is disease that reveals musle relaxation or sensory disorder, and Myopathy is disease that reveals musle weakness, wasting, pain. These diseases occur in the lower or upper limbs. This is the clinical report about Poly neuropathy or Myopathy estimated patients. Method : Patients were treated by acupuncture, herb medicine, bee venom herbal-acupuncture, moxibustion. We evaluated the improvement of symptoms with ROM(Range of Motion) and MCR(Medical Research Council) standard. Result : Symptoms that patients have at admission improved and disappered gradually with oriental medicine therapy. Observing the change of ROM and MCR standard, they indicated us improvement of disease. Conclusion : We achived a desirable result from treatment of peripheral neuropathy or myopathy estimated patients. However, further studies are required to prove the effect of oriental medicine treatment.

  • PDF

Is Pancapsular Release More Effective than Selective Capsular Release for the Treatment of Adhesive Capsulitis?

  • Moon, Nam Hoon;Lee, Seung-Jun;Shin, Won Chul;Lee, Sang Min;Suh, Kuen Tak
    • Clinics in Shoulder and Elbow
    • /
    • 제18권1호
    • /
    • pp.28-35
    • /
    • 2015
  • Background: We assessed the effectiveness of arthroscopic capsular release for the treatment of adhesive capsulitis. Further, we tried to ascertain the clinical benefits, if any, of pancapsular release over selective capsular release, where the two differ by performing or not performing a posterior capsular release, respectively. Methods: Thirty-five consecutive patients with either primary or secondary adhesive capsulitis who failed conservative treatment for more than 6 months were enrolled in the study. A total of 16 patients allocated in group 1 received a pancapsular release that comprises the release of the rotator interval, anteroinferior capsular, and the posterior capsular release, whereas 19 patients in group 2 received a selective capsular release that comprises only the release of the rotator interval release and anteroinferior capsular release. The clinical outcomes, visual analogue scale (VAS) score, Constant score, and range of motion, were assessed preoperative and postoperatively. Results: In both groups, the preoperative VAS score, Constant score, and ROM showed a significant improvement by the 6-month follow-up. We found that the immediate postoperative internal rotation was significantly higher in group 1 than group 2. Despite significant differences seen between the two groups at the initial postoperative period, there were no significant differences in Constant score, VAS score, and the ROM at all the subsequent follow-ups between the two groups. Conclusions: Arthroscopic capsular release for the treatment of adhesive capsulitis is very effective. However, pancapsular release did not show any advantage over selective capsular release in terms of overall clinical outcome.

만성 요통 환자에서의 휴대용 저출력 레이저 치료기의 통증 및 기능 효과 (Efficacy of Portable Low Power Laser Therapy on Pain and Functions in Chronic Low Back Pain)

  • 조연욱;김태희;임오경;이주강;박기덕
    • Clinical Pain
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Objective: A prospective, assessor-blinded, randomized controlled trial was conducted in patients with chronic low back pain to evaluate the efficacy of portable low power laser therapy (LPLT) and the effect when combined with exercise therapy on pain and functions. Method: 60 patients were recruited and 56 patients, excluding 4 dropouts, were randomly allocated to the LPLT group (Group 1: 19 patients), placebo laser therapy with exercise group (Group 2: 18 patients), and LPLT with exercise group (Group 3: 19 patients). Laser therapy and exercise was performed five times a week for 4 weeks. Visual analogue scale (VAS), Schober test, lumbar range of motion (ROM) measures (flexion, extension and lateral flexion), Oswestry Disability index (ODI) were measured at baseline, at 4 weeks after intervention, and at 6 weeks after 2 weeks of no intervention. Results: Statistically significant improvements were noted in all group by time interaction with respect to all outcome parameters (p<0.05). All parameters in each group improved not only in the period of treatment (4 weeks), but also in the final evaluation (6 weeks) 2 weeks after the end of treatment. Post-hoc analysis showed statistically significant difference between the LPLT with exercise group and the other groups in all outcome parameters except for the ODI at 4 weeks and at 6 weeks. Conclusion: Portable LPLT is effective treatment in reducing pain and improving lumbar ROM and with exercise is more effective than laser or exercise monotherapy for the chronic low back pain patients.

