• Title/Summary/Keyword: Range Of Motion

Search Result 3,084, Processing Time 0.028 seconds

The Effect of Taping on the Range of Motion and Proprioception at the Ankle Joint (테이핑이 발목의 관절가동범위와 고유수용성감각에 미치는 영향)

  • Kim, Chang-In;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.43-52
    • /
    • 2001
  • This study was designed to determine the effect of ankle taping and short period of walking on the treadmill on the range of motion (ROM) and proprioception at the ankle joint. Twenty healthy male subjects (mean age=24.2 yr) participated in this study. Goniometry and videotape replaying method were used to measure the ankle ROM. Passive sagittal and frontal plane motions were measured. The difference in degree between the stimulus point and the reproduced point was defined as an angular error. The measurements were performed at four different phases: pre-taping (PRT), post-taping immediately (POT), post-5 minute walking with taping (P5M), and post-10 minute walking with taping (P10M). The ankle of dominant limb was taped by a certified athletic trainer using a closed basket weave technique. Participants walked on the treadmill at 2.5 mph. The results showed that the mean of the sagittal plane motion at PRT, POT, P5M, and P10M was 53.0, 30.5, 36.2, and 40.2 degrees, respectively. The frontal plane motion at PRT, POT, P5M, and P10M was 33.6, 13.9, 15.7, and 18.6 degrees, respectively. The angular error at PRT, POT, P5M, and P10M was 5.5, 1.6, 1.8, and 1.9 degrees, respectively. After 10 minutes of walking, the sagittal plane motion and frontal plane motion was increased by 9.7 and 4.7 degrees compared with POT, respectively. The proprioception was significantly improved after the application of ankle taping. Both the restriction of frontal plane motion and proprioception improvement at the ankle joint may contribute to ankle stability during walking.

  • PDF

A Study on an Image Stabilization for Car Vision System (차량용 비전 시스템을 위한 영상 안정화에 관한 연구)

  • Lew, Sheen;Lee, Wan-Joo;Kang, Hyun-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.957-964
    • /
    • 2011
  • The image stabilization is the procedure of stabilizing the blurred image with image processing method. Due to easy detection of global motion, PA(Projection algorithm) based on digital image stabilization has been studied by many researchers. PA has the advantage of easy implementation and low complexity, but in the case of serious rotational motion the accuracy of the algorithm will be cut down because of its fixed exploring range, and, on the other hand, if extending the exploring range, the block for detecting motion will become small, then we cannot detect correct global motion. In this paper, to overcome the drawback of conventional PA, an Iterative Projection Algorithm (IPA) is proposed, which improved the correctness of global motion by detecting global motion with detecting block which is appropriate to different extent of motion. With IPA, in the case of processing 1000 continual frames shot in automobile, compared with conventional algorithm and other detecting range, the results of PSNR is improved 6.8% at least, and 28.9% at the most.

The Effects of Auricular Electroacustimulation and Transcutaneous Electrical Nerve Stimulation on Postoperative Pain Control in Total Knee Replacement Patients (외이전기경혈자극과 경피전기신경자극이 슬관절 전 치환슬 환자의 수술 후 통증조절에 미치는 효과)

  • Kim, Tae-Youl;Hwang, Tae-Yeun;Huh, Choon-Bok
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.1
    • /
    • pp.145-163
    • /
    • 1994
  • This study was done to determine differences in effect of postoperative pain control in patients receiving auricular electroacustimulation vs transcutaneous electrical nerve stimualtion following total knee replacement surgery. Thirty-one cases referred to physical therapy department after treated by total knee replacement surgery by orthopedic surgery department at the Pohang St. Mary's Hospital from January 1993 through June 1994. Of 31 total knee replacement cases, 13 cases were auricular electroacustimulation group, 11 cases were transcutaneous electrical nerve stimulation group, and 7 cases were control group. The results of the study summerized are as follows: Thirty-one total knee replacement cases(male in 12 cases, female in 19 cases), ranging in age from 34 to 61 years(mean${\pm}$SD=49.90 7.56) with diagnoses of degenerative arthritis(20 cases), rheumatoid arthritis(9 cases), and other(2 cases). In auricular electroacustimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In transcutaneous electrical nerve stimulation group, there was a significant change of pain intensity, unpleasantness, and active range of motion after treatment(p<0.01). In control group, did not show significant pre-posttreatment differences in pain intensity, unpleasantness, active range of motion(p>0.05). The mean change in pain intensity and unpleasantness, active range of motion from pretreatment baseline for the 3 groups. Auricular electroacustimulation group showed the large magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. Transcutaneous electrical nerve stimulation group showed small magnitude of increase in pain intensity and unpleasantness, active range of motion when compared to its own pretreatment cycle. No significant changes were observed in control group. Highly significant differences in pain intensity, unpleasantness, and active rage of motion were found using an ANOVA measures between treatment groups and control group(p<0.01). The squares correlation coefficients of pain and function measures pretreatment-posttreatment differences for each group. In treatment group, there was significant correlation between pain scale and function(p<0.001). In control group, there was no correlation between the pain scale and function (p>0.05). The continuous study is needd for many interesting issues of auricular electroacustimulation in new future.

