• 제목/요약/키워드: Range Extender

검색결과 16건 처리시간 0.024초

Simulator for Monitoring the Operations of Range Extender Electric Vehicles

  • Chun, Tae-Won;Tran, Quang-Vinh;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.424-429
    • /
    • 2011
  • In this paper, the simulator of an on-line monitoring system for the range extender electric vehicle has been developed. The messages from the four control modules, the air pressure and fuel level sensors data, and the on/off switching states of 31 indicator lamps can be received through the control area network (CAN), and displayed on the graphic panel. The simulator was designed using the four DSP boards, variable resistors, and toggle switches instead of the four control modules, sensors, and switching state of indicator lamps on an actual series hybrid electric vehicle (SHEV) bus, respectively. The performance of the monitoring technologies was verified with the simulator at the laboratory, and then it was tested on an actual SHEV bus. The simulator is very useful at the initial development of the monitoring system at the hybrid-type or electrical vehicles.

전산유체해석을 통한 RE엔진 냉각수 코어의 성능 개발 (Performance Development of Coolant Core for Range Extender Engine Using CFD Simulation)

  • 김창수;박성영
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2075-2080
    • /
    • 2013
  • 본 논문에서는 RE엔진에 적용하기 위한 냉각수 코어를 CFD 기술을 활용하여 개발하였다. 개선 모델은 배기밸브 주위와 사이의 온도를 저감하기 위한 냉각수 우회부를 추가하였다. 2번 실린더 블록 주위와 배기밸브 사이의 유량이 증가하였기 때문에, 베이스 모델대비 개선 모델의 유량 정체가 개선되었다. 결과적으로, 배기밸브 주위에서의 열전달이 향상되고, 전 유량 구간에서 기존 모델 대비 약 5%의 압력 강하량 저감 효과를 보이는 개선 모델을 얻을 수 있었다. 압력 강하량의 저감은 상응하는 냉각수 펌프의 부하를 저감하고 연비에 긍정적 영향을 미칠 것으로 판단된다.

전산유체해석을 통한 RE엔진 흡기포트의 개발 (Development of Intake Port for Range Extender Engine Using CFD Simulation)

  • 김창수;박성영
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2575-2580
    • /
    • 2013
  • 본 논문에서는 RE엔진에 적용하기위한 흡기포트를 CFD 기술을 활용하여 개발하였다. 3차원 모델링을 진행하고 전산유체해석을 진행하였으며, 계산된 유량계수와 스월계수를 실험결과와 비교 분석하였다. 흡기포트의 convex 및 concave부 곡률을 최적화하여 Recirculation의 발생과 유동저항을 저감하였다. 결과적으로, 계산된 평균 유량계수는 0.383이고, 평균 스월수는 1.544로 일반적인 2밸브 엔진 시스템의 평균성능에 상회하는 우수한 성능을 나타내었다.

레인지 익스텐더 전기자동차 엔진용 저가형 2단속도 고정밀 운전제어시스템 개발 (Development of Low-Cost, Double-Speed, High-Precision Operation Control System for Range Extender Engine)

  • 함윤영;이정준
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.529-535
    • /
    • 2018
  • 레인지 익스텐더 전기자동차는 소형의 발전용 엔진이 가장 효율이 좋은 특정 운전영역에서 기동하여 배터리를 충전시키며 주행거리를 연장하는 메커니즘으로 주행한다. 본 연구에서는 저가이면서 제어 로직이 간단한 시스템을 개발하기 위하여 기존 쓰로틀바디시스템을 대체하는 스텝모터방식 흡입공기량 공급시스템을 개발하여 기존 base 엔진에 적용하고, 흡입공기량 증대를 통한 성능 개선을 위해 흡 배기다기관의 길이 변경 효과를 실험적으로 살펴보았다. 실험결과, 하나의 스텝모터로 작동하는 Type B의 흡입공기량조절장치가 Type A보다 전 운전영역에서 성능이 높았으나 유동저항의 증가로 base 엔진보다는 성능이 낮았다. 이를 개선하기 위해 흡기매니폴드에 140mm 어댑터를 장착한 경우와 새로 설계된 70mm 길이의 배기 매니폴드를 적용한 경우 2200rpm과 4300rpm 두 속도조건에서 엔진성능이 향상됨을 확인할 수 있었다. 최적 설계된 엔진을 대상으로 레인지 익스텐더 전기자동차에 적용 가능하도록 발전기 부하를 연결하여 2단 속도로 고정밀 운전제어를 구현하였으며 그 결과, 1단 2200rpm과 2단 4300rpm 운전조건에서 ${\pm}2.5%$ 이내의 속도변화율을 나타내었고, 1단 속도에서 2단 속도로 상승 시 610rpm/s의 목표속도 추종성 결과를 얻었다.

