• 제목/요약/키워드: Range Safety

검색결과 3,015건 처리시간 0.027초

다단 변속기의 강도설계 검증 (Strength Design Evaluation of the Multi-range Transmission)

  • 공민규;송철기;김영덕
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.12-17
    • /
    • 2011
  • Gears are useful for power transmission due to excellent power transmission performance, low cost, and compactness. In addition, gears have constant speed ratio, compact structure, and excellent efficiency. In order to transmit higher power, the new multi-range transmission requires gears which have greater strength than the existing transmission. This study evaluates stability and durability through gear analysis of the multi-range transmission in commercial vehicles using ROMAX-DESIGNER program. Also, strength design evaluation is carried out by the analysis results which are compared with gear strength theory of AGMA standard. Bending stress and contact stress on gears are lower than their allowable stresses. Therefore, we can evaluate the safety of the gear strength design in multi-range transmission.

공정안전향상을 위한 Safety Integrity Level의 적용 방향 (Towards the Application of Safety Integrity Level for Improving Process Safety)

  • 권혁면;박희철;천영우;박진형
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

초고압 시스템의 안전성 확보에 대한 연구 (A Study of Safety Acquirement for an Assessment of Ultra High Pressure System)

  • 이기천;김형의;김재훈
    • 한국안전학회지
    • /
    • 제25권5호
    • /
    • pp.7-14
    • /
    • 2010
  • Ultra high pressure system, which can be generally increased over 1,000bar, needs to have sealing mechanism to protect leakage and selection of the materials used in the intensifier. Components such as pressure vessel, hydraulic hose assembly, accumulator, hydraulic cylinder, hydraulic valve, pipe, etc., are tested under the impulse-pressure conditions. Components need to be tested under 1.5 to 3 times of rated pressure to check the tolerance even though rated pressure range of these components are not ultra high pressure. So, the ultra high pressure system needs to be equiped to test components. In this study, safety assessments of ultra high pressure system which are using failure analysis of components, changing the types of the control system, and finite element analysis with static condition, are investigated.

노화된 천연고무의 유전손실에 관한 전기안전특성 (Properties of Electric Sofety for Dielectric Loss of Aging Natural Rubber.)

  • 이성일;권호영
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.5-12
    • /
    • 1991
  • The dielectric properties of natural rubbers for electric safety are very important to investigate the molecular structure. The electric safety characteristics of the dielectric absorption in aging vulcanized natural rubber were studied in the range of frequency from 1$\times$10$^3$[Hz]to 3.2$\times$10$^3$[Hz]l at the temperature of 23[$^{\circ}C$]. As the results, it has been confirmed that in the case of aging natural rubber of above 2 phr the specimens exhibit two kinds of dielectric losses due to the dipole polarization by impurities and sulfurs, and of raw rubber exhibit the kind of losses due to the dipole polarization. Rurthermore, dielectric loss maximum tansspectrum in high freguency region for electric safety, which removed to the low freguency according to increasing sulfur, depends greatly on sulfur.

  • PDF

화학사고의 일차 대응을 위한 피해영향범위 산정 개선 방안 (Improvement of Damage Range Calculation for First Response to Chemical Accidents)

  • 이덕재;안재현;송창근
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.59-65
    • /
    • 2017
  • Calculation of the damage impact of chemical accidents is an important element in site, and the initial isolation distance and the protective action distances are significant factors in coping the chemical accident. In this study, three major cities that represent each Province were selected, and the safety distances were calculated considering regional climate conditions. The results were compared with the prescribed values in Emergency Response Guidebook. It is concluded that the regional meteorological conditions such as temperature, vapour pressure, relative humidity, wind speed, and cloud cover should be reflected in estimating the initial isolation distance and the protective action distance.