  • PDF

The Changes of Range of Motion of Lumbar Region and Muscle Activities of Lumbar Extensor During Trunk Motions Between Subjects With Low Back Pain and Healthy Subjects (만성요통환자와 정상인의 체간 운동시 요추 신전근의 근활성도와 관절운동범위의 변화)

  • Kim, Tae-Ho
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.61-69
    • /
    • 2006
  • The purpose of this study was to compare the electromyography (EMG) activities of the lumbar extensor muscles during motion of trunk flexion-extension and compare range of motion (ROM) with a 3-dimensional motion analysis system of the lumbar region between subjects with chronic low back pain (CLBP) and healthy subjects during the trunk flexion-extension, trunk rotation and trunk lateral flexion cycle. Thirty CLBP subjects and thirty healthy subjects were included. We measured the root mean square (RMS) value of the lumbar extensor muscles from resting, standing, lumbar flexion and return position. The RMS ratio was normalized from maximal EMG activity of the lumbar extensor muscles during trunk motion. The results of this study showed that the RMS ratio of the lumbar extensor was significantly higher in CLBP subjects than healthy subjects during all of trunk motion (p<.05). The ratio of the highest RMS value during flexion and extension was higher in CLBP subjects than in healthy subjects (p<.05). The ROM of the lumbar region was significantly lower in CLBP subjects than healthy subjects during trunk flexion-extension, trunk rotation and lateral flexion cycle. The relationship between the RMS ratio for full lumbar flexion and the ROM of lumbar flexion was not correlated significantly. CLBP subjects have both decreased ROM of the lumbar region and higher muscle activities of the lumbar extensor muscle than healthy subjects.

  • PDF

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

Numerical Study on the Motion Characteristics of a Freely Falling Two-Dimensional Circular Cylinder in a Channel (채널 내 자유 낙하하는 2차원 원형 실린더의 운동 특성에 관한 수치적 연구)

  • Jeong, Hae-Kwon;Yoon, Hyun-Sik;Ha, Man-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.495-505
    • /
    • 2009
  • A two-dimensional circular cylinder freely falling in a channel has been simulated by using immersed boundary - lattice Boltzmann method (IB-LBM) in order to analyze the characteristics of motion originated by the interaction between the fluid flow and the cylinder. The wide range of the solid/fluid density ratio has been considered to identify the effect of the solid/fluid density ratio on the motion characteristics such as the falling time, the transverse force and the trajectory in the streamwise and transverse directions. In addition, the effect of the gap between the cylinder and the wall on the motion of a two-dimensional freely falling circular cylinder has been revealed by taking into account a various range of the gap size. As the cylinder is close to the wall at the initial dropping position, vortex shedding in the wake occurs early since the shear flow formed in the spacing between the cylinder and the wall drives flow instabilities from the initial stage of freely falling. In order to consider the characteristics of transverse motion of the cylinder in the initial stage of freely falling, quantitative information about the cylinder motion variables such as the transverse force, trajectory and settling time has been investigate.