폴리(테트라메틸렌 글리콜)(PTMG)/폴리카프로락톤)(PCL) 폴리올의 혼합비가 수분산계 폴리우레탄의 물성에 미치는 영향 (Effects of Physical Properties on Waterborne Polyurethane with Poly(tetramethylene glycol) (PTMG) and Polycaprolactone (PCL) Contents)

  • 양윤규;곽노석;황택성
    • 폴리머
    • /
    • 제29권1호
    • /
    • pp.81-86
    • /
    • 2005
  • 본 연구에서는 폴리(테트라메틸렌 글리콜)(PTMG), 폴리카프로락톤(PCL) 및 isophron diisocyanate(IPDI)와 dimethylol propionic acid(DMPA)를 이용하여 물에 분산이 가능한 수분산계 폴리우레탄을 제조하였다. 또한, 사슬연장제의 함량을 변화시키면서 입도분석과 기계적 물성 등을 시험하였다. 유화된 폴리우레탄의 입경은 50~200 nm이었으며, PCL과 사슬연장제의 함량이 많을수록 작아졌으며, $T_g$는 -70~-45 ${\circ}C$ 범위이고 사슬연장제의 함량이 증가함에 따라 $T_g$는 다소 상승하였다. PTMG와 PCL을 혼합하여 합성한 폴리우레탄의 $T_g$는 이들을 각각 사용하여 합성한 $T_g$와 비슷하게 나타났다. 인장강도는 PCL과 사슬연장제의 함량이 증가할수록 높아졌으며 신율은 낮아졌다. 폴리올을 혼합하였을 경우에는 단독으로 합성한 것보다 전반적으로 기계적 물성이 저하되는 것을 확인하였다.

Influence of Osmolality of Complete Semen Extender on Motion Characteristics of Frozen-thawed Ram Spermatozoa

  • Joshi, Anil;Mathur, A.K.;Naqvi, S.M.K.;Mittal, J.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권12호
    • /
    • pp.1716-1721
    • /
    • 2006
  • The present study was conducted to observe the effect of osmolality of glycerolated TEST-yolk glycerol extenders on post-thawing sperm kinematics of ram spermatozoa of the native Malpura breed maintained in a semi-arid tropical environment. Good quality semen obtained from adult rams was pooled, split and diluted to 1,000 million spermatozoa per ml in complete TEST-yolk-glycerol extenders of 900, 1,200, 1,500 and 1,800 mOsm/kg osmolality. Diluted semen samples were loaded in 0.25 ml straws and cooled down to $-125^{\circ}C$ freezing temperature at the rate of $-25^{\circ}C$ per minute under controlled conditions before plunging into liquid nitrogen for storage. The thawing of straws was performed at $50^{\circ}C$ in a water bath for 10 seconds and sperm kinematics of the frozen-thawed spermatozoa were assessed by a computer-assisted sperm analysis technique. Osmolality of diluent had no significant effect on post-thawing % motility, % rapid, % medium and % slow moving frozen-thawed spermatozoa but significantly (p< 0.05) affected the % linearity and % straightness. The post-thawing % motility and % rapid motile spermatozoa were highest in samples extended in diluent of 1,500 mOsm/kg osmolality and lowest in 900 mOsm/kg. The curvilinear velocity of spermatozoa was significantly (p<0.05) higher for samples extended in 1,800 mOsm/kg, compared to those in 900 and 1,200 mOsm/kg, but the effect was not significantly different to those extended in diluent of 1,500 mOsm/kg osmolality. The study indicated that ram spermatozoa could tolerate a wide osmolality range for dilution in the complete TEST-yolk-glycerol extender for their cryosurvival. The highest recovery of motile spermatozoa following thawing was achieved in samples extended in the TEST-yolk-glycerol diluent of 1,500 mOsm/kg osmolality.