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • 제25권1호
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

Applying Focused and Radial Shock Wave for Calcific Tendinitis of the Shoulder : Randomized Controlled Study

  • Kim, Jonggun;Oh, Changmin;Yoo, John;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권3호
    • /
    • pp.356-362
    • /
    • 2022
  • Objective: Extracorporeal shock wave therapy (ESWT) is a nonsurgical treatment alternative to surgery for various musculoskeletal diseases that have traditionally been difficult to treat conservatively, including calcific tendinitis, tennis elbow, and plantar fasciitis. This study evaluated the effect of focused and radial shock wave therapy for calcific tendinitis of the shoulder. Design: Randomized controlled study Methods: Forty participants with calcific tendinitis were randomized into focused shock wave therapy (FSWT, n=20) and radial shock wave therapy (RSWT, n=20) groups. Patients were examined before and one week after treatment. Pain intensity was subjectively assessed using the visual analogue scale and function was assessed using the Constant-Murley score (CMS) and range of motion (ROM). Results: The results showed a significant decrease in pain and significant increase in shoulder mobility and function in both groups. However, FSWT was significantly more effective than RSWT, based on CMS and ROM assessment. Conclusions: Although it is possible to raise the energy intensity of RSWT to increase the depth at which the energy becomes dispersed, higher energy intensity is associated with a greater risk of severe neurovascular damage, and that high-intensity stimulation can cause adverse effects such as pain and petechiae. Therefore, FSWT is considered to be a safe and effective method for treating tendinous lesions while minimizing adverse effects. In conclusion, both FSWT and RSWT can reduce pain and increase mobility and function. FSWT can be considered as an alternative for calcific tendinitis of the shoulder.

경추용 일체형 추간체 유합 보형재의 디자인 변화에 따른 생체역학적 효과 비교 연구 (Comparative Study on Biomechanical Behavior of Various Cervical Stand-Alone Cage Designs)

  • 박광민;정태곤;정승조;이성재
    • 한국정밀공학회지
    • /
    • 제33권11호
    • /
    • pp.943-950
    • /
    • 2016
  • The purpose of this study was to evaluate and compare by finite element analysis the biomechanical performance, in terms of cervical stand-alone cage screw insert angle (Type 3 - 5: 2 Screws) and screw arrangement (Type 6 and 7: 3 Screws / Type 8 and 9: 4 Screws), and the range of motion (ROM) of traditional anterior cervical discectomy of a fusion device (Type 1: Cage / Type 2: Cage + ACP). Our study suggests that the biomechanical behavior of a postoperative cervical spine could indeed be influenced by design features, such as screw angle and number of screws. In particular, ROM and the risk of subsidence were more sensitive during extension about type 5 (Insert Angle $20^{\circ}$). Our study also suggested that the number of screw asymmetries between up and down for type 6 and 7 could result in differences in the risk of screw fracture manifesting in different clinical aspects.

ICF 도구를 적용한 앞십자인대 재건술 환자의 고유수용성신경근촉진법 중재전략의 증례 (A Case Report of a Proprioceptive Neuromuscular Facilitation Intervention Strategy Applied with an ICF Tool in a Patient with Anterior Cruciate Ligament Reconstruction)

  • 송명수;김범룡;김창헌;노현정;강미경
    • PNF and Movement
    • /
    • 제15권1호
    • /
    • pp.1-11
    • /
    • 2017
  • Purpose: The purpose of this study was to use an ICF tool in an intervention for anterior cruciate ligament reconstruction (ACLR) patients to examine and evaluate the patients' functional problems, measure the results of the intervention, and present the process of preparing proprioceptive neuromuscular facilitation (PNF) intervention strategies, thereby contributing to changes in and development of relevant future clinical practices. Methods: A PNF rehabilitation exercise program using an ICF tool was applied to ACLR patients five times per week for four weeks. To measure the resulting changes, the ICF evaluation display, the visual analog scale (VAS), the manual muscle test (MMT), the range of motion (ROM) test, the Lysholm knee score (LKS), and the muscle endurance test (MET) were used. Results: After the intervention was applied to the ACLR patients, improvements were achieved in all the tests: ICF evaluation display, VAS, MMT, ROM, LKS, and MET. Conclusion: Utilizing the ICF tool, this study identified functional problems of ACLR patients. When the intervention was applied, physical functions improved, and structural damage was reduced, leading to enhanced levels of functional activities such as postural changes, posture maintenance, gait, movements, and movements between different places. The patients were able to complete the teacher training, which was their goal.

Effects of Electrical Muscle Stimulation for Preventing Deltoid Muscle Atrophy after Rotator Cuff Repair: Preliminary Results of a Prospective, Randomized, Single-blind Trial