Simple analytical method for predicting the sloshing motion in a rectangular pool

  • Park, Won Man;Choi, Dae Kyung;Kim, Kyungsoo;Son, Sung Man;Oh, Se Hong;Lee, Kang Hee;Kang, Heung Seok;Choi, Choengryul
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.947-955
    • /
    • 2020
  • Predicting the sloshing motion of a coolant during a seismic assessment of a rectangular spent fuel pool is of critical concern. Linear theory, which provides a simple analytical method, has been used to predict the sloshing motion in rectangular pools and tanks. However, this theory is not suitable for the high-frequency excitation problem. In this study, the authors developed a simple analytical method for predicting the sloshing motion in a rectangular pool for a wide range of excitation frequencies. The correlation among the linear theory parameters, influencing on excitation and convective waves, and the excitation frequency is investigated. Sloshing waves in a rectangular pool with several liquid heights are predicted using the original linear theory, a modified linear theory and computational fluid dynamics analysis. The results demonstrate that the developed method can predict sloshing motion over a wide range of excitation frequencies. However, the developed method has the limitations of linear solutions since it neglects the nonlinear features of sloshing motion. Despite these limitations, the authors believe that the developed method can be useful as a simple analytical method for predicting the sloshing motion in a rectangular pool under various external excitations.

Analysis of Gait Parameters According to the Clinical Features of Parkinson's Disease Using 3-D Motion Analysis System with Electrogoniometer (3차원 전기측각 보행분석기를 이용한 파킨슨씨병 환자의 임상 양상에 따른 보행 분석)

  • Baek, Hye-Jin;Yoon, Joon-Shik;Kim, Sei-Joo;Lee, Gyu-Ho;Koh, Seong-Beom
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Background: To investigate the differences of locomotor dynamics between Parkinson's disease (PD) patients with tremor dominant symptom and patients with postural instability dominant symptom. Methods: 66 subjects with PD were classified into two subgroups, tremor-dominant group and postural instability and gait disorder group by Unified Parkinson's disease rating scale (UPDRS). The spatial, temporal and electrodynamic gait parameters were recorded automatically using computerized 3-D motion analysis system with electrogoniometer. Results: There was no significant difference in cadence, pelvic tilt range, hip flexion range, knee flexion range and ankle dorsiflexion range. Postural instability and gait disorder group showed decreased gait velocity, short stride length, decreased range of motion in pelvic obliquity, pelvic rotation and ankle plantar flexion. Conclusions: There was meaningful difference in locomotor dynamics between Parkinson's disease(PD) patients with tremor dominant symptom and patients with postural instability dominant symptom.

  • PDF

Shape optimization of blended-wing-body underwater glider by using gliding range as the optimization target

  • Sun, Chunya;Song, Baowei;Wang, Peng;Wang, Xinjing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.693-704
    • /
    • 2017
  • Blended-Wing-Body Underwater Glider (BWBUG), which has excellent hydrodynamic performance, is a new kind of underwater glider in recent years. In the shape optimization of BWBUG, the lift to drag ratio is often used as the optimization target. However this results in lose of internal space. In this paper, the energy reserve is defined as the direct proportional function of the internal space of BWBUG. A motion model, which relates gliding range to steady gliding motion parameters as well as energy consumption, is established by analyzing the steady-state gliding motion. The maximum gliding range is used as the optimization target instead of the lift to drag ratio to optimizing the shape of BWBUG. The result of optimization shows that the maximum gliding range of initial design is increased by 32.1% though an Efficient Global Optimization (EGO) process.

The Effects of Group Movement Training on Psychophysiological Variables and the Range of Motion in the Institutionalized Elderly (집단동작훈련이 시설노인의 생리, 심리적 변수 및 관절운동범위에 미치는 영향)

  • Suh, Boo-Deuk
    • Research in Community and Public Health Nursing
    • /
    • v.20 no.4
    • /
    • pp.403-411
    • /
    • 2009
  • Purpose: The purpose of this study is to explore the effects of a group movement exercise program on psychophysiological variables in the institutionalized elderly. Methods: This research adopted the non-equivalent control group pretest-posttest design. Twenty elders were selected as an experimental group, whereas twenty-two elders were as a control group. The group movement program consisted of 35 minutes of dance and three days a week for eight weeks. Resting systolic blood pressure, diastolic blood pressure and heart rate were measured in a relaxed sitting position. The range of flexion and extension of joint was measured with a gonimeter. Life satisfaction and self-efficacy were measured by self-report. Data were analyzed through $x^2$-test, t-test and ANCOVA using SPSS/WIN program. Results: The results were as follows: Resting systolic blood pressure, diastolic blood pressure and resting heart rate decreased significantly by the group movement training. The range of flexion and extension of the shoulder and hip joints increased significantly. The scores of life satisfaction and self-efficacy increased remarkably by the group movement. Conclusion: The results suggest that group movement training can be an effective intervention to improve psychophysiological variables and the range of motion for the institutionalized elderly.

  • PDF