라즈베리파이를 이용한 이동형 와이파이 확장기 구현 (Implementation of portable WiFi extender using Raspberry Pi)

  • 정복래
    • 산업융합연구
    • /
    • 제20권1호
    • /
    • pp.63-68
    • /
    • 2022
  • 학교와 회사 건물의 복도 천장에는 보통 공용으로 사용할 수 있는 와이파이 엑세스 포인트(WiFi Access Point)가 설치되어 있다. 철문과 같이 신호 감쇠가 큰 재료로 구성된 출입문을 통해 와이파이 신호가 들어오는 건물 구조일 경우 문을 닫으면 인터넷 연결이 자주 끊기거나 실패하게 된다. 본 연구는 이를 해결하기 위해 라즈베리파이(Raspberry Pi)와 보조 배터리를 이용하여 경제적이고 이동 가능한 와이파이 확장기를 구현한다. 시중에 판매되는 와이파이 확장기는 전원 플러그가 위치한 곳에만 설치해야 하는 장소의 제약이 있고 스마트폰 핫스팟 기능에 기반한 와이파이 확장은 일부 고급형 기종에서만 가능하다는 단점이 있다. 그러나 제안 시스템은 출입문 안쪽에서 와이파이 수신 신호가 가장 좋은 위치에서 설치 가능하므로 원신호의 손상 가능성을 최소화하면서 와이파이 범위를 확장할 수 있다. 그 결과 출입문이 닫힌 환경에서 사무실내 전파 음영을 해소하고, 웹브라우징과 720p 해상도의 동영상 스트리밍 시청이 가능함을 실험을 통해 확인한다.

Study on Cryopreservation of Epididymal and Ejaculated Semen in Korean Native Canine and Subsequent Pregnancy Rate after Artificial Insemination

  • Kim S. K.;Lee B. K.;Kim M. K.
    • Reproductive and Developmental Biology
    • /
    • 제28권3호
    • /
    • pp.155-159
    • /
    • 2004
  • This study was carried out to investigate the general characteristics and viability of sperm after freezing and thawing and the pregnancy rates after artificial insemination with thawed semen. The rates of viable sperm after slow and rapid freezing were 87.4±3.85% and 70.8±4.45%, respectively which were significantly lower than that of fresh semen control (91.7±3.45%). The mean concentration of epididymal sperm after dilution in 1.0 ml saline and. 3.0 ml extender in a various concentrations of cryoprotectants was 124.5±48.3 x 10/sup 6/ (range of 45 x 10/sup 6/ to 280 X 10/sup 6/ /ml). There was a significant difference not in the percentage of acrosome-reacted sperm, but in the percentage of capacitated sperm, between fresh and frozen-thawed epididymal semen. When frozen-thawed after diluting with tris-buffer extender containing glycerol, DMSO and ethylene glycol with concentration of 2 to 6%, the rates of epididymal sperm exposed to different cryoprotectants ranged from 14.4±4.7% to 20.7±5.8%, 17.8±5.2% to 36.5±4.9%, and 14.4±4.6% to 18.5±5.3%, respectively which were lower compare to fresh semen control. The pregnancy rate after artificial insemination with frozen semen was 70.6%, whereas that with fresh semen was 90.0% in dogs with naturally induced estrus.

반도체광증폭기로 전송거리 확장된 2.5 Gb/s TDM-PON에서 버스트 효과에 의한 신호왜곡 분석 (The Burst Effect Analysis of 2.5 Gb/s TDM-PON Systems Using a SOA Link Extender)

  • 최보훈;이상수
    • 한국광학회지
    • /
    • 제23권1호
    • /
    • pp.6-11
    • /
    • 2012
  • 256개의 ONU를 수용하며 50 km 전송거리를 갖는 차세대 시분할 수동광망(TDM-PON) 링크에 링크 확장기로 반도체 광증폭기가 적용되었다. 이 광증폭기의 이득은 25dB 였고 입력신호 변화에 따른 이득 자동조정장치는 사용되지 않았다. 상향 링크의 전체 광세기 범위는 58 dB 였고, 광증폭기로의 입력신호가 -30 dBm인 조건에서 링크의 $10^{-9}$ BER을 위한 수신감도는 -25 dBm였다. 그 입력세기가 -10 dBm인 경우 버스트 신호에 의한 증폭기의 이득 과도응답에 의한 초과펄스왜곡은 45% 였고 이로 인한 신호성능의 악화는 $10^{-12}$ BER 에서 1.55 dB의 페널티를 발생시켰다. 그러나 -15 dBm 이하의 입력조건에서는 페널티는 무시할 수준으로 급격히 낮아져서, 링크의 다이나믹 범위가 최소한 -15 dBm 까지는 보장되었다. 이 같이 측정된 입력신호의 다이나믹 범위는 50 km이상 장거리 그리고 수백개 이상의 다수가입자를 지원하는 차세대 수동광망에서 링크 확장기로 광증폭기가 사용되더라도 광증폭기 이득 자동조정장치를 사용하는 것이 필수적이지 않음을 의미한다.

돼지인공수정용 정액액상보존제 Kp 의 개발에 관한 연구 I. Kp 의 pH 조절과 냉동정자에 의한 보존성 검정 (A Study on Development of Boar Semen Extender Kp for Swine AI I. Stabilization of pH Change and In Vitro Survival of Frozen-Thawed Boar Sperm in Kp Extender)

  • 김선의;정구민;서동삼;김득중;김인철;김현종;신영수;임경순
    • 한국가축번식학회지
    • /
    • 제22권4호
    • /
    • pp.405-410
    • /
    • 1998
  • 본 연구는 독자 개발한 돼지액상정액희석제 Kp(한국생명과학연구소)에 pH를 안정화하여 보존 중 정자의 운동성을 유지시킬 수 있도록 EDTA, Tris, Citrate buffer의 적정 첨가농도를 결정하고자 실시하였다. Basic Kp와 BTS (Mini-tube, Germany; BT-Sg), BTS (Tri-bio, USA; BTSa), Modena (SGI, USA)를 17$^{\circ}C$ 에서 각각 보관한 경우 모든 희석액에서 시간 경과에 따라 pH가 증가하였고, Basic Kp 는 희석 당일의 pH가 다른 희석액에 비해 높게 나타났는데 이것은 돼지액상정액의 생리적인 pH인 6.8~7.5에 비해서도 높은 수준이었다. 정액내의 pH 저하를 방지해 주고 정액의 생리적인 pH를 유지하기 위하여 Basic Kp에 EDTA, Tris, Citrate buffer를 단계적으로 첨가하면서 시간 경과에 따른 pH 변화를 살펴 본 결과 1.25g /L EDTA, 1.42g /L Tris, 1.00g /L Citrate를 첨가한 경우 (Modified Kp) pH는 l일째 6.88에서 6일째 7.33으로 유지되었다. 특히, Modified Kp에 첨가된 buffer 의 농도는 Modena와 다른 희석제에 첨가된 농도에 비해 1/2 에서 1/4 정도로 낮은 수준이었다. Modified Kp 와 Basic Kp, BTSg, BTSa 및 Modena로 냉동-융해된 돼지 정자를 희석하여 보존한 경우 정자의 운동성은 Modified Kp가 다른 희석액에 비해 유의하게 높게 나타났다(87.0% vs. 71.0~48.0% in day 1; 13.3% vs. 6.3~0% of day 6), 이상의 결과를 종합해 볼 때, Modified Kp는 낮은 농도의 EDTA, Tris, Citrate buffer 첨가에도 불구하고 돼지정자의 생리적인 pH 수준을 잘 유지할 수 있었으며, 수입되어 냉동-융해된 돼지 정자에 사용하는 희석제 BTSg, BTSa, Modena 보다도 정자의 운동성에 효과적이었다.

  • PDF