  • Lee, Goo Joo;Cho, Hangyeol;Ahn, Byung-Hyun;Jeong, Ho-Seung
    • Clinics in Shoulder and Elbow
    • /
    • 제22권4호
    • /
    • pp.195-202
    • /
    • 2019
  • Background: This study investigates the effects of neuromuscular electrical stimulation (NMES) in preventing deltoid atrophy during the first 12 weeks after arthroscopic rotator cuff repair. Methods: Eighteen patients undergoing arthroscopic repair of a medium-sized rotator cuff tear by a single surgeon, were randomized into two groups: NMES and transcutaneous electrical nerve stimulation (TENS). Each group used the respective device for 6 weeks after surgery. Pain was measured at baseline, 6, and 12 weeks postoperatively, using the visual analogue scale (VAS); range of motion (ROM), abduction strength and functional scores were measured at baseline and 12 weeks postoperatively. Deltoid thickness and cross-sectional areas were measured using magnetic resonance imaging at 12 weeks postoperatively. Results: At 12 weeks post-surgery, no statistically significant difference was observed between the NMES and TENS groups in the pain VAS, the Disabilities of the Arm, Shoulder and Hand score, ROM, and abduction strength. Postoperative decrease in the thickness of the anterior, middle, and posterior deltoid, at the level just below the coracoid, was -2.5%, -0.7%, and -6.8%, respectively, in the NMES group, and -14.0%, -2.6%, and -8.2%, respectively, in the TENS group (p=0.016, p=0.677, and p=0.791, respectively). At the level of the inferior glenoid tubercle, postoperative decrease in area of the deltoid was -5.4% in the NMES group and -14.0% in the TENS group, which was significantly different (p=0.045). Conclusions: NMES has the potential for reducing deltoid atrophy after arthroscopic rotator cuff repair, suggesting that NMES might help minimize postoperative atrophy after various shoulder surgeries.

경도 지적장애 자동차제조업 근로자의 근골격계 위험 요인 조사 -목과 허리 부위 중점으로- (Risk Factors of Musculoskeletal System in Automobile Manufacturing Workers with Mlid Intellectual Disabilities: Focus on Neck and Lower Back Regions)

  • 황영인;박두진
    • PNF and Movement
    • /
    • 제22권1호
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: The aim of this study was to investigate and compare the risk factors focusing on the neck and lower back between general workers (GW) and mild intellectual disability workers (MIDW) in the automobile manufacturing industry. Methods: A total of 32 participants were required for this study design to achieve 80% power, 0.9 effect size, and an alpha level of 0.05. Each group consisted of 16 subjects, including GW and MIDW. Pain levels in the neck and lower back were measured for all participants using the visual analog scale (VAS). A dual digital inclinometer was used to measure the range of motion (ROM) in the neck and lower back three times, and the average was used for analysis. The independent t-test was used to compare between the wo groups. Cohen's d effect analysis was employed to determine the effect size. The significant level was set at 0.05. Results: In the MIDW, neck pain was significantly higher, and left cervical flexion was significantly decreased compared with the GW. There was no significant difference in lower back pain between the MIDW and GW. However, both lumbar flexion and extension, as well as lateral flexion, were significantly reduced in the MIDW compared with the GW. Conclusion: This study reveals that MIDW working in the automobile manufacturing industry have a greater risk of neck pain, limitation in left cervical flexion, and overall restriction in the ROM of the lower back compared with GW.

보상작용 억제와 피드백을 제공한 가상현실 치료가 만성 뇌졸중 편마비 환자의 상지기능에 미치는 영향 (The Effects of Virtual Reality Therapy With Compensation Inhibition and Feedback on Upper Extremity Function in Hemiplegic Patients With Chronic Stroke)

  • 천승철;장기연
    • 한국전문물리치료학회지
    • /
    • 제18권2호
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study was to investigate the effects of virtual reality (VR) therapy with compensation inhibition and feedback (CIF) on upper extremity function in chronic stroke patients. Seven chronic stroke patients participated in this study, which was a randomized controlled trial with a crossover design. Self upper extremity exercise, conservative VR therapy, and VR therapy with CIF were performed for one hour per session, 5 times per week, over a 3 week period. The main outcome measures involved range of motion (ROM) including shoulder, elbow, and wrist joints, a Manual Function Test (MFT), and a Motor Activity Log (MAL). Data were calculated as posttest and pretest changes in every session and were analyzed using Friedman and Wilcoxon signed-rank tests at p<.05. The results were as follows: 1) Statistically significant increase in ROM measurements of shoulder and elbow joints were seen with VR therapy with CIF compared to VR therapy and self upper extremity exercise (p<.05), whereas no significant increasing was noted for the wrist joint (p>.05). 2) Statistically significant increase in the MFT was seen with VR therapy with CIF compared with VR therapy and self upper extremity exercise (p<.05). 3) VR therapy with CIF also resulted in statistically significant increase in both activity of use (AOU) (p<.05) and quality of movement (QOM) (p<.05) on the MAL test when compared with VR therapy and self upper extremity exercise, respectively. In conclusion, VR therapy with CIF was more effective than conservative VR therapy and self upper extremity exercise in improving the upper extremity function in hemiplegic patients with chronic stroke.