고강도 콘크리트를 적용한 얇은 RC 판부재의 정적 강도 안전성 평가 (Structural Safety Evaluation for Static Strength of Thin Plate RC Member with High Strength Concrete)

  • 황훈희;박성용
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.69-75
    • /
    • 2017
  • Structural safety evaluation for static strength of thin plate RC member with high strength concrete is conducted in this study. Static strengths were predicted and compared with the experimental values. Predicted values were calculated by the evaluation formula based on the punching shear behavior and the yield line theory which can appear in the plate members. Static load tests were carried out for the specimens with high strength concrete and the test results were compared with the required performance in design. The comparison results show that the specimens with high strength concrete have sufficient structural safety for flexural and punching shear performance required in design. High strength concrete specimens exhibited excellent strength despite their small thickness. The range of concrete strengths applied in this study was about 60 MPa to 100 MPa.

타워크레인의 기울어짐 측정 시스템 개발 (The Development of the Slope Monitoring System(SMS) of the Tower Crane)

  • 신운철;홍용수
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.60-64
    • /
    • 2010
  • The purpose of this study if to prevent dangerous accident of the overthrow of the tower crane in summer's hurricane. We develop the SMS in order to give automatic alarm system to operator within the dangerous range and to give a information of the exactly slope in the real time. The slope value of the tower crane is compose of direction, pitch by the front and rear, roll by the right and left and synthesis by the its pitch and roll. Especially, the synthesis eliminate the effect of the wall tie or wire bracing. So, this value should correctly indicate the actual slope. In this study, more applying field test should be applied with the SMS. In the future, a more measurement device can be applied to, and be able to feed more alarm criteria for the review of the risk in the field.

저압용 나전선의 단락조건에 의한 단면 분석 (The Cross Section Analysis CSA based on the Short Circuit Conditions of the Low Voltage Bare Wires)

  • 송길목;김동욱;김동우;김영석;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2094-2096
    • /
    • 2005
  • In this paper, we studied the cross section analysis based on the short circuit conditions of the low voltage bare wires. The copper wires prepared for the experiment were 1.2mm 1.6mm and 2.0mm in diameter. Through the cross section analysis(CSA), it was confirmed that the dendrite structure grew at the angle of about $40^{\circ}$ or $60^{\circ}$ when the fusing current was applied to the wires. The larger the fusing current is, the more decreased the growth angle of the dendrite structure is. It was confirmed that the dendrite structure was arranged like the columnar structure. In this paper, the characteristics analysis of short circuit was carried out in the range of transient duration.

  • PDF

살충제 성분이 함유된 농약제품의 에어로졸 분사에 따른 금속 및 식물의 부식 영향에 관한 연구 (A Study on the Influence of Corrosion of Metals and Plants through Aerosol Type Spraying of Agricultural Pesticide Products Containing Insecticide Ingredients)

  • 김정훈
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.8-14
    • /
    • 2018
  • Recently, serious problems occurred such as insecticide eggs, sanitary pads with carcinogens, radon(Rn) emitting beds in domestic. It had not been establishing the inspection system to evaluate safety and human harmfulness before occurring real accidents. This research was conducted to test preliminary experimental inspection for consideration of safety insensibility. The influence of corrosion of metals and plants was studied through aerosol type spraying of agricultural pesticide products coming into the market. These products contain primary three insecticide ingredients(Flufenoxuron, Etoxazole, Fipronil) in recent accidents. Visual examination, SEM-EDS and optical microscope were used for the analysis for corrosion effect. Results show that a lot of ingredients contain in the crop protection products, and various type of corrosion exist in the surface of metals and plants. Therefore, it is necessary to provide health warning and accurate range of use for crop protection products containing insecticide ingredients.

Defining a "Safe System of Work"

  • Caponecchia, C.;Wyatt, A.
    • Safety and Health at Work
    • /
    • 제12권4호
    • /
    • pp.421-423
    • /
    • 2021
  • Providing a "safe system of work" is the essence of the general duties that employers have to their employees under workplace health and safety regulations. Despite this, consistent and appropriate definition of what constitutes a safe system of work is almost non-existent. Available definitions tend to confuse a safe system of work with management practices intended to bring about a safe system, or conflate the broad system suggested in general duties clauses with procedures or work methods that are focused on particular hazards or tasks. This article develops a definition of safe systems of work which recognises the broad scope of the concept and includes psychological health and return to work processes. This definition can be used by a range of stakeholders to better communicate the scope of occupational health and safety duties and more consistently assess whether a safe system has been provided both before and after incidents